在两种不同的设置中,使用拟人Alderson-Rando幻体和tld胸腔评估TBI剂量异质性

Fernando Rodrigues, A. Nolasco, Luiz Cláudio Meira Belo, Claudete R E Silva, T. Fonseca
{"title":"在两种不同的设置中,使用拟人Alderson-Rando幻体和tld胸腔评估TBI剂量异质性","authors":"Fernando Rodrigues, A. Nolasco, Luiz Cláudio Meira Belo, Claudete R E Silva, T. Fonseca","doi":"10.15392/2319-0612.2023.2178","DOIUrl":null,"url":null,"abstract":"Total body irradiation (TBI) is a treatment modality of radiotherapy. It can be used for immunosuppression of transplanted patients or for metastatic protocols. In this study, TBI was performed using the anthropomorphic Alderson-Rando phantom filled with thermoluminescent dosimeters (TLDs) and irradiated with a 6 MV photon beam from the Elekta linear accelerator in two different setups, one at the hospital São Francisco, BH, MG and second at the hospital Santa Casa in Lavras, MG. The dose distribution in the left and right lungs was estimated, analyzed, and compared with results from the literature. Our results showed that dose homogeneity is more adequate with dual-field irradiation.\n ","PeriodicalId":9203,"journal":{"name":"Brazilian Journal of Radiation Sciences","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-06-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Assessment of dose heterogeneity in TBI using the thorax of the anthropomorphic Alderson-Rando phantom and TLDs in two different setups\",\"authors\":\"Fernando Rodrigues, A. Nolasco, Luiz Cláudio Meira Belo, Claudete R E Silva, T. Fonseca\",\"doi\":\"10.15392/2319-0612.2023.2178\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Total body irradiation (TBI) is a treatment modality of radiotherapy. It can be used for immunosuppression of transplanted patients or for metastatic protocols. In this study, TBI was performed using the anthropomorphic Alderson-Rando phantom filled with thermoluminescent dosimeters (TLDs) and irradiated with a 6 MV photon beam from the Elekta linear accelerator in two different setups, one at the hospital São Francisco, BH, MG and second at the hospital Santa Casa in Lavras, MG. The dose distribution in the left and right lungs was estimated, analyzed, and compared with results from the literature. Our results showed that dose homogeneity is more adequate with dual-field irradiation.\\n \",\"PeriodicalId\":9203,\"journal\":{\"name\":\"Brazilian Journal of Radiation Sciences\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-06-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Brazilian Journal of Radiation Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.15392/2319-0612.2023.2178\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Brazilian Journal of Radiation Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.15392/2319-0612.2023.2178","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

全身照射(TBI)是放射治疗的一种治疗方式。它可用于移植患者的免疫抑制或转移方案。在这项研究中,使用充满热致发光剂量计(tld)的拟人Alderson-Rando幻体进行TBI,并在两个不同的设置中使用Elekta线性加速器的6 MV光子束照射,一个在密歇根州 o Francisco医院,第二个在密歇根州拉夫拉斯的Santa Casa医院。估计、分析左、右肺的剂量分布,并与文献结果进行比较。结果表明,双场辐照的剂量均匀性较好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Assessment of dose heterogeneity in TBI using the thorax of the anthropomorphic Alderson-Rando phantom and TLDs in two different setups
Total body irradiation (TBI) is a treatment modality of radiotherapy. It can be used for immunosuppression of transplanted patients or for metastatic protocols. In this study, TBI was performed using the anthropomorphic Alderson-Rando phantom filled with thermoluminescent dosimeters (TLDs) and irradiated with a 6 MV photon beam from the Elekta linear accelerator in two different setups, one at the hospital São Francisco, BH, MG and second at the hospital Santa Casa in Lavras, MG. The dose distribution in the left and right lungs was estimated, analyzed, and compared with results from the literature. Our results showed that dose homogeneity is more adequate with dual-field irradiation.  
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信