基于Matlab/Simulink的电弧炉配电系统电能质量问题及有源滤波器缓解方案

Ngo Van Thai, B. Q. Khanh
{"title":"基于Matlab/Simulink的电弧炉配电系统电能质量问题及有源滤波器缓解方案","authors":"Ngo Van Thai, B. Q. Khanh","doi":"10.51316/jst.159.etsd.2022.32.3.10","DOIUrl":null,"url":null,"abstract":"The non-linearity of the conductance of the electric arc furnace causes voltage flicker and harmonics in power systems. Nowadays, the application of electric arc furnaces in the steel production industry in Vietnam also results in the aforementioned power quality issues and it has been critical to find appropriate solutions for mitigation of those issues recently. This paper develops a time-domain simulation of electric arc furnace that can show power quality issues such as voltage flicker and harmonics in the distribution system and the solution using an active filter for power quality improvement in MATLAB/SIMULINK and thus, it is possible to assess the influences of different parameters of electric arc furnace on the design of active filter. The comparison of simulation results and experimental results obtained from the distribution system of the factory of Thien Phat Company has been conducted.","PeriodicalId":17641,"journal":{"name":"JST: Engineering and Technology for Sustainable Development","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"On a Matlab/Simulink of Power Quality Issues in Distribution System with the Presence of Electric Arc Furnaces and Mitigation Solution Using Active Filter\",\"authors\":\"Ngo Van Thai, B. Q. Khanh\",\"doi\":\"10.51316/jst.159.etsd.2022.32.3.10\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The non-linearity of the conductance of the electric arc furnace causes voltage flicker and harmonics in power systems. Nowadays, the application of electric arc furnaces in the steel production industry in Vietnam also results in the aforementioned power quality issues and it has been critical to find appropriate solutions for mitigation of those issues recently. This paper develops a time-domain simulation of electric arc furnace that can show power quality issues such as voltage flicker and harmonics in the distribution system and the solution using an active filter for power quality improvement in MATLAB/SIMULINK and thus, it is possible to assess the influences of different parameters of electric arc furnace on the design of active filter. The comparison of simulation results and experimental results obtained from the distribution system of the factory of Thien Phat Company has been conducted.\",\"PeriodicalId\":17641,\"journal\":{\"name\":\"JST: Engineering and Technology for Sustainable Development\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-07-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"JST: Engineering and Technology for Sustainable Development\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.51316/jst.159.etsd.2022.32.3.10\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"JST: Engineering and Technology for Sustainable Development","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.51316/jst.159.etsd.2022.32.3.10","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

电弧炉电导的非线性会引起电力系统的电压闪变和谐波。如今,电弧炉在越南钢铁生产行业的应用也导致了上述电能质量问题,最近找到适当的解决办法来缓解这些问题至关重要。本文在MATLAB/SIMULINK中开发了一个电弧炉时域仿真系统,可以显示配电系统中电压闪变、谐波等电能质量问题,并利用有源滤波器改善电能质量,从而可以评估电弧炉不同参数对有源滤波器设计的影响。将仿真结果与天发公司工厂配电系统的实验结果进行了比较。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
On a Matlab/Simulink of Power Quality Issues in Distribution System with the Presence of Electric Arc Furnaces and Mitigation Solution Using Active Filter
The non-linearity of the conductance of the electric arc furnace causes voltage flicker and harmonics in power systems. Nowadays, the application of electric arc furnaces in the steel production industry in Vietnam also results in the aforementioned power quality issues and it has been critical to find appropriate solutions for mitigation of those issues recently. This paper develops a time-domain simulation of electric arc furnace that can show power quality issues such as voltage flicker and harmonics in the distribution system and the solution using an active filter for power quality improvement in MATLAB/SIMULINK and thus, it is possible to assess the influences of different parameters of electric arc furnace on the design of active filter. The comparison of simulation results and experimental results obtained from the distribution system of the factory of Thien Phat Company has been conducted.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信