pCA-HA/聚l -赖氨酸复合物质粒DNA的定量分析

Chien-Lung Hsu, Cheng-Wei Chen, Bo Zheng, Jii Chen, Tianhui Zhou
{"title":"pCA-HA/聚l -赖氨酸复合物质粒DNA的定量分析","authors":"Chien-Lung Hsu, Cheng-Wei Chen, Bo Zheng, Jii Chen, Tianhui Zhou","doi":"10.7019/TPJ.200709.0133","DOIUrl":null,"url":null,"abstract":"This report describes the comparison of four pDNA quantitative methods including UV/Visible spectro-photometry, agarose gel electrophoresis, EtBr staining fluoro-photometry and HPLCSEC method. Finally, the HPLC-SEC method was used to evaluate the interaction of plasmid DNA (pCA-HA) and poly-L-lysine (PLL). In the pCA-HA concentrations ranged form 3.125 to 50 μg/mL, the standard curve of pCA-HA has good linearity, accuracy (CV%<3%) and precision (Error%<4%) by using UV/Visible spectro-photometry. But the sensitivity is not enough to evaluate less than 3 μg/mL of pDNA. The intensity of fluorescene emission of EtBr stained pCA-HA is not dose dependent by using EtBr staining fluoro-photometry. The agarose gel electrophoresis had a high sensitivity (ng/mL level), but the accuracy (CV%>15%) and precision (Error%>15%) were not good in the range of 0.048~0.760 μg/mL pCA-HA. The standard curve of pCA-HA had good linearity, accuracy (CV%<3%) and precision (Error%<5%) in the pCA-HA concentration ranges from 0.4 to 1.2 μg/mL by using the HPLC-SEC method. PLL, a positive charged peptide, was used to condense DNA and enhance the transfection of DNA in cell. We used the HPLC-SEC method to evaluate the interaction of pDNA and PLL. When the charge of pCA-HA and PLL were almost the same, the peak of pDNA disappeared from the HPLC chromatogram. It means that the charge ratio of pCA-HA/PLL is close to 1 in the complex.","PeriodicalId":22409,"journal":{"name":"The Chinese Pharmaceutical Journal","volume":"24 1","pages":"133-140"},"PeriodicalIF":0.0000,"publicationDate":"2007-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Quantification of Plasmid DNA in pCA-HA/poly-L-lysine Complex\",\"authors\":\"Chien-Lung Hsu, Cheng-Wei Chen, Bo Zheng, Jii Chen, Tianhui Zhou\",\"doi\":\"10.7019/TPJ.200709.0133\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This report describes the comparison of four pDNA quantitative methods including UV/Visible spectro-photometry, agarose gel electrophoresis, EtBr staining fluoro-photometry and HPLCSEC method. Finally, the HPLC-SEC method was used to evaluate the interaction of plasmid DNA (pCA-HA) and poly-L-lysine (PLL). In the pCA-HA concentrations ranged form 3.125 to 50 μg/mL, the standard curve of pCA-HA has good linearity, accuracy (CV%<3%) and precision (Error%<4%) by using UV/Visible spectro-photometry. But the sensitivity is not enough to evaluate less than 3 μg/mL of pDNA. The intensity of fluorescene emission of EtBr stained pCA-HA is not dose dependent by using EtBr staining fluoro-photometry. The agarose gel electrophoresis had a high sensitivity (ng/mL level), but the accuracy (CV%>15%) and precision (Error%>15%) were not good in the range of 0.048~0.760 μg/mL pCA-HA. The standard curve of pCA-HA had good linearity, accuracy (CV%<3%) and precision (Error%<5%) in the pCA-HA concentration ranges from 0.4 to 1.2 μg/mL by using the HPLC-SEC method. PLL, a positive charged peptide, was used to condense DNA and enhance the transfection of DNA in cell. We used the HPLC-SEC method to evaluate the interaction of pDNA and PLL. When the charge of pCA-HA and PLL were almost the same, the peak of pDNA disappeared from the HPLC chromatogram. It means that the charge ratio of pCA-HA/PLL is close to 1 in the complex.\",\"PeriodicalId\":22409,\"journal\":{\"name\":\"The Chinese Pharmaceutical Journal\",\"volume\":\"24 1\",\"pages\":\"133-140\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Chinese Pharmaceutical Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.7019/TPJ.200709.0133\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Chinese Pharmaceutical Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.7019/TPJ.200709.0133","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文介绍了紫外/可见分光光度法、琼脂糖凝胶电泳法、EtBr染色荧光光度法和hplc法四种pDNA定量方法的比较。最后,采用HPLC-SEC方法评价质粒DNA (pCA-HA)与聚l -赖氨酸(PLL)的相互作用。在浓度3.125 ~ 50 μg/mL范围内,紫外/可见分光光度法测定的pCA-HA标准曲线具有良好的线性、准确度(CV%<3%)和精密度(误差%<4%)。但对于小于3 μg/mL的pDNA,灵敏度不够。采用EtBr染色荧光光度法,发现EtBr染色的pCA-HA荧光发射强度与剂量无关。琼脂糖凝胶电泳在0.048~0.760 μg/mL范围内具有较高的灵敏度(ng/mL水平),但准确度(CV%>15%)和精密度(Error%>15%)较差。HPLC-SEC法在浓度为0.4 ~ 1.2 μg/mL范围内,pCA-HA标准曲线具有良好的线性、准确度(CV%<3%)和精密度(Error%<5%)。PLL是一种带正电荷的肽,用于浓缩DNA,增强细胞内DNA的转染。我们采用HPLC-SEC方法评价pDNA与PLL的相互作用。当pCA-HA和PLL的电荷几乎相同时,pDNA的峰从HPLC图谱上消失。这意味着配合物中pCA-HA/PLL的电荷比接近于1。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Quantification of Plasmid DNA in pCA-HA/poly-L-lysine Complex
This report describes the comparison of four pDNA quantitative methods including UV/Visible spectro-photometry, agarose gel electrophoresis, EtBr staining fluoro-photometry and HPLCSEC method. Finally, the HPLC-SEC method was used to evaluate the interaction of plasmid DNA (pCA-HA) and poly-L-lysine (PLL). In the pCA-HA concentrations ranged form 3.125 to 50 μg/mL, the standard curve of pCA-HA has good linearity, accuracy (CV%<3%) and precision (Error%<4%) by using UV/Visible spectro-photometry. But the sensitivity is not enough to evaluate less than 3 μg/mL of pDNA. The intensity of fluorescene emission of EtBr stained pCA-HA is not dose dependent by using EtBr staining fluoro-photometry. The agarose gel electrophoresis had a high sensitivity (ng/mL level), but the accuracy (CV%>15%) and precision (Error%>15%) were not good in the range of 0.048~0.760 μg/mL pCA-HA. The standard curve of pCA-HA had good linearity, accuracy (CV%<3%) and precision (Error%<5%) in the pCA-HA concentration ranges from 0.4 to 1.2 μg/mL by using the HPLC-SEC method. PLL, a positive charged peptide, was used to condense DNA and enhance the transfection of DNA in cell. We used the HPLC-SEC method to evaluate the interaction of pDNA and PLL. When the charge of pCA-HA and PLL were almost the same, the peak of pDNA disappeared from the HPLC chromatogram. It means that the charge ratio of pCA-HA/PLL is close to 1 in the complex.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信