{"title":"污染绝缘表面交流电弧放电的典型发射光谱研究","authors":"Shengwu Tan, Pengchao Wang, Junping Zhao, Hao Yang, R. Wen","doi":"10.1109/ICHVE49031.2020.9280066","DOIUrl":null,"url":null,"abstract":"Flashover of contaminated insulators is one of the major problems for the power distribution. Laboratory experiments have shown that the arc characteristics have great influences on the study of flashover performance of contaminated insulators. In order to investigate the characteristics of AC arc discharge on the polluted insulation surface, an experimental system was designed. The tests were carried out in the climate chamber. The optical emission spectroscopy was obtained by employing the fiber-optic spectrometer with shortest exposure time of 1 ms. The light emitted from the arc was coupled to the spectrometer by means of a focusing lens and a 3 m optical fiber. Typical optical emission spectrogram of different stages were obtained, and kinetics equation of different particles in the arc column was analyzed. And the spectrogram used for the prediction of critical flashover was proposed. It was shown that emission spectrum mainly includes sodium atom line and potassium atom line. With the increase of leakage current, the thickness of the continuous spectrum, spectral line intensity and the spectral composition increased. This work can enrich the investigation of partial arc parameters and may provide useful reference for the calculation of contamination flashover.","PeriodicalId":6763,"journal":{"name":"2020 IEEE International Conference on High Voltage Engineering and Application (ICHVE)","volume":"24 1","pages":"1-4"},"PeriodicalIF":0.0000,"publicationDate":"2020-09-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Study on the Typical Optical Emission Spectrograms of AC Arc Discharge over the Polluted Insulation Surface\",\"authors\":\"Shengwu Tan, Pengchao Wang, Junping Zhao, Hao Yang, R. Wen\",\"doi\":\"10.1109/ICHVE49031.2020.9280066\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Flashover of contaminated insulators is one of the major problems for the power distribution. Laboratory experiments have shown that the arc characteristics have great influences on the study of flashover performance of contaminated insulators. In order to investigate the characteristics of AC arc discharge on the polluted insulation surface, an experimental system was designed. The tests were carried out in the climate chamber. The optical emission spectroscopy was obtained by employing the fiber-optic spectrometer with shortest exposure time of 1 ms. The light emitted from the arc was coupled to the spectrometer by means of a focusing lens and a 3 m optical fiber. Typical optical emission spectrogram of different stages were obtained, and kinetics equation of different particles in the arc column was analyzed. And the spectrogram used for the prediction of critical flashover was proposed. It was shown that emission spectrum mainly includes sodium atom line and potassium atom line. With the increase of leakage current, the thickness of the continuous spectrum, spectral line intensity and the spectral composition increased. This work can enrich the investigation of partial arc parameters and may provide useful reference for the calculation of contamination flashover.\",\"PeriodicalId\":6763,\"journal\":{\"name\":\"2020 IEEE International Conference on High Voltage Engineering and Application (ICHVE)\",\"volume\":\"24 1\",\"pages\":\"1-4\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-09-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2020 IEEE International Conference on High Voltage Engineering and Application (ICHVE)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICHVE49031.2020.9280066\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2020 IEEE International Conference on High Voltage Engineering and Application (ICHVE)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICHVE49031.2020.9280066","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

污绝缘子的闪络是配电系统面临的主要问题之一。室内实验表明,电弧特性对污绝缘子闪络性能的研究有很大影响。为了研究污染绝缘表面的交流电弧放电特性,设计了一套实验系统。试验是在气候室进行的。利用曝光时间最短为1 ms的光纤光谱仪获得了发射光谱。电弧发出的光通过聚焦透镜和3米长的光纤耦合到光谱仪上。得到了不同阶段的典型发射光谱图,分析了不同颗粒在电弧柱中的动力学方程。并提出了用于临界闪络预测的谱图。结果表明,发射光谱主要包括钠原子线和钾原子线。随着泄漏电流的增大,连续谱的厚度、谱线强度和谱成分均增大。该工作丰富了局部电弧参数的研究,可为污染闪络的计算提供有益的参考。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Study on the Typical Optical Emission Spectrograms of AC Arc Discharge over the Polluted Insulation Surface
Flashover of contaminated insulators is one of the major problems for the power distribution. Laboratory experiments have shown that the arc characteristics have great influences on the study of flashover performance of contaminated insulators. In order to investigate the characteristics of AC arc discharge on the polluted insulation surface, an experimental system was designed. The tests were carried out in the climate chamber. The optical emission spectroscopy was obtained by employing the fiber-optic spectrometer with shortest exposure time of 1 ms. The light emitted from the arc was coupled to the spectrometer by means of a focusing lens and a 3 m optical fiber. Typical optical emission spectrogram of different stages were obtained, and kinetics equation of different particles in the arc column was analyzed. And the spectrogram used for the prediction of critical flashover was proposed. It was shown that emission spectrum mainly includes sodium atom line and potassium atom line. With the increase of leakage current, the thickness of the continuous spectrum, spectral line intensity and the spectral composition increased. This work can enrich the investigation of partial arc parameters and may provide useful reference for the calculation of contamination flashover.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信