经皮内镜胃造口管置换术

Shou-jiang Tang
{"title":"经皮内镜胃造口管置换术","authors":"Shou-jiang Tang","doi":"10.1016/j.vjgien.2014.01.002","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>Enteral feeding should be considered for patients with an intact and functional gastrointestinal tract. Percutaneous endoscopic gastrostomy (PEG) tube placement is indicated in patients requiring medium to long term enteral feeding (&gt;30 days) and with impaired swallowing. Previously placed PEG tube can dislodge or be inadvertently removed, blocked, or damaged. Gastrostomy tube replacement is not infrequently performed.</p></div><div><h3>Patients and methods</h3><p>In this video manuscript, the author demonstrates step-by-step PEG tube replacement in several clinical scenarios: standard gastrostomy feeding tube (with internal retention balloon or with internal collapsible bumper) removal and replacement; low-profile feeding tube replacement; and feeding tube replacement over a wire guide.</p></div><div><h3>Conclusions</h3><p>PEG tube replacement can be easily replaced at bed-side in most cases. Occasionally, in difficult cases gastrostomy feeding tube replacement needs endoscopic guidance and assistance.</p></div>","PeriodicalId":101274,"journal":{"name":"Video Journal and Encyclopedia of GI Endoscopy","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2014-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.vjgien.2014.01.002","citationCount":"0","resultStr":"{\"title\":\"Percutaneous Endoscopic Gastrostomy Tube Replacement\",\"authors\":\"Shou-jiang Tang\",\"doi\":\"10.1016/j.vjgien.2014.01.002\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><p>Enteral feeding should be considered for patients with an intact and functional gastrointestinal tract. Percutaneous endoscopic gastrostomy (PEG) tube placement is indicated in patients requiring medium to long term enteral feeding (&gt;30 days) and with impaired swallowing. Previously placed PEG tube can dislodge or be inadvertently removed, blocked, or damaged. Gastrostomy tube replacement is not infrequently performed.</p></div><div><h3>Patients and methods</h3><p>In this video manuscript, the author demonstrates step-by-step PEG tube replacement in several clinical scenarios: standard gastrostomy feeding tube (with internal retention balloon or with internal collapsible bumper) removal and replacement; low-profile feeding tube replacement; and feeding tube replacement over a wire guide.</p></div><div><h3>Conclusions</h3><p>PEG tube replacement can be easily replaced at bed-side in most cases. Occasionally, in difficult cases gastrostomy feeding tube replacement needs endoscopic guidance and assistance.</p></div>\",\"PeriodicalId\":101274,\"journal\":{\"name\":\"Video Journal and Encyclopedia of GI Endoscopy\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/j.vjgien.2014.01.002\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Video Journal and Encyclopedia of GI Endoscopy\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2212097114000338\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Video Journal and Encyclopedia of GI Endoscopy","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2212097114000338","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

背景:对于胃肠道功能完好的患者,应考虑肠内喂养。经皮内镜胃造口术(PEG)插管适用于需要中长期肠内喂养(30天)和吞咽障碍的患者。先前放置的PEG管可能会移位或被无意中移除,阻塞或损坏。胃造口管置换并不罕见。患者和方法在这篇视频手稿中,作者演示了在几种临床情况下逐步更换PEG管:标准胃造口喂养管(带有内部保留球囊或内部可折叠缓冲器)的取出和更换;低档进料管更换;用导丝器替换饲管。结论绝大多数病例均可方便地在床边更换speg管。偶尔,在困难的情况下,胃造口喂养管更换需要内镜指导和协助。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Percutaneous Endoscopic Gastrostomy Tube Replacement

Background

Enteral feeding should be considered for patients with an intact and functional gastrointestinal tract. Percutaneous endoscopic gastrostomy (PEG) tube placement is indicated in patients requiring medium to long term enteral feeding (>30 days) and with impaired swallowing. Previously placed PEG tube can dislodge or be inadvertently removed, blocked, or damaged. Gastrostomy tube replacement is not infrequently performed.

Patients and methods

In this video manuscript, the author demonstrates step-by-step PEG tube replacement in several clinical scenarios: standard gastrostomy feeding tube (with internal retention balloon or with internal collapsible bumper) removal and replacement; low-profile feeding tube replacement; and feeding tube replacement over a wire guide.

Conclusions

PEG tube replacement can be easily replaced at bed-side in most cases. Occasionally, in difficult cases gastrostomy feeding tube replacement needs endoscopic guidance and assistance.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信