中性pH条件下ptni修饰掺硼金刚石中Pt-Ni沉积顺序对葡萄糖氧化催化性能的影响

Ruitong Zhu, Zihua Zhao, Jun Cao, Haichao Li, Li Ma, K. Zhou, Zhiming Yu, Qiu-ping Wei
{"title":"中性pH条件下ptni修饰掺硼金刚石中Pt-Ni沉积顺序对葡萄糖氧化催化性能的影响","authors":"Ruitong Zhu, Zihua Zhao, Jun Cao, Haichao Li, Li Ma, K. Zhou, Zhiming Yu, Qiu-ping Wei","doi":"10.2139/ssrn.3920309","DOIUrl":null,"url":null,"abstract":"With the increasing number of diabetic patients, considerable attention has been paid to developing metal nanomaterial glucose sensors for detecting under physiological pH conditions. In this work, Pt-Ni modified boron-doped diamond (BDD) electrodes were fabricated and achieved a continuous and stable response to glucose under neutral pH conditions. Besides, effects of the electrochemical deposition sequence on the morphology and electrocatalytic properties of the Pt-Ni bimetal had been found. Electrochemical performance tests showed that the Pt-Ni bimetal clusters prepared by the co-deposition (one step) method had higher stability and sensitivity for the glucose detection than those prepared by the two-step deposition method. The loss of the oxidation peak current of PtNi-BDD is 21.74% after 200 consecutive cyclic voltammetry cycles (2400 s). While Ni/Pt-BDD and Pt-BDD only maintained 55.8% and 60.03% of their initial current response after continuous 1200 s cyclic voltammetry. In addition, the sensitivity of PtNi-BDD was 110.375 μA cm -1 mm -1 in the range of 2-12 mM glucose concentration, which was 5.966, 15.49, and 6.13 times higher than that of Pt/Ni-BDD, Ni/Pt-BDD, and single metal Pt, respectively.","PeriodicalId":18268,"journal":{"name":"Materials Engineering eJournal","volume":"71 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effect of Pt-Ni Deposition Sequence in PtNi-Modified Boron-Doped Diamond on Catalytic Performance for Glucose Oxidation Under Neutral pH Conditions\",\"authors\":\"Ruitong Zhu, Zihua Zhao, Jun Cao, Haichao Li, Li Ma, K. Zhou, Zhiming Yu, Qiu-ping Wei\",\"doi\":\"10.2139/ssrn.3920309\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"With the increasing number of diabetic patients, considerable attention has been paid to developing metal nanomaterial glucose sensors for detecting under physiological pH conditions. In this work, Pt-Ni modified boron-doped diamond (BDD) electrodes were fabricated and achieved a continuous and stable response to glucose under neutral pH conditions. Besides, effects of the electrochemical deposition sequence on the morphology and electrocatalytic properties of the Pt-Ni bimetal had been found. Electrochemical performance tests showed that the Pt-Ni bimetal clusters prepared by the co-deposition (one step) method had higher stability and sensitivity for the glucose detection than those prepared by the two-step deposition method. The loss of the oxidation peak current of PtNi-BDD is 21.74% after 200 consecutive cyclic voltammetry cycles (2400 s). While Ni/Pt-BDD and Pt-BDD only maintained 55.8% and 60.03% of their initial current response after continuous 1200 s cyclic voltammetry. In addition, the sensitivity of PtNi-BDD was 110.375 μA cm -1 mm -1 in the range of 2-12 mM glucose concentration, which was 5.966, 15.49, and 6.13 times higher than that of Pt/Ni-BDD, Ni/Pt-BDD, and single metal Pt, respectively.\",\"PeriodicalId\":18268,\"journal\":{\"name\":\"Materials Engineering eJournal\",\"volume\":\"71 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Materials Engineering eJournal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2139/ssrn.3920309\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Materials Engineering eJournal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2139/ssrn.3920309","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

随着糖尿病患者数量的不断增加,开发用于生理pH条件下检测的金属纳米材料葡萄糖传感器备受关注。在这项工作中,制备了Pt-Ni修饰的掺硼金刚石(BDD)电极,并在中性pH条件下实现了对葡萄糖的连续稳定响应。此外,还发现了电化学沉积顺序对Pt-Ni双金属形貌和电催化性能的影响。电化学性能测试表明,一步共沉积法制备的Pt-Ni双金属团簇比两步共沉积法制备的Pt-Ni双金属团簇具有更高的葡萄糖检测稳定性和灵敏度。连续200次循环伏安(2400 s)后,PtNi-BDD氧化峰电流损失21.74%,而连续1200 s循环伏安后,Ni/Pt-BDD和Pt-BDD氧化峰电流仅维持初始电流响应的55.8%和60.03%。在2 ~ 12 mm葡萄糖浓度范围内,PtNi-BDD的灵敏度为110.375 μA cm -1 mm -1,分别是Pt/Ni- bdd、Ni/Pt- bdd和单金属Pt的5.966、15.49和6.13倍。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Effect of Pt-Ni Deposition Sequence in PtNi-Modified Boron-Doped Diamond on Catalytic Performance for Glucose Oxidation Under Neutral pH Conditions
With the increasing number of diabetic patients, considerable attention has been paid to developing metal nanomaterial glucose sensors for detecting under physiological pH conditions. In this work, Pt-Ni modified boron-doped diamond (BDD) electrodes were fabricated and achieved a continuous and stable response to glucose under neutral pH conditions. Besides, effects of the electrochemical deposition sequence on the morphology and electrocatalytic properties of the Pt-Ni bimetal had been found. Electrochemical performance tests showed that the Pt-Ni bimetal clusters prepared by the co-deposition (one step) method had higher stability and sensitivity for the glucose detection than those prepared by the two-step deposition method. The loss of the oxidation peak current of PtNi-BDD is 21.74% after 200 consecutive cyclic voltammetry cycles (2400 s). While Ni/Pt-BDD and Pt-BDD only maintained 55.8% and 60.03% of their initial current response after continuous 1200 s cyclic voltammetry. In addition, the sensitivity of PtNi-BDD was 110.375 μA cm -1 mm -1 in the range of 2-12 mM glucose concentration, which was 5.966, 15.49, and 6.13 times higher than that of Pt/Ni-BDD, Ni/Pt-BDD, and single metal Pt, respectively.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信