基于对氨基苯基乙酸接枝碳电极作为固定平台的粘蛋白4免疫传感器

Oana Hosu, Mihaela Tertiş, Gheorghe Melinte, Robert Săndulescu, Cecilia Cristea
{"title":"基于对氨基苯基乙酸接枝碳电极作为固定平台的粘蛋白4免疫传感器","authors":"Oana Hosu,&nbsp;Mihaela Tertiş,&nbsp;Gheorghe Melinte,&nbsp;Robert Săndulescu,&nbsp;Cecilia Cristea","doi":"10.1016/j.protcy.2017.04.048","DOIUrl":null,"url":null,"abstract":"<div><p>A simple impedimetric label-free immunosensor was developed for the specific and sensitive detection of mucin 4 (MUC 4) protein by using graphite based screen printed electrodes modified with an aryl diazonium salt or compound (<em>p</em>- aminophenylacetic acid) for the immobilization of antibody anti-MUC4 via amidic bond. Electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) were used in order to characterize and optimize the electrografting process. The parameters involved in each step of the immunosensor design were optimized. The performance of the immunoassay in terms of sensitivity, reproducibility and selectivity was studied.</p></div>","PeriodicalId":101042,"journal":{"name":"Procedia Technology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2017-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.protcy.2017.04.048","citationCount":"1","resultStr":"{\"title\":\"Mucin 4 Immunosensor Based on p-aminophenylacetic Acid Grafting on Carbon Electrodes as Immobilization Platform\",\"authors\":\"Oana Hosu,&nbsp;Mihaela Tertiş,&nbsp;Gheorghe Melinte,&nbsp;Robert Săndulescu,&nbsp;Cecilia Cristea\",\"doi\":\"10.1016/j.protcy.2017.04.048\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>A simple impedimetric label-free immunosensor was developed for the specific and sensitive detection of mucin 4 (MUC 4) protein by using graphite based screen printed electrodes modified with an aryl diazonium salt or compound (<em>p</em>- aminophenylacetic acid) for the immobilization of antibody anti-MUC4 via amidic bond. Electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) were used in order to characterize and optimize the electrografting process. The parameters involved in each step of the immunosensor design were optimized. The performance of the immunoassay in terms of sensitivity, reproducibility and selectivity was studied.</p></div>\",\"PeriodicalId\":101042,\"journal\":{\"name\":\"Procedia Technology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/j.protcy.2017.04.048\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Procedia Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S221201731730049X\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Procedia Technology","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S221201731730049X","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

采用芳基重氮盐或化合物(对氨基苯基乙酸)修饰石墨基丝网印刷电极,通过酰胺键固定抗muc4抗体,研制了一种简便的无阻抗标记免疫传感器,用于muc4蛋白的特异性和敏感性检测。利用电化学阻抗谱(EIS)和循环伏安法(CV)对电接枝工艺进行了表征和优化。对免疫传感器设计各步骤所涉及的参数进行了优化。从灵敏度、重现性和选择性等方面研究了该免疫分析法的性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Mucin 4 Immunosensor Based on p-aminophenylacetic Acid Grafting on Carbon Electrodes as Immobilization Platform

A simple impedimetric label-free immunosensor was developed for the specific and sensitive detection of mucin 4 (MUC 4) protein by using graphite based screen printed electrodes modified with an aryl diazonium salt or compound (p- aminophenylacetic acid) for the immobilization of antibody anti-MUC4 via amidic bond. Electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) were used in order to characterize and optimize the electrografting process. The parameters involved in each step of the immunosensor design were optimized. The performance of the immunoassay in terms of sensitivity, reproducibility and selectivity was studied.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信