爱丽丝:贝西二号软x射线共振磁散射衍射/反射仪

R. Abrudan, F. Radu
{"title":"爱丽丝:贝西二号软x射线共振磁散射衍射/反射仪","authors":"R. Abrudan, F. Radu","doi":"10.17815/JLSRF-2-83","DOIUrl":null,"url":null,"abstract":"Although the chamber named ALICE was designed for the analysis of magnetic hetero- and nanostructures via resonant magnetic x-ray scattering, the instrument is not limited to this technique. Static measurements involve the possibility to use scattering and spectroscopy synchrotron based techniques (photon-in photon-out, photon-in electron-out, and coherent scattering). Dynamic experiments require either laser or magnetic field pulses to excite the spin system followed by x-ray probe in the time domain from nano- to femtosecond delay times. In this temporal range, the demagnetization/remagnetization dynamics and magnetization precession in a number of magnetic materials (metals, alloys, and magnetic multilayers) can be probed in an element specific manner. The versatility of the instrument was tested by a series of pilot experiments, pointing out ALICE as one of the most demanded instruments at the Helmholtz-Zentrum in Berlin.","PeriodicalId":16282,"journal":{"name":"Journal of large-scale research facilities JLSRF","volume":"4 1","pages":"69"},"PeriodicalIF":0.0000,"publicationDate":"2016-05-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"ALICE: A diffractometer/reflectometer for soft X-ray resonant magnetic scattering at BESSY II\",\"authors\":\"R. Abrudan, F. Radu\",\"doi\":\"10.17815/JLSRF-2-83\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Although the chamber named ALICE was designed for the analysis of magnetic hetero- and nanostructures via resonant magnetic x-ray scattering, the instrument is not limited to this technique. Static measurements involve the possibility to use scattering and spectroscopy synchrotron based techniques (photon-in photon-out, photon-in electron-out, and coherent scattering). Dynamic experiments require either laser or magnetic field pulses to excite the spin system followed by x-ray probe in the time domain from nano- to femtosecond delay times. In this temporal range, the demagnetization/remagnetization dynamics and magnetization precession in a number of magnetic materials (metals, alloys, and magnetic multilayers) can be probed in an element specific manner. The versatility of the instrument was tested by a series of pilot experiments, pointing out ALICE as one of the most demanded instruments at the Helmholtz-Zentrum in Berlin.\",\"PeriodicalId\":16282,\"journal\":{\"name\":\"Journal of large-scale research facilities JLSRF\",\"volume\":\"4 1\",\"pages\":\"69\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-05-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of large-scale research facilities JLSRF\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.17815/JLSRF-2-83\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of large-scale research facilities JLSRF","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17815/JLSRF-2-83","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

虽然这个名为ALICE的腔室是为通过共振磁x射线散射分析磁性异质和纳米结构而设计的,但该仪器并不局限于这项技术。静态测量包括使用基于同步加速器的散射和光谱学技术的可能性(光子进光子出,光子进电子出和相干散射)。动态实验需要激光或磁场脉冲激发自旋系统,然后x射线探针在时域内从纳秒到飞秒的延迟时间。在这个时间范围内,许多磁性材料(金属、合金和磁性多层材料)的退磁/再磁化动力学和磁化进动可以用特定元素的方式进行探测。该仪器的多功能性通过一系列试点实验进行了测试,指出ALICE是柏林亥姆霍兹中心最需要的仪器之一。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
ALICE: A diffractometer/reflectometer for soft X-ray resonant magnetic scattering at BESSY II
Although the chamber named ALICE was designed for the analysis of magnetic hetero- and nanostructures via resonant magnetic x-ray scattering, the instrument is not limited to this technique. Static measurements involve the possibility to use scattering and spectroscopy synchrotron based techniques (photon-in photon-out, photon-in electron-out, and coherent scattering). Dynamic experiments require either laser or magnetic field pulses to excite the spin system followed by x-ray probe in the time domain from nano- to femtosecond delay times. In this temporal range, the demagnetization/remagnetization dynamics and magnetization precession in a number of magnetic materials (metals, alloys, and magnetic multilayers) can be probed in an element specific manner. The versatility of the instrument was tested by a series of pilot experiments, pointing out ALICE as one of the most demanded instruments at the Helmholtz-Zentrum in Berlin.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信