E. Fernández, A. Loureiro, P. Rodrigo, F. Almonacid, J. I. Fernández, P. J. P. Higueras, G. Almonacid
{"title":"用Voc计算HCPV模块的电池温度","authors":"E. Fernández, A. Loureiro, P. Rodrigo, F. Almonacid, J. I. Fernández, P. J. P. Higueras, G. Almonacid","doi":"10.1109/CDE.2013.6481406","DOIUrl":null,"url":null,"abstract":"Knowledge of solar cell operating temperature is critical to evaluate the energy performance of a HCPV module. However, the measurement of the cell temperature in HCPV modules is a very complex task due to the special features of these types of modules, so it is useful to find indirect methods to calculate this. DNI, cell temperature and I-V curves have been measured for one year in the Centre of Advanced Studies in Energy and Environment of the University of Jaen located in the south of Spain. Thanks to these measurements, cell temperature can be determinate as a function of Voc with a mean relative error of -0.38 %.","PeriodicalId":6614,"journal":{"name":"2013 Spanish Conference on Electron Devices","volume":"220 1","pages":"317-320"},"PeriodicalIF":0.0000,"publicationDate":"2013-03-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"10","resultStr":"{\"title\":\"Calculation of cell temperature in a HCPV module using Voc\",\"authors\":\"E. Fernández, A. Loureiro, P. Rodrigo, F. Almonacid, J. I. Fernández, P. J. P. Higueras, G. Almonacid\",\"doi\":\"10.1109/CDE.2013.6481406\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Knowledge of solar cell operating temperature is critical to evaluate the energy performance of a HCPV module. However, the measurement of the cell temperature in HCPV modules is a very complex task due to the special features of these types of modules, so it is useful to find indirect methods to calculate this. DNI, cell temperature and I-V curves have been measured for one year in the Centre of Advanced Studies in Energy and Environment of the University of Jaen located in the south of Spain. Thanks to these measurements, cell temperature can be determinate as a function of Voc with a mean relative error of -0.38 %.\",\"PeriodicalId\":6614,\"journal\":{\"name\":\"2013 Spanish Conference on Electron Devices\",\"volume\":\"220 1\",\"pages\":\"317-320\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-03-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 Spanish Conference on Electron Devices\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CDE.2013.6481406\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 Spanish Conference on Electron Devices","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CDE.2013.6481406","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Calculation of cell temperature in a HCPV module using Voc
Knowledge of solar cell operating temperature is critical to evaluate the energy performance of a HCPV module. However, the measurement of the cell temperature in HCPV modules is a very complex task due to the special features of these types of modules, so it is useful to find indirect methods to calculate this. DNI, cell temperature and I-V curves have been measured for one year in the Centre of Advanced Studies in Energy and Environment of the University of Jaen located in the south of Spain. Thanks to these measurements, cell temperature can be determinate as a function of Voc with a mean relative error of -0.38 %.