在与蚀刻-漂洗粘合剂系统杂交之前,HEMA磷酸盐作为磷酸的替代品对牙本质处理的影响。

Tatiana Foscaldo, G. B. dos Santos, L. Miragaya, M. Garcia, V. Hass, E. M. da Silva
{"title":"在与蚀刻-漂洗粘合剂系统杂交之前,HEMA磷酸盐作为磷酸的替代品对牙本质处理的影响。","authors":"Tatiana Foscaldo, G. B. dos Santos, L. Miragaya, M. Garcia, V. Hass, E. M. da Silva","doi":"10.3290/j.jad.a36891","DOIUrl":null,"url":null,"abstract":"PURPOSE To evaluate the effect of dentin treatment using HEMA phosphate (HEMA-P) on the microtensile bond strength (μTBS) and nanoleakage of an etch-and-rinse adhesive system. MATERIALS AND METHODS The occlusal surfaces of human molars were wet ground until superficial dentin was exposed. The specimens were then assigned to two groups according to dentin treatment: PA: 37% H₃PO₄ for 15 s; or HP: HEMA-P for 15 s. Adper Single Bond 2 was applied to the treated dentin surfaces and resin composite buildups were incrementally constructed over them. After 24-h storage in artificial saliva at 37°C, the bonded teeth were cut into resin-dentin sticks with a cross-sectional area of 1 mm², which were submitted to μTBS testing immediately or after 3 months of storage in artificial saliva at 37°C. Nanoleakage was assessed using SEM/EDS, and the interaction between dentin and H₃PO₄ or HEMA-P was evaluated by combining micro-Raman and FT-IR spectroscopy. The data were analyzed using two-way ANOVA and Tukey's HSD post-hoc test (α = 0.05). RESULTS HP presented significantly higher μTBS than PA at both times (p < 0.05). Both treatments maintained μTBS stability after 3 months of artificial saliva storage (p > 0.005). At both times, PA presented higher nanoleakage than HP (p < 0.05). CONCLUSIONS Both dentin treatments maintained μTBS stability after 3 months of artificial saliva storage. The use of HEMA-P was associated with less nanoleakage than was traditional phosphoric-acid etching.","PeriodicalId":94234,"journal":{"name":"The journal of adhesive dentistry","volume":"17 1","pages":"425-434"},"PeriodicalIF":0.0000,"publicationDate":"2016-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"Effect of HEMA Phosphate as an Alternative to Phosphoric Acid for Dentin Treatment Prior to Hybridization with Etch-and-Rinse Adhesive Systems.\",\"authors\":\"Tatiana Foscaldo, G. B. dos Santos, L. Miragaya, M. Garcia, V. Hass, E. M. da Silva\",\"doi\":\"10.3290/j.jad.a36891\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"PURPOSE To evaluate the effect of dentin treatment using HEMA phosphate (HEMA-P) on the microtensile bond strength (μTBS) and nanoleakage of an etch-and-rinse adhesive system. MATERIALS AND METHODS The occlusal surfaces of human molars were wet ground until superficial dentin was exposed. The specimens were then assigned to two groups according to dentin treatment: PA: 37% H₃PO₄ for 15 s; or HP: HEMA-P for 15 s. Adper Single Bond 2 was applied to the treated dentin surfaces and resin composite buildups were incrementally constructed over them. After 24-h storage in artificial saliva at 37°C, the bonded teeth were cut into resin-dentin sticks with a cross-sectional area of 1 mm², which were submitted to μTBS testing immediately or after 3 months of storage in artificial saliva at 37°C. Nanoleakage was assessed using SEM/EDS, and the interaction between dentin and H₃PO₄ or HEMA-P was evaluated by combining micro-Raman and FT-IR spectroscopy. The data were analyzed using two-way ANOVA and Tukey's HSD post-hoc test (α = 0.05). RESULTS HP presented significantly higher μTBS than PA at both times (p < 0.05). Both treatments maintained μTBS stability after 3 months of artificial saliva storage (p > 0.005). At both times, PA presented higher nanoleakage than HP (p < 0.05). CONCLUSIONS Both dentin treatments maintained μTBS stability after 3 months of artificial saliva storage. The use of HEMA-P was associated with less nanoleakage than was traditional phosphoric-acid etching.\",\"PeriodicalId\":94234,\"journal\":{\"name\":\"The journal of adhesive dentistry\",\"volume\":\"17 1\",\"pages\":\"425-434\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The journal of adhesive dentistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3290/j.jad.a36891\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The journal of adhesive dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3290/j.jad.a36891","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

目的评价磷酸HEMA (HEMA- p)处理牙本质对蚀刻-冲洗胶粘剂体系微拉伸结合强度(μTBS)和纳米渗漏的影响。材料与方法将磨牙咬合面湿磨至暴露浅牙本质。然后根据牙本质的处理将标本分为两组:PA: 37% H₃PO₄15 s;HP: HEMA-P,持续15秒。将Adper单键2应用于处理过的牙本质表面,并在其上逐渐构建树脂复合材料。37℃人工唾液中保存24 h后,将粘接牙切成截面积为1 mm²的树脂-牙质棒,立即或在37℃人工唾液中保存3个月后进行μTBS测试。采用SEM/EDS分析了牙本质与H₃PO₄或HEMA-P的相互作用,并用微拉曼光谱和FT-IR光谱分析了牙本质与H₃PO₄或HEMA-P的相互作用。采用双因素方差分析和Tukey’s HSD事后检验(α = 0.05)。结果shp的μTBS均显著高于PA (p < 0.05)。人工唾液储存3个月后,两组患者的μTBS均保持稳定(p > 0.005)。两种情况下,PA的纳米泄漏量均高于HP (p < 0.05)。结论人工唾液保存3个月后,两种牙本质处理均保持μTBS稳定。与传统的磷酸刻蚀相比,HEMA-P的使用与更少的纳米泄漏有关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Effect of HEMA Phosphate as an Alternative to Phosphoric Acid for Dentin Treatment Prior to Hybridization with Etch-and-Rinse Adhesive Systems.
PURPOSE To evaluate the effect of dentin treatment using HEMA phosphate (HEMA-P) on the microtensile bond strength (μTBS) and nanoleakage of an etch-and-rinse adhesive system. MATERIALS AND METHODS The occlusal surfaces of human molars were wet ground until superficial dentin was exposed. The specimens were then assigned to two groups according to dentin treatment: PA: 37% H₃PO₄ for 15 s; or HP: HEMA-P for 15 s. Adper Single Bond 2 was applied to the treated dentin surfaces and resin composite buildups were incrementally constructed over them. After 24-h storage in artificial saliva at 37°C, the bonded teeth were cut into resin-dentin sticks with a cross-sectional area of 1 mm², which were submitted to μTBS testing immediately or after 3 months of storage in artificial saliva at 37°C. Nanoleakage was assessed using SEM/EDS, and the interaction between dentin and H₃PO₄ or HEMA-P was evaluated by combining micro-Raman and FT-IR spectroscopy. The data were analyzed using two-way ANOVA and Tukey's HSD post-hoc test (α = 0.05). RESULTS HP presented significantly higher μTBS than PA at both times (p < 0.05). Both treatments maintained μTBS stability after 3 months of artificial saliva storage (p > 0.005). At both times, PA presented higher nanoleakage than HP (p < 0.05). CONCLUSIONS Both dentin treatments maintained μTBS stability after 3 months of artificial saliva storage. The use of HEMA-P was associated with less nanoleakage than was traditional phosphoric-acid etching.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信