M. Vijayakumari, D. Sundararajan
{"title":"用小波变换估计损坏波形的无功功率","authors":"M. Vijayakumari, D. Sundararajan","doi":"10.1109/ICCPCT.2015.7159284","DOIUrl":null,"url":null,"abstract":"In recent times, due to the increased use of the reactive power, it is important to bill the electrical power consumption based on both the active and reactive power components. Reactive power is a very significant factor in electric power systems since it affects the efficiency of these systems. For this reason, the measurement of reactive energy is also important. Several methods are used to measure reactive power. Reactive energy meters provide accurate measurement only if the input is fundamental, because meters are constructed for operating under sinusoidal conditions. Due to the widespread use of nonlinear loads and natural disturbances such as lightning, the power quality of the waveforms is considerably deteriorated. As the corrupted waveforms are composed of nonstationary components also, in order to estimate the true reactive power of the power system fundamental component, a time-frequency analysis is required. Therefore, in this paper, a DWT based algorithm is proposed to effectively estimate the reactive power component of the power system.","PeriodicalId":6650,"journal":{"name":"2015 International Conference on Circuits, Power and Computing Technologies [ICCPCT-2015]","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2015-03-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"Estimation of the reactive power of corrupted waveforms using the DWT\",\"authors\":\"M. Vijayakumari, D. Sundararajan\",\"doi\":\"10.1109/ICCPCT.2015.7159284\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In recent times, due to the increased use of the reactive power, it is important to bill the electrical power consumption based on both the active and reactive power components. Reactive power is a very significant factor in electric power systems since it affects the efficiency of these systems. For this reason, the measurement of reactive energy is also important. Several methods are used to measure reactive power. Reactive energy meters provide accurate measurement only if the input is fundamental, because meters are constructed for operating under sinusoidal conditions. Due to the widespread use of nonlinear loads and natural disturbances such as lightning, the power quality of the waveforms is considerably deteriorated. As the corrupted waveforms are composed of nonstationary components also, in order to estimate the true reactive power of the power system fundamental component, a time-frequency analysis is required. Therefore, in this paper, a DWT based algorithm is proposed to effectively estimate the reactive power component of the power system.\",\"PeriodicalId\":6650,\"journal\":{\"name\":\"2015 International Conference on Circuits, Power and Computing Technologies [ICCPCT-2015]\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-03-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2015 International Conference on Circuits, Power and Computing Technologies [ICCPCT-2015]\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICCPCT.2015.7159284\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2015 International Conference on Circuits, Power and Computing Technologies [ICCPCT-2015]","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICCPCT.2015.7159284","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

近年来,由于无功功率的使用增加,根据有功功率和无功功率分量对电力消耗进行计费是很重要的。无功功率是电力系统中一个非常重要的因素,因为它影响着电力系统的效率。因此,无功能的测量也很重要。有几种测量无功功率的方法。无功电能表只有在输入是基波的情况下才能提供准确的测量,因为电能表是在正弦条件下运行的。由于非线性负载和雷电等自然干扰的广泛使用,波形的电能质量大大恶化。由于损坏波形也由非平稳分量组成,为了估计电力系统基本分量的真实无功功率,需要进行时频分析。为此,本文提出了一种基于小波变换的有效估计电力系统无功分量的算法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Estimation of the reactive power of corrupted waveforms using the DWT
In recent times, due to the increased use of the reactive power, it is important to bill the electrical power consumption based on both the active and reactive power components. Reactive power is a very significant factor in electric power systems since it affects the efficiency of these systems. For this reason, the measurement of reactive energy is also important. Several methods are used to measure reactive power. Reactive energy meters provide accurate measurement only if the input is fundamental, because meters are constructed for operating under sinusoidal conditions. Due to the widespread use of nonlinear loads and natural disturbances such as lightning, the power quality of the waveforms is considerably deteriorated. As the corrupted waveforms are composed of nonstationary components also, in order to estimate the true reactive power of the power system fundamental component, a time-frequency analysis is required. Therefore, in this paper, a DWT based algorithm is proposed to effectively estimate the reactive power component of the power system.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信