{"title":"基于ad5933的阻抗计原型的开发,用于阻抗传感器应用","authors":"Mohd Akmal Mhd Yusoff","doi":"10.1016/j.proche.2016.07.009","DOIUrl":null,"url":null,"abstract":"<div><p>This paper summarizes the progress done on the development of an impedance meter prototype. The prototype is to be a substitute for commercial equipment in reading impedimetric sensor for future portable applications. The prototype allows the impedimetric sensor to be excited with a frequency from 0.1-20kHz. Autolab's “Dummy Cell 2” has been used as the Device under Test (DUT). The DUT's phase response to AD5933 Evaluation Board and Hioki IM3590 Chemical Impedance analyzer in the range of 0.1-20kHz has been recorded and analyzed. It was found that the R-squared values of the regression lines were above 0.9 which indicates that AD5933 measurement is comparable to commercial equipment and suitable for impedimetric sensor application.</p></div>","PeriodicalId":20431,"journal":{"name":"Procedia Chemistry","volume":"20 ","pages":"Pages 56-59"},"PeriodicalIF":0.0000,"publicationDate":"2016-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.proche.2016.07.009","citationCount":"2","resultStr":"{\"title\":\"Development of an AD5933-based Impedance Meter Prototype for Impedimetric Sensor Applications\",\"authors\":\"Mohd Akmal Mhd Yusoff\",\"doi\":\"10.1016/j.proche.2016.07.009\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>This paper summarizes the progress done on the development of an impedance meter prototype. The prototype is to be a substitute for commercial equipment in reading impedimetric sensor for future portable applications. The prototype allows the impedimetric sensor to be excited with a frequency from 0.1-20kHz. Autolab's “Dummy Cell 2” has been used as the Device under Test (DUT). The DUT's phase response to AD5933 Evaluation Board and Hioki IM3590 Chemical Impedance analyzer in the range of 0.1-20kHz has been recorded and analyzed. It was found that the R-squared values of the regression lines were above 0.9 which indicates that AD5933 measurement is comparable to commercial equipment and suitable for impedimetric sensor application.</p></div>\",\"PeriodicalId\":20431,\"journal\":{\"name\":\"Procedia Chemistry\",\"volume\":\"20 \",\"pages\":\"Pages 56-59\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/j.proche.2016.07.009\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Procedia Chemistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1876619616300171\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Procedia Chemistry","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1876619616300171","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Development of an AD5933-based Impedance Meter Prototype for Impedimetric Sensor Applications
This paper summarizes the progress done on the development of an impedance meter prototype. The prototype is to be a substitute for commercial equipment in reading impedimetric sensor for future portable applications. The prototype allows the impedimetric sensor to be excited with a frequency from 0.1-20kHz. Autolab's “Dummy Cell 2” has been used as the Device under Test (DUT). The DUT's phase response to AD5933 Evaluation Board and Hioki IM3590 Chemical Impedance analyzer in the range of 0.1-20kHz has been recorded and analyzed. It was found that the R-squared values of the regression lines were above 0.9 which indicates that AD5933 measurement is comparable to commercial equipment and suitable for impedimetric sensor application.