湿度对定子绕组局部放电活动影响的实例研究

G. Stone, V. Warren, M. Fenger
{"title":"湿度对定子绕组局部放电活动影响的实例研究","authors":"G. Stone, V. Warren, M. Fenger","doi":"10.1109/ELINSL.2002.996005","DOIUrl":null,"url":null,"abstract":"Online partial discharge testing has long been used to assess the condition of the high-voltage insulation in motor and generator stator windings. Past research has shown that motor and generator operating parameters such as voltage, power output, gas pressure, and stator winding temperature can have an important impact on the PD levels, and thus must be controlled if useful trends in PD activity over time are to be obtained. Over the years, results have been collected that indicate humidity may also be a factor that needs to be monitored. In addition, some simple laboratory experiments have been performed to verify that humidity can change the PD. When applying online PD testing to assess stator winding insulation condition, users must be aware of the influence of humidity on the measured PD activity to properly interpret the results.","PeriodicalId":10532,"journal":{"name":"Conference Record of the the 2002 IEEE International Symposium on Electrical Insulation (Cat. No.02CH37316)","volume":"36 1","pages":"579-581"},"PeriodicalIF":0.0000,"publicationDate":"2002-04-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Case studies on the effect of humidity on stator winding partial discharge activity\",\"authors\":\"G. Stone, V. Warren, M. Fenger\",\"doi\":\"10.1109/ELINSL.2002.996005\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Online partial discharge testing has long been used to assess the condition of the high-voltage insulation in motor and generator stator windings. Past research has shown that motor and generator operating parameters such as voltage, power output, gas pressure, and stator winding temperature can have an important impact on the PD levels, and thus must be controlled if useful trends in PD activity over time are to be obtained. Over the years, results have been collected that indicate humidity may also be a factor that needs to be monitored. In addition, some simple laboratory experiments have been performed to verify that humidity can change the PD. When applying online PD testing to assess stator winding insulation condition, users must be aware of the influence of humidity on the measured PD activity to properly interpret the results.\",\"PeriodicalId\":10532,\"journal\":{\"name\":\"Conference Record of the the 2002 IEEE International Symposium on Electrical Insulation (Cat. No.02CH37316)\",\"volume\":\"36 1\",\"pages\":\"579-581\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2002-04-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Conference Record of the the 2002 IEEE International Symposium on Electrical Insulation (Cat. No.02CH37316)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ELINSL.2002.996005\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Conference Record of the the 2002 IEEE International Symposium on Electrical Insulation (Cat. No.02CH37316)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ELINSL.2002.996005","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

长期以来,在线局部放电测试一直被用于评估电机和发电机定子绕组的高压绝缘状况。过去的研究表明,电机和发电机的运行参数,如电压、功率输出、气体压力和定子绕组温度,对局部放电水平有重要影响,因此,如果要获得局部放电活动随时间的有用趋势,必须对其进行控制。多年来,收集的结果表明,湿度也可能是一个需要监测的因素。此外,还进行了一些简单的实验室实验来验证湿度可以改变PD。当应用在线局部放电测试来评估定子绕组绝缘状况时,用户必须意识到湿度对测量的局部放电活动的影响,以便正确解释结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Case studies on the effect of humidity on stator winding partial discharge activity
Online partial discharge testing has long been used to assess the condition of the high-voltage insulation in motor and generator stator windings. Past research has shown that motor and generator operating parameters such as voltage, power output, gas pressure, and stator winding temperature can have an important impact on the PD levels, and thus must be controlled if useful trends in PD activity over time are to be obtained. Over the years, results have been collected that indicate humidity may also be a factor that needs to be monitored. In addition, some simple laboratory experiments have been performed to verify that humidity can change the PD. When applying online PD testing to assess stator winding insulation condition, users must be aware of the influence of humidity on the measured PD activity to properly interpret the results.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信