{"title":"离子液体与聚乙二醇形成双水相体系萃取铁、锰离子的机理","authors":"P. D. Ola, M. Matsumoto","doi":"10.15255/cabeq.2019.1621","DOIUrl":null,"url":null,"abstract":"In this work, we employed an aqueous two-phase system formed by an ionic liquid and polyethylene glycol for the separation of Fe(III), which is the most commonly used metal in the world, and Mn(II), which is currently used in many industries. We found that the extraction mechanisms of Fe(III) and Mn(II) were strongly influenced by the concentration of the hydrochloric acid that dissolved the metal salt. The ion pair reaction was the predominant mechanism that generated the Fe(III) and Mn(II) extractions. At a lower concentration of hydrochloric acid, metal ions were extracted because of the reaction between a metal cation and a dodecylsulfonate anion. At a higher concentration of hydrochloric acid, the reaction between a metal chlorocomplex anion and a hexylmethylimidazolium cation also proceeded. The aqueous two-phase system, composed of ionic liquid and polyethylene glycol, is promising for metal separation based on the difference in the affinity of metal with alkyl-sulfonate in a low HCl concentration and in the stability constant of metal chlorocomplex in a high HCl concentration. The maximum extractability of Fe(III) and Mn(III) was 57.8 and 75.3 %, respectively, with 0.3 mol dm–3 hydrochloric acid concentration.","PeriodicalId":9765,"journal":{"name":"Chemical and Biochemical Engineering Quarterly","volume":"24 1","pages":""},"PeriodicalIF":1.6000,"publicationDate":"2019-07-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Extraction Mechanism of Ferric and Manganese Ions with Aqueous Two-phase System Formed by Ionic Liquid and Polyethylene Glycol\",\"authors\":\"P. D. Ola, M. Matsumoto\",\"doi\":\"10.15255/cabeq.2019.1621\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this work, we employed an aqueous two-phase system formed by an ionic liquid and polyethylene glycol for the separation of Fe(III), which is the most commonly used metal in the world, and Mn(II), which is currently used in many industries. We found that the extraction mechanisms of Fe(III) and Mn(II) were strongly influenced by the concentration of the hydrochloric acid that dissolved the metal salt. The ion pair reaction was the predominant mechanism that generated the Fe(III) and Mn(II) extractions. At a lower concentration of hydrochloric acid, metal ions were extracted because of the reaction between a metal cation and a dodecylsulfonate anion. At a higher concentration of hydrochloric acid, the reaction between a metal chlorocomplex anion and a hexylmethylimidazolium cation also proceeded. The aqueous two-phase system, composed of ionic liquid and polyethylene glycol, is promising for metal separation based on the difference in the affinity of metal with alkyl-sulfonate in a low HCl concentration and in the stability constant of metal chlorocomplex in a high HCl concentration. The maximum extractability of Fe(III) and Mn(III) was 57.8 and 75.3 %, respectively, with 0.3 mol dm–3 hydrochloric acid concentration.\",\"PeriodicalId\":9765,\"journal\":{\"name\":\"Chemical and Biochemical Engineering Quarterly\",\"volume\":\"24 1\",\"pages\":\"\"},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2019-07-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Chemical and Biochemical Engineering Quarterly\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.15255/cabeq.2019.1621\",\"RegionNum\":4,\"RegionCategory\":\"生物学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"BIOTECHNOLOGY & APPLIED MICROBIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chemical and Biochemical Engineering Quarterly","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.15255/cabeq.2019.1621","RegionNum":4,"RegionCategory":"生物学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOTECHNOLOGY & APPLIED MICROBIOLOGY","Score":null,"Total":0}
Extraction Mechanism of Ferric and Manganese Ions with Aqueous Two-phase System Formed by Ionic Liquid and Polyethylene Glycol
In this work, we employed an aqueous two-phase system formed by an ionic liquid and polyethylene glycol for the separation of Fe(III), which is the most commonly used metal in the world, and Mn(II), which is currently used in many industries. We found that the extraction mechanisms of Fe(III) and Mn(II) were strongly influenced by the concentration of the hydrochloric acid that dissolved the metal salt. The ion pair reaction was the predominant mechanism that generated the Fe(III) and Mn(II) extractions. At a lower concentration of hydrochloric acid, metal ions were extracted because of the reaction between a metal cation and a dodecylsulfonate anion. At a higher concentration of hydrochloric acid, the reaction between a metal chlorocomplex anion and a hexylmethylimidazolium cation also proceeded. The aqueous two-phase system, composed of ionic liquid and polyethylene glycol, is promising for metal separation based on the difference in the affinity of metal with alkyl-sulfonate in a low HCl concentration and in the stability constant of metal chlorocomplex in a high HCl concentration. The maximum extractability of Fe(III) and Mn(III) was 57.8 and 75.3 %, respectively, with 0.3 mol dm–3 hydrochloric acid concentration.
期刊介绍:
The journal provides an international forum for presentation of original papers, reviews and discussions on the latest developments in chemical and biochemical engineering. The scope of the journal is wide and no limitation except relevance to chemical and biochemical engineering is required.
The criteria for the acceptance of papers are originality, quality of work and clarity of style. All papers are subject to reviewing by at least two international experts (blind peer review).
The language of the journal is English. Final versions of the manuscripts are subject to metric (SI units and IUPAC recommendations) and English language reviewing.
Editor and Editorial board make the final decision about acceptance of a manuscript.
Page charges are excluded.