{"title":"等动测力计配置对偏心腘绳肌力量指标的影响:对测试和训练的意义。","authors":"Rebecca Brown, Matt Greig","doi":"10.1080/15438627.2022.2079988","DOIUrl":null,"url":null,"abstract":"<p><p>Isokinetic dynamometry is the clinical gold standard for strength assessment but testing protocols and outcome metrics can lack functional relevance. To quantify the influence of dynamometer configuration on eccentric hamstring strength metrics, 23 trained participants completed isokinetic eccentric knee flexor trials at 180°·s<sup>-1</sup> in a seated and extended hip position. The extended position elicited a greater peak torque (P = 0.04) which was achieved at a significantly (P < 0.001) greater degree of knee flexion. Isokinetic range and functional range (defined as 85% of peak torque) were consistent at ~44° and ~21°, respectively, across trials, but were achieved with a more flexed knee in the extended hip configuration. Therefore, whilst the extended hip configuration might better reflect the biarticular nature of the hamstring musculature and the mechanism of hamstring strain injury, the sensitivity of strength metrics to configuration has implications for clinical assessment and training adaptations.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"The influence of isokinetic dynamometer configuration on eccentric hamstring strength metrics: implications for testing and training.\",\"authors\":\"Rebecca Brown, Matt Greig\",\"doi\":\"10.1080/15438627.2022.2079988\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Isokinetic dynamometry is the clinical gold standard for strength assessment but testing protocols and outcome metrics can lack functional relevance. To quantify the influence of dynamometer configuration on eccentric hamstring strength metrics, 23 trained participants completed isokinetic eccentric knee flexor trials at 180°·s<sup>-1</sup> in a seated and extended hip position. The extended position elicited a greater peak torque (P = 0.04) which was achieved at a significantly (P < 0.001) greater degree of knee flexion. Isokinetic range and functional range (defined as 85% of peak torque) were consistent at ~44° and ~21°, respectively, across trials, but were achieved with a more flexed knee in the extended hip configuration. Therefore, whilst the extended hip configuration might better reflect the biarticular nature of the hamstring musculature and the mechanism of hamstring strain injury, the sensitivity of strength metrics to configuration has implications for clinical assessment and training adaptations.</p>\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1080/15438627.2022.2079988\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2022/5/31 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/15438627.2022.2079988","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/5/31 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
The influence of isokinetic dynamometer configuration on eccentric hamstring strength metrics: implications for testing and training.
Isokinetic dynamometry is the clinical gold standard for strength assessment but testing protocols and outcome metrics can lack functional relevance. To quantify the influence of dynamometer configuration on eccentric hamstring strength metrics, 23 trained participants completed isokinetic eccentric knee flexor trials at 180°·s-1 in a seated and extended hip position. The extended position elicited a greater peak torque (P = 0.04) which was achieved at a significantly (P < 0.001) greater degree of knee flexion. Isokinetic range and functional range (defined as 85% of peak torque) were consistent at ~44° and ~21°, respectively, across trials, but were achieved with a more flexed knee in the extended hip configuration. Therefore, whilst the extended hip configuration might better reflect the biarticular nature of the hamstring musculature and the mechanism of hamstring strain injury, the sensitivity of strength metrics to configuration has implications for clinical assessment and training adaptations.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.