单相DVC不同控制方法的研究

H. Hafezi, R. Faranda, C. Gandolfi, R. Chiumeo
{"title":"单相DVC不同控制方法的研究","authors":"H. Hafezi, R. Faranda, C. Gandolfi, R. Chiumeo","doi":"10.1109/ICHQP.2018.8378840","DOIUrl":null,"url":null,"abstract":"Power Quality (PQ) conditioning in LV distribution networks is an increasing concern within modern power system and Smart Grid systems. Several phenomena have classified in standard, among those, voltage sags and rms voltage drifts have been reported as most significant and frequent ones in both MV and LV distribution systems. Several solutions have been proposed to deal with these voltage disturbances. Dynamic Voltage Restorer (DVR) and Dynamic Voltage Conditioner (DVC) are the most promising solutions. Controlling these series connected devices is a challenge especially in single-phase schema which is an appreciated solution for Distribution System Operator (DSO). This paper investigates difference control strategies for single-phase DVC system. Control methods are explained in detail and MATLAB based simulation results are reported. Investigated control methods performance dealing with example voltage drop event have been reported.","PeriodicalId":6506,"journal":{"name":"2018 18th International Conference on Harmonics and Quality of Power (ICHQP)","volume":"1 1","pages":"1-6"},"PeriodicalIF":0.0000,"publicationDate":"2018-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Investigation on different control methods for single-phase DVC\",\"authors\":\"H. Hafezi, R. Faranda, C. Gandolfi, R. Chiumeo\",\"doi\":\"10.1109/ICHQP.2018.8378840\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Power Quality (PQ) conditioning in LV distribution networks is an increasing concern within modern power system and Smart Grid systems. Several phenomena have classified in standard, among those, voltage sags and rms voltage drifts have been reported as most significant and frequent ones in both MV and LV distribution systems. Several solutions have been proposed to deal with these voltage disturbances. Dynamic Voltage Restorer (DVR) and Dynamic Voltage Conditioner (DVC) are the most promising solutions. Controlling these series connected devices is a challenge especially in single-phase schema which is an appreciated solution for Distribution System Operator (DSO). This paper investigates difference control strategies for single-phase DVC system. Control methods are explained in detail and MATLAB based simulation results are reported. Investigated control methods performance dealing with example voltage drop event have been reported.\",\"PeriodicalId\":6506,\"journal\":{\"name\":\"2018 18th International Conference on Harmonics and Quality of Power (ICHQP)\",\"volume\":\"1 1\",\"pages\":\"1-6\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2018 18th International Conference on Harmonics and Quality of Power (ICHQP)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICHQP.2018.8378840\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2018 18th International Conference on Harmonics and Quality of Power (ICHQP)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHQP.2018.8378840","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

低压配电网的电能质量调节是现代电力系统和智能电网系统日益关注的问题。标准对几种现象进行了分类,其中电压跌落和均方根电压漂移是中低压配电系统中最重要和最常见的现象。已经提出了几种解决方案来处理这些电压干扰。动态电压恢复器(DVR)和动态电压调节器(DVC)是最有前途的解决方案。控制这些串联连接的设备是一项挑战,特别是在单相模式下,这是配电系统运营商(DSO)赞赏的解决方案。研究了单相DVC系统的差分控制策略。详细说明了控制方法,并给出了基于MATLAB的仿真结果。研究了处理实例电压降事件的控制方法的性能。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Investigation on different control methods for single-phase DVC
Power Quality (PQ) conditioning in LV distribution networks is an increasing concern within modern power system and Smart Grid systems. Several phenomena have classified in standard, among those, voltage sags and rms voltage drifts have been reported as most significant and frequent ones in both MV and LV distribution systems. Several solutions have been proposed to deal with these voltage disturbances. Dynamic Voltage Restorer (DVR) and Dynamic Voltage Conditioner (DVC) are the most promising solutions. Controlling these series connected devices is a challenge especially in single-phase schema which is an appreciated solution for Distribution System Operator (DSO). This paper investigates difference control strategies for single-phase DVC system. Control methods are explained in detail and MATLAB based simulation results are reported. Investigated control methods performance dealing with example voltage drop event have been reported.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信