94GHz无源毫米波成像系统在雾霾和烟雾条件下的目标检测

B. Luo, L. Ong, M. Karim
{"title":"94GHz无源毫米波成像系统在雾霾和烟雾条件下的目标检测","authors":"B. Luo, L. Ong, M. Karim","doi":"10.1109/IMWS-BIO.2013.6756216","DOIUrl":null,"url":null,"abstract":"A 94GHz passive millimeter wave (PMMW) imaging system is designed, prototyped and tested for target detection in haze and fog. To compact the system size and increase the scan area and speed, continue azimuth with step elevation (θ-φ) scanning is used here. Center frequency of the detected signal is 94GHz and the bandwidth is +/-2GHz. To increase the sensitivity and eliminate noise, an instrumentation amplifier and an active low pass filter with 10Hz cutoff bandwidth are adopted in this system. Test conducted in a sheath room shows that this system is suitable for detecting target in thick smoke.","PeriodicalId":6321,"journal":{"name":"2013 IEEE MTT-S International Microwave Workshop Series on RF and Wireless Technologies for Biomedical and Healthcare Applications (IMWS-BIO)","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2013-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Development of a 94GHz passive millimeter wave imaging system for target detection in haze and smoke\",\"authors\":\"B. Luo, L. Ong, M. Karim\",\"doi\":\"10.1109/IMWS-BIO.2013.6756216\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A 94GHz passive millimeter wave (PMMW) imaging system is designed, prototyped and tested for target detection in haze and fog. To compact the system size and increase the scan area and speed, continue azimuth with step elevation (θ-φ) scanning is used here. Center frequency of the detected signal is 94GHz and the bandwidth is +/-2GHz. To increase the sensitivity and eliminate noise, an instrumentation amplifier and an active low pass filter with 10Hz cutoff bandwidth are adopted in this system. Test conducted in a sheath room shows that this system is suitable for detecting target in thick smoke.\",\"PeriodicalId\":6321,\"journal\":{\"name\":\"2013 IEEE MTT-S International Microwave Workshop Series on RF and Wireless Technologies for Biomedical and Healthcare Applications (IMWS-BIO)\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2013 IEEE MTT-S International Microwave Workshop Series on RF and Wireless Technologies for Biomedical and Healthcare Applications (IMWS-BIO)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/IMWS-BIO.2013.6756216\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2013 IEEE MTT-S International Microwave Workshop Series on RF and Wireless Technologies for Biomedical and Healthcare Applications (IMWS-BIO)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IMWS-BIO.2013.6756216","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

设计了一种94GHz无源毫米波(PMMW)成像系统,用于雾霾条件下的目标检测。为了缩小系统尺寸,增加扫描面积和速度,这里采用步进仰角(θ-φ)连续方位角扫描。检测信号中心频率为94GHz,带宽为+/-2GHz。为了提高灵敏度和消除噪声,本系统采用了仪表放大器和截止带宽为10Hz的有源低通滤波器。在一个护套室进行的测试表明,该系统适用于浓烟中目标的探测。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Development of a 94GHz passive millimeter wave imaging system for target detection in haze and smoke
A 94GHz passive millimeter wave (PMMW) imaging system is designed, prototyped and tested for target detection in haze and fog. To compact the system size and increase the scan area and speed, continue azimuth with step elevation (θ-φ) scanning is used here. Center frequency of the detected signal is 94GHz and the bandwidth is +/-2GHz. To increase the sensitivity and eliminate noise, an instrumentation amplifier and an active low pass filter with 10Hz cutoff bandwidth are adopted in this system. Test conducted in a sheath room shows that this system is suitable for detecting target in thick smoke.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信