铁的质量平衡研究无需使用大样本中子活化分析进行次取样

T. Yagob, P. Bode, A. Wiel, H. Wolterbeek
{"title":"铁的质量平衡研究无需使用大样本中子活化分析进行次取样","authors":"T. Yagob, P. Bode, A. Wiel, H. Wolterbeek","doi":"10.19112/2413-6174-2017-18-2-28-33","DOIUrl":null,"url":null,"abstract":"Accurate assessments of the iron (Fe) intake from food is mandatory for mass balance studies. The reliability of such assessments is strongly dependent on the representativeness of the analytical test portion and, as such, the quality of the homogenization of the double portions collected. Large sample Instrumental Neutron Activation Analysis (INAA) circumvents these problems as the entire double portions can be analysed without homogenization. Fe was measured both in approximately 1 kg freeze-dried food as well as in moist products. A (commercially available) porridge fine wheat grain was used as a reference sample (assumed to be homogeneous in the Fe content). The amount of iron in the fine wheat grain was also measured using small sample INAA. The moisture content of the fresh food did not cause any problem during the irradiation such radiolysis and excessive gas formation due to low radiation dose during the irradiation. The results obtained for the moist sample were statistically equivalent to those found for the dried sample ( 73.1± 4, 74± 3 mg/kg respectively, zeta (ζ ) score = 0.18) . The applicability of LS-NAA was further illustrated by measurement of Fe in commercially available microwave meals which was found to be 30±2 mg/kg. Large Sample INAA is a novel and attractive approach for measurement of element content of the dietary intake by the double portion technique collected during 5-7 day in mass balance experiments. Similarly, it can be directly applied without sample preparation for the analysis of faeces collected in such studies.","PeriodicalId":23176,"journal":{"name":"Trace elements in medicine","volume":"1 1","pages":"28-33"},"PeriodicalIF":0.0000,"publicationDate":"2018-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Mass balance studies of iron without the need of subsampling using large sample neutron activation analysis\",\"authors\":\"T. Yagob, P. Bode, A. Wiel, H. Wolterbeek\",\"doi\":\"10.19112/2413-6174-2017-18-2-28-33\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Accurate assessments of the iron (Fe) intake from food is mandatory for mass balance studies. The reliability of such assessments is strongly dependent on the representativeness of the analytical test portion and, as such, the quality of the homogenization of the double portions collected. Large sample Instrumental Neutron Activation Analysis (INAA) circumvents these problems as the entire double portions can be analysed without homogenization. Fe was measured both in approximately 1 kg freeze-dried food as well as in moist products. A (commercially available) porridge fine wheat grain was used as a reference sample (assumed to be homogeneous in the Fe content). The amount of iron in the fine wheat grain was also measured using small sample INAA. The moisture content of the fresh food did not cause any problem during the irradiation such radiolysis and excessive gas formation due to low radiation dose during the irradiation. The results obtained for the moist sample were statistically equivalent to those found for the dried sample ( 73.1± 4, 74± 3 mg/kg respectively, zeta (ζ ) score = 0.18) . The applicability of LS-NAA was further illustrated by measurement of Fe in commercially available microwave meals which was found to be 30±2 mg/kg. Large Sample INAA is a novel and attractive approach for measurement of element content of the dietary intake by the double portion technique collected during 5-7 day in mass balance experiments. Similarly, it can be directly applied without sample preparation for the analysis of faeces collected in such studies.\",\"PeriodicalId\":23176,\"journal\":{\"name\":\"Trace elements in medicine\",\"volume\":\"1 1\",\"pages\":\"28-33\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Trace elements in medicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.19112/2413-6174-2017-18-2-28-33\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Trace elements in medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.19112/2413-6174-2017-18-2-28-33","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

准确评估从食物中摄取的铁(Fe)是质量平衡研究的必要条件。这种评估的可靠性在很大程度上取决于分析测试部分的代表性,因此,收集的双部分均质化的质量。大样本仪器中子活化分析(INAA)避免了这些问题,因为整个双组分可以在没有均质化的情况下进行分析。在大约1公斤的冻干食品和潮湿产品中都测量了铁。以A(市售)粥状细麦粒作为参比样品(假定铁含量均匀)。用小样本INAA法测定了细粒小麦中铁的含量。在辐照过程中,由于辐照剂量低,鲜食材的水分含量没有出现辐射分解和气体过量等问题。湿润样品的结果与干燥样品的结果在统计学上相当(分别为73.1±4,74±3 mg/kg, ζ (ζ)评分= 0.18)。LS-NAA在市售微波食品中的铁含量为30±2 mg/kg,进一步证明了其适用性。大样本INAA是一种新颖而有吸引力的方法,可以通过在质量平衡实验中收集5-7天的双分量技术来测量膳食摄入中的元素含量。同样,它可以直接应用于这些研究中收集的粪便的分析,而不需要准备样品。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Mass balance studies of iron without the need of subsampling using large sample neutron activation analysis
Accurate assessments of the iron (Fe) intake from food is mandatory for mass balance studies. The reliability of such assessments is strongly dependent on the representativeness of the analytical test portion and, as such, the quality of the homogenization of the double portions collected. Large sample Instrumental Neutron Activation Analysis (INAA) circumvents these problems as the entire double portions can be analysed without homogenization. Fe was measured both in approximately 1 kg freeze-dried food as well as in moist products. A (commercially available) porridge fine wheat grain was used as a reference sample (assumed to be homogeneous in the Fe content). The amount of iron in the fine wheat grain was also measured using small sample INAA. The moisture content of the fresh food did not cause any problem during the irradiation such radiolysis and excessive gas formation due to low radiation dose during the irradiation. The results obtained for the moist sample were statistically equivalent to those found for the dried sample ( 73.1± 4, 74± 3 mg/kg respectively, zeta (ζ ) score = 0.18) . The applicability of LS-NAA was further illustrated by measurement of Fe in commercially available microwave meals which was found to be 30±2 mg/kg. Large Sample INAA is a novel and attractive approach for measurement of element content of the dietary intake by the double portion technique collected during 5-7 day in mass balance experiments. Similarly, it can be directly applied without sample preparation for the analysis of faeces collected in such studies.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信