食物栅不锈钢棒用于家兔股骨横骨折内固定的利弊(综述)

H. H. Nazht
{"title":"食物栅不锈钢棒用于家兔股骨横骨折内固定的利弊(综述)","authors":"H. H. Nazht","doi":"10.23880/OAJVSR-16000198","DOIUrl":null,"url":null,"abstract":"The present study designed to focus on the advantages and disadvantages of using food grate stainless steel rods (FGSR) as internal fixation methods for induced transverse fractures in the mid shift of the femoral bones in rabbits.200 cases were collected from 2007 to 2020, all these cases were employed to induced transverse fractures in the mid shift of femoral bone, 100 of them used the rods for internal fixation, 80 of the cases used the rods for fixation the natural xenbony implantation from sheep or calves, and the others 20 cases used the rods for internal fixation of the synthetics nano bony implantation .The physical, chemical, clinical and radiographic parameters were used for evaluation, the physical and chemical analysis showed that the rods not change during sterilization, implantation or when exposed to different types of ray besides the chemical constant is about the same level measurement of the medical intramedullary pins (IMP), while the clinical observation revealed that the rods can used strongly and successfully for fracture fixation and support the animal to bear the weight, the limb used for walking gradually after 24-48 hours p. o. with some cases shown the FGSR pulled from the bone, other suffer from infection with pus formation with lateral deviation of the stifle joint or re-fracture. While the radiological finding revealed that the FGSR insert and fix the fractures fragment and the bony implantation, the pins seemed stable and fit the intramedullary canal and fracture fragments, while some cases shows that the pin not insert properly inside the femoral bone with case of multible and comminuted fractures, other case shown the FGSR pass and penetrate the stifle joint. The conclusion is, there are many advantages with minor or very little disadvantages for using the FGSR as internal fixation of the induced transverse fractures in the mid shift of the femoral bones and for natural and synthetics bony implantation in rabbits.","PeriodicalId":19494,"journal":{"name":"Open Access Journal","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Advantages and Disadvantages of using Food Grate Stainless Steel Rods for Internal Fixation of Femoral Transverse Fractures in Rabbits (Review Study)\",\"authors\":\"H. H. Nazht\",\"doi\":\"10.23880/OAJVSR-16000198\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The present study designed to focus on the advantages and disadvantages of using food grate stainless steel rods (FGSR) as internal fixation methods for induced transverse fractures in the mid shift of the femoral bones in rabbits.200 cases were collected from 2007 to 2020, all these cases were employed to induced transverse fractures in the mid shift of femoral bone, 100 of them used the rods for internal fixation, 80 of the cases used the rods for fixation the natural xenbony implantation from sheep or calves, and the others 20 cases used the rods for internal fixation of the synthetics nano bony implantation .The physical, chemical, clinical and radiographic parameters were used for evaluation, the physical and chemical analysis showed that the rods not change during sterilization, implantation or when exposed to different types of ray besides the chemical constant is about the same level measurement of the medical intramedullary pins (IMP), while the clinical observation revealed that the rods can used strongly and successfully for fracture fixation and support the animal to bear the weight, the limb used for walking gradually after 24-48 hours p. o. with some cases shown the FGSR pulled from the bone, other suffer from infection with pus formation with lateral deviation of the stifle joint or re-fracture. While the radiological finding revealed that the FGSR insert and fix the fractures fragment and the bony implantation, the pins seemed stable and fit the intramedullary canal and fracture fragments, while some cases shows that the pin not insert properly inside the femoral bone with case of multible and comminuted fractures, other case shown the FGSR pass and penetrate the stifle joint. The conclusion is, there are many advantages with minor or very little disadvantages for using the FGSR as internal fixation of the induced transverse fractures in the mid shift of the femoral bones and for natural and synthetics bony implantation in rabbits.\",\"PeriodicalId\":19494,\"journal\":{\"name\":\"Open Access Journal\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Open Access Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.23880/OAJVSR-16000198\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Open Access Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23880/OAJVSR-16000198","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本研究旨在探讨食物栅不锈钢棒(FGSR)作为兔股骨中移位性横向骨折内固定方法的优缺点。收集2007年至2020年的200例病例,所有病例均采用股骨中段诱导横向骨折,其中100例采用棒内固定,80例采用棒内固定羊或小牛的天然异种骨植入物,其余20例采用棒内固定合成纳米骨植入物。理化分析表明,该棒在灭菌、植入和不同类型射线照射过程中均无变化,其化学常数与医用髓内钉(IMP)的测量值相当,临床观察表明,该棒可牢固、成功地用于骨折固定和支撑动物负重。肢体在24-48小时后可逐渐行走,部分病例显示FGSR从骨中拔出,其他病例出现脓液形成感染并伴有膝关节外侧偏曲或再次骨折。虽然影像学检查显示FGSR插入并固定骨折碎片和骨植入物,钉看起来稳定,与髓内管和骨折碎片贴合,但在多发粉碎性骨折的病例中,有些病例显示钉不能正确插入股骨内,另一些病例显示FGSR穿过并穿透膝关节。综上所述,FGSR用于兔股骨中移位诱发的横向骨折内固定以及天然和人工骨植入有许多优点,缺点很小或很少。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Advantages and Disadvantages of using Food Grate Stainless Steel Rods for Internal Fixation of Femoral Transverse Fractures in Rabbits (Review Study)
The present study designed to focus on the advantages and disadvantages of using food grate stainless steel rods (FGSR) as internal fixation methods for induced transverse fractures in the mid shift of the femoral bones in rabbits.200 cases were collected from 2007 to 2020, all these cases were employed to induced transverse fractures in the mid shift of femoral bone, 100 of them used the rods for internal fixation, 80 of the cases used the rods for fixation the natural xenbony implantation from sheep or calves, and the others 20 cases used the rods for internal fixation of the synthetics nano bony implantation .The physical, chemical, clinical and radiographic parameters were used for evaluation, the physical and chemical analysis showed that the rods not change during sterilization, implantation or when exposed to different types of ray besides the chemical constant is about the same level measurement of the medical intramedullary pins (IMP), while the clinical observation revealed that the rods can used strongly and successfully for fracture fixation and support the animal to bear the weight, the limb used for walking gradually after 24-48 hours p. o. with some cases shown the FGSR pulled from the bone, other suffer from infection with pus formation with lateral deviation of the stifle joint or re-fracture. While the radiological finding revealed that the FGSR insert and fix the fractures fragment and the bony implantation, the pins seemed stable and fit the intramedullary canal and fracture fragments, while some cases shows that the pin not insert properly inside the femoral bone with case of multible and comminuted fractures, other case shown the FGSR pass and penetrate the stifle joint. The conclusion is, there are many advantages with minor or very little disadvantages for using the FGSR as internal fixation of the induced transverse fractures in the mid shift of the femoral bones and for natural and synthetics bony implantation in rabbits.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信