{"title":"考虑光伏发电系统防孤岛保护提高可靠性的保护装置布置","authors":"N. Jiravanstit, S. Chaitusaney","doi":"10.1109/ECTICON.2012.6254255","DOIUrl":null,"url":null,"abstract":"At present, the solar energy is a highly potential alternative for solving the energy crisis and improving system quality. On the other hand, the penetration of PVGS may cause an islanding problem. This paper derives Non Detection Zone (NDZ) of Over/Under voltage and Over/Under frequency method in order to increase accuracy for islanding prevention. In addition to safety issue, this paper proposes the protective device placement for system reliability improvement by using Genetic Algorithm (GA) optimization. The optimization also takes account of islanding prevention as constraint. The proposed method is brought to apply with Tasine 34-bus distribution system, and the simulation results are satisfactory.","PeriodicalId":6319,"journal":{"name":"2012 9th International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology","volume":"36 1","pages":"1-4"},"PeriodicalIF":0.0000,"publicationDate":"2012-05-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Protective device placement for reliability improvement by considering anti-islanding protection of PV generation system\",\"authors\":\"N. Jiravanstit, S. Chaitusaney\",\"doi\":\"10.1109/ECTICON.2012.6254255\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"At present, the solar energy is a highly potential alternative for solving the energy crisis and improving system quality. On the other hand, the penetration of PVGS may cause an islanding problem. This paper derives Non Detection Zone (NDZ) of Over/Under voltage and Over/Under frequency method in order to increase accuracy for islanding prevention. In addition to safety issue, this paper proposes the protective device placement for system reliability improvement by using Genetic Algorithm (GA) optimization. The optimization also takes account of islanding prevention as constraint. The proposed method is brought to apply with Tasine 34-bus distribution system, and the simulation results are satisfactory.\",\"PeriodicalId\":6319,\"journal\":{\"name\":\"2012 9th International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology\",\"volume\":\"36 1\",\"pages\":\"1-4\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-05-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2012 9th International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ECTICON.2012.6254255\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 9th International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ECTICON.2012.6254255","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Protective device placement for reliability improvement by considering anti-islanding protection of PV generation system
At present, the solar energy is a highly potential alternative for solving the energy crisis and improving system quality. On the other hand, the penetration of PVGS may cause an islanding problem. This paper derives Non Detection Zone (NDZ) of Over/Under voltage and Over/Under frequency method in order to increase accuracy for islanding prevention. In addition to safety issue, this paper proposes the protective device placement for system reliability improvement by using Genetic Algorithm (GA) optimization. The optimization also takes account of islanding prevention as constraint. The proposed method is brought to apply with Tasine 34-bus distribution system, and the simulation results are satisfactory.