脉搏容积描记仪在预测腰麻剖宫产患者低血压中的作用

S. Desai
{"title":"脉搏容积描记仪在预测腰麻剖宫产患者低血压中的作用","authors":"S. Desai","doi":"10.26611/10151936","DOIUrl":null,"url":null,"abstract":"Background: Spinal anesthesia is a commonly employed technique for anesthesia for caesarean section and is associated with hypotension which may cause maternal morbidity. Prediction of hypotension before the procedure can reduce complications. The study aimed to evaluate the role of pulse plethysmograph in the prediction of hypotension in caesarean section patients under spinal anesthesia. Methods: The observational study was conducted on 50 patients who were undergoing emergency or elective caesarean section. Spinal anesthesia was performed by anaesthesiologist using a 25 or 26-gauge spinal needle with bupivacaine at L3-4 interspinous space. Pre and post-anesthesia observations such as the width of pulse plethysmograph, non-invasive blood pressure in another arm, and heart rate were recorded. Paired T-test, Wilcoxon sign rank test, and chi-square test was used to analyse data using R Studio V 1.2.5001 software. Results: Post spinal anesthesia minor fall in systolic blood pressure (SBP) was observed in 11 patients, moderate fall in 21 patients, severe fall in 8 patients and a massive fall in 10 patients. A significant difference was observed between mean pre- and post-spinal anesthesia SBP (P<0.001). Width of pulse plethysmograph (PPG) was maintained in 14 patients whereas, narrowed and significantly narrowed PPGs were observed in 29 and 7 patients, respectively. Significant association was observed between grades of SBP and width of PPG (P<0.05). Receiver operating characteristic curve showed the width of PGG was good for prediction of hypotension in patient (AUC=0.828). Conclusion: Width of PPG can be used to predict SA induced maternal hypotension.","PeriodicalId":18595,"journal":{"name":"MedPulse International Journal of Anesthesiology","volume":"67 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Role of pulse plethysmograph in the prediction of hypotension in caesarean section patient under spinal anesthesia\",\"authors\":\"S. Desai\",\"doi\":\"10.26611/10151936\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: Spinal anesthesia is a commonly employed technique for anesthesia for caesarean section and is associated with hypotension which may cause maternal morbidity. Prediction of hypotension before the procedure can reduce complications. The study aimed to evaluate the role of pulse plethysmograph in the prediction of hypotension in caesarean section patients under spinal anesthesia. Methods: The observational study was conducted on 50 patients who were undergoing emergency or elective caesarean section. Spinal anesthesia was performed by anaesthesiologist using a 25 or 26-gauge spinal needle with bupivacaine at L3-4 interspinous space. Pre and post-anesthesia observations such as the width of pulse plethysmograph, non-invasive blood pressure in another arm, and heart rate were recorded. Paired T-test, Wilcoxon sign rank test, and chi-square test was used to analyse data using R Studio V 1.2.5001 software. Results: Post spinal anesthesia minor fall in systolic blood pressure (SBP) was observed in 11 patients, moderate fall in 21 patients, severe fall in 8 patients and a massive fall in 10 patients. A significant difference was observed between mean pre- and post-spinal anesthesia SBP (P<0.001). Width of pulse plethysmograph (PPG) was maintained in 14 patients whereas, narrowed and significantly narrowed PPGs were observed in 29 and 7 patients, respectively. Significant association was observed between grades of SBP and width of PPG (P<0.05). Receiver operating characteristic curve showed the width of PGG was good for prediction of hypotension in patient (AUC=0.828). Conclusion: Width of PPG can be used to predict SA induced maternal hypotension.\",\"PeriodicalId\":18595,\"journal\":{\"name\":\"MedPulse International Journal of Anesthesiology\",\"volume\":\"67 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"MedPulse International Journal of Anesthesiology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.26611/10151936\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"MedPulse International Journal of Anesthesiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.26611/10151936","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

背景:腰麻是剖宫产术中常用的麻醉方法,腰麻伴有低血压,可引起产妇发病。在手术前预测低血压可以减少并发症。本研究旨在评估脉搏容积描记仪在预测脊柱麻醉下剖宫产患者低血压中的作用。方法:对50例急诊或择期剖宫产患者进行观察性研究。脊髓麻醉由麻醉师在L3-4棘间隙使用25或26号脊髓针加布比卡因进行。记录麻醉前和麻醉后的脉搏宽度、另一只手臂的无创血压、心率等观察结果。采用配对t检验、Wilcoxon符号秩检验和卡方检验,采用R Studio V 1.2.5001软件进行数据分析。结果:腰麻后收缩压轻度下降11例,中度下降21例,重度下降8例,大幅下降10例。脊髓麻醉前后平均收缩压差异有统计学意义(P<0.001)。14例患者脉搏体积描记仪(PPG)保持宽度,29例和7例患者PPG变窄和明显变窄。收缩压分级与PPG宽度有显著相关性(P<0.05)。受试者工作特征曲线显示PGG宽度较好预测患者低血压(AUC=0.828)。结论:PPG宽度可用于预测SA诱发的低血压。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Role of pulse plethysmograph in the prediction of hypotension in caesarean section patient under spinal anesthesia
Background: Spinal anesthesia is a commonly employed technique for anesthesia for caesarean section and is associated with hypotension which may cause maternal morbidity. Prediction of hypotension before the procedure can reduce complications. The study aimed to evaluate the role of pulse plethysmograph in the prediction of hypotension in caesarean section patients under spinal anesthesia. Methods: The observational study was conducted on 50 patients who were undergoing emergency or elective caesarean section. Spinal anesthesia was performed by anaesthesiologist using a 25 or 26-gauge spinal needle with bupivacaine at L3-4 interspinous space. Pre and post-anesthesia observations such as the width of pulse plethysmograph, non-invasive blood pressure in another arm, and heart rate were recorded. Paired T-test, Wilcoxon sign rank test, and chi-square test was used to analyse data using R Studio V 1.2.5001 software. Results: Post spinal anesthesia minor fall in systolic blood pressure (SBP) was observed in 11 patients, moderate fall in 21 patients, severe fall in 8 patients and a massive fall in 10 patients. A significant difference was observed between mean pre- and post-spinal anesthesia SBP (P<0.001). Width of pulse plethysmograph (PPG) was maintained in 14 patients whereas, narrowed and significantly narrowed PPGs were observed in 29 and 7 patients, respectively. Significant association was observed between grades of SBP and width of PPG (P<0.05). Receiver operating characteristic curve showed the width of PGG was good for prediction of hypotension in patient (AUC=0.828). Conclusion: Width of PPG can be used to predict SA induced maternal hypotension.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信