基于正电子发射断层扫描仪正电子学的研究进展

N. Nohara
{"title":"基于正电子发射断层扫描仪正电子学的研究进展","authors":"N. Nohara","doi":"10.11323/jjmp.42.1_23","DOIUrl":null,"url":null,"abstract":"This article gives a commentary on the development of positron emission tomography scanners based on Positology which was proposed by Dr. Eiichi Tanaka. Circular detector rings of an equally spaced detector arrangement have a problem of linear sampling density distributions in the projections. The problem can be solved by Positology in which a continuously rotating detector ring of an unequally spaced detector arrangement obtained by computer iterative searching provides a fine and uniform sampling density distribution. The imaging performance of multilayer positron emission tomography scanners for extended sources is evaluated analytically. The analysis is simplified by \"rotation transform,\" by which three-dimensional photon detection problems are solved by two-dimensional treatment. Event rates of singles, unscattered true coincidence, and single- and double-scattered coincidence are formulated for a uniform cylindrical phantom. Positron emission tomography scanners based on Positology, named Positologica, were developed for brain, whole-body and animal study. A high resolution stationary PET scanner, SHR-1200 was also developed for brain study.","PeriodicalId":13394,"journal":{"name":"Igaku butsuri : Nihon Igaku Butsuri Gakkai kikanshi = Japanese journal of medical physics : an official journal of Japan Society of Medical Physics","volume":"54 1","pages":"23-32"},"PeriodicalIF":0.0000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Development of Positron Emission Tomography Scanners Based on Positology].\",\"authors\":\"N. Nohara\",\"doi\":\"10.11323/jjmp.42.1_23\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This article gives a commentary on the development of positron emission tomography scanners based on Positology which was proposed by Dr. Eiichi Tanaka. Circular detector rings of an equally spaced detector arrangement have a problem of linear sampling density distributions in the projections. The problem can be solved by Positology in which a continuously rotating detector ring of an unequally spaced detector arrangement obtained by computer iterative searching provides a fine and uniform sampling density distribution. The imaging performance of multilayer positron emission tomography scanners for extended sources is evaluated analytically. The analysis is simplified by \\\"rotation transform,\\\" by which three-dimensional photon detection problems are solved by two-dimensional treatment. Event rates of singles, unscattered true coincidence, and single- and double-scattered coincidence are formulated for a uniform cylindrical phantom. Positron emission tomography scanners based on Positology, named Positologica, were developed for brain, whole-body and animal study. A high resolution stationary PET scanner, SHR-1200 was also developed for brain study.\",\"PeriodicalId\":13394,\"journal\":{\"name\":\"Igaku butsuri : Nihon Igaku Butsuri Gakkai kikanshi = Japanese journal of medical physics : an official journal of Japan Society of Medical Physics\",\"volume\":\"54 1\",\"pages\":\"23-32\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Igaku butsuri : Nihon Igaku Butsuri Gakkai kikanshi = Japanese journal of medical physics : an official journal of Japan Society of Medical Physics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.11323/jjmp.42.1_23\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Igaku butsuri : Nihon Igaku Butsuri Gakkai kikanshi = Japanese journal of medical physics : an official journal of Japan Society of Medical Physics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11323/jjmp.42.1_23","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文综述了田中荣一博士提出的基于正电子发射断层扫描仪正电子学的研究进展。等间隔探测器排列的圆形探测器环在投影中存在线性采样密度分布的问题。这一问题可以用位态学的方法来解决,通过计算机迭代搜索得到的不等间隔的连续旋转的探测器环可以提供精细均匀的采样密度分布。对扩展源多层正电子发射断层扫描仪的成像性能进行了分析评价。通过“旋转变换”简化了分析,通过旋转变换,三维光子检测问题可以通过二维处理来解决。给出了均匀圆柱形幻体的单散射、非散射真巧合、单散射和双散射巧合的事件率公式。正电子发射断层扫描仪(Positology)是基于posit的正电子发射断层扫描仪,被称为posit,用于脑、全身和动物研究。高分辨率固定式PET扫描仪shrr -1200也被开发用于脑部研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
[Development of Positron Emission Tomography Scanners Based on Positology].
This article gives a commentary on the development of positron emission tomography scanners based on Positology which was proposed by Dr. Eiichi Tanaka. Circular detector rings of an equally spaced detector arrangement have a problem of linear sampling density distributions in the projections. The problem can be solved by Positology in which a continuously rotating detector ring of an unequally spaced detector arrangement obtained by computer iterative searching provides a fine and uniform sampling density distribution. The imaging performance of multilayer positron emission tomography scanners for extended sources is evaluated analytically. The analysis is simplified by "rotation transform," by which three-dimensional photon detection problems are solved by two-dimensional treatment. Event rates of singles, unscattered true coincidence, and single- and double-scattered coincidence are formulated for a uniform cylindrical phantom. Positron emission tomography scanners based on Positology, named Positologica, were developed for brain, whole-body and animal study. A high resolution stationary PET scanner, SHR-1200 was also developed for brain study.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信