温度和湿度对特高压直流输电线路可听噪声的影响

Wei Wang, Bing An, Chengrong Li, B. Luo, Xiaolin Li, Yixu Wang, Fei Fan, Boo-gen Yang
{"title":"温度和湿度对特高压直流输电线路可听噪声的影响","authors":"Wei Wang, Bing An, Chengrong Li, B. Luo, Xiaolin Li, Yixu Wang, Fei Fan, Boo-gen Yang","doi":"10.1109/CEIDP.2008.4772911","DOIUrl":null,"url":null,"abstract":"To research the effect of temperature and humidity on audible noise generated from UHV DC transmission lines, a mini corona cage has been constructed and put in a manual environment room, which temperature and humidity can be controlled. At the same time, an audible noise performance measuring system by using A/C weighted network audible noise meter and 8 kHz acoustic sensor have been set up too. The audible noise generated from a copper line have been measured in a mini corona cage not only at different humidity from 30% to 95% but also at different temperature from 0degC to 30degC. The relationship between audible noise level and temperature and humidity have been observed.","PeriodicalId":6381,"journal":{"name":"2008 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","volume":"1921 1","pages":"287-289"},"PeriodicalIF":0.0000,"publicationDate":"2008-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"The Effect of Temperature and Humidity on Audible Noise Generated from UHV DC Transmission Lines\",\"authors\":\"Wei Wang, Bing An, Chengrong Li, B. Luo, Xiaolin Li, Yixu Wang, Fei Fan, Boo-gen Yang\",\"doi\":\"10.1109/CEIDP.2008.4772911\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"To research the effect of temperature and humidity on audible noise generated from UHV DC transmission lines, a mini corona cage has been constructed and put in a manual environment room, which temperature and humidity can be controlled. At the same time, an audible noise performance measuring system by using A/C weighted network audible noise meter and 8 kHz acoustic sensor have been set up too. The audible noise generated from a copper line have been measured in a mini corona cage not only at different humidity from 30% to 95% but also at different temperature from 0degC to 30degC. The relationship between audible noise level and temperature and humidity have been observed.\",\"PeriodicalId\":6381,\"journal\":{\"name\":\"2008 Annual Report Conference on Electrical Insulation and Dielectric Phenomena\",\"volume\":\"1921 1\",\"pages\":\"287-289\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2008-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2008 Annual Report Conference on Electrical Insulation and Dielectric Phenomena\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CEIDP.2008.4772911\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2008 Annual Report Conference on Electrical Insulation and Dielectric Phenomena","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CEIDP.2008.4772911","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

摘要

为了研究温度和湿度对特高压直流输电线路可听噪声的影响,搭建了一个微型电晕笼,放置在一个温湿度可控的人工环境室内。同时,还建立了一套由空调加权网络声噪声计和8khz声传感器组成的声噪声性能测量系统。在微型电晕笼中测量了铜线在30% ~ 95%的不同湿度和0℃~ 30℃的不同温度下产生的可听噪声。已观察到可听噪声水平与温度和湿度之间的关系。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The Effect of Temperature and Humidity on Audible Noise Generated from UHV DC Transmission Lines
To research the effect of temperature and humidity on audible noise generated from UHV DC transmission lines, a mini corona cage has been constructed and put in a manual environment room, which temperature and humidity can be controlled. At the same time, an audible noise performance measuring system by using A/C weighted network audible noise meter and 8 kHz acoustic sensor have been set up too. The audible noise generated from a copper line have been measured in a mini corona cage not only at different humidity from 30% to 95% but also at different temperature from 0degC to 30degC. The relationship between audible noise level and temperature and humidity have been observed.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信