尼日利亚东北部某州诊断x射线室设计和铅围裙屏蔽完整性调查

A. Mohammed, C. Nzotta, B. F. Nkubli, A. Umar, S. Y. Bappah, P. E. Osayaba, A. A. Dukku
{"title":"尼日利亚东北部某州诊断x射线室设计和铅围裙屏蔽完整性调查","authors":"A. Mohammed, C. Nzotta, B. F. Nkubli, A. Umar, S. Y. Bappah, P. E. Osayaba, A. A. Dukku","doi":"10.48153/jrrs/2020/teza1728","DOIUrl":null,"url":null,"abstract":"Background: X-ray facility design and shielding integrity is meant to optimize radiation safety of patients, staff and the general public. \n\nObjectives: To determine the conformity to x-ray room design standards and the functional efficacy of lead aprons in the surveyed facilities.\n\nMaterials and Method: The survey was conducted in six radio diagnostic centres in Gombe State Nigeria, labelled A to F for anonymity. The building layout of the radiology departments was sketched to show the dimensions (L x B x H) and adjoining structures. Datasheets were also used to record information about the radio-diagnostic facility. Lead aprons were inspected for defects by physical observation and by x-ray exposure.\n\nResults: The x-ray room dimension of the six radio diagnostic centres with A (24 m2), B (14.8 m2), C (30 m2), D (36 m2), E (21.2 m2) and F (25 m2). All the walls of\n\nthe radio-diagnostic room of facility A, B, C and D were lined with 2 mm lead equivalent, whereas E and F were not. About 7 (38.8%) of lead aprons inspected were defective, while 11 (61.1%) were not defective.\n\nConclusion: There are compromises noted in the design of facility B and the majority of the lead aprons inspected showed good functional efficacy.","PeriodicalId":16919,"journal":{"name":"Journal of Radiography and Radiation Sciences","volume":"107 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2020-11-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"\\\"A Survey of Diagnostic X-ray room design and shielding Integrity of Lead\\nAprons in a State in North-Eastern Nigeria.\\\"\",\"authors\":\"A. Mohammed, C. Nzotta, B. F. Nkubli, A. Umar, S. Y. Bappah, P. E. Osayaba, A. A. Dukku\",\"doi\":\"10.48153/jrrs/2020/teza1728\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: X-ray facility design and shielding integrity is meant to optimize radiation safety of patients, staff and the general public. \\n\\nObjectives: To determine the conformity to x-ray room design standards and the functional efficacy of lead aprons in the surveyed facilities.\\n\\nMaterials and Method: The survey was conducted in six radio diagnostic centres in Gombe State Nigeria, labelled A to F for anonymity. The building layout of the radiology departments was sketched to show the dimensions (L x B x H) and adjoining structures. Datasheets were also used to record information about the radio-diagnostic facility. Lead aprons were inspected for defects by physical observation and by x-ray exposure.\\n\\nResults: The x-ray room dimension of the six radio diagnostic centres with A (24 m2), B (14.8 m2), C (30 m2), D (36 m2), E (21.2 m2) and F (25 m2). All the walls of\\n\\nthe radio-diagnostic room of facility A, B, C and D were lined with 2 mm lead equivalent, whereas E and F were not. About 7 (38.8%) of lead aprons inspected were defective, while 11 (61.1%) were not defective.\\n\\nConclusion: There are compromises noted in the design of facility B and the majority of the lead aprons inspected showed good functional efficacy.\",\"PeriodicalId\":16919,\"journal\":{\"name\":\"Journal of Radiography and Radiation Sciences\",\"volume\":\"107 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-11-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Radiography and Radiation Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.48153/jrrs/2020/teza1728\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Radiography and Radiation Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.48153/jrrs/2020/teza1728","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

背景:x射线设施的设计和屏蔽完整性旨在优化患者、工作人员和公众的辐射安全。目的:确定所调查设施中铅围裙是否符合x射线室设计标准及功能功效。材料和方法:该调查在尼日利亚贡贝州的六个无线电诊断中心进行,匿名标记为A至F。放射科的建筑布局草图显示了尺寸(长x宽x高)和邻近的结构。数据表也用于记录有关放射诊断设施的信息。通过物理观察和x射线曝光检查铅围裙是否有缺陷。结果:A (24 m2)、B (14.8 m2)、C (30 m2)、D (36 m2)、E (21.2 m2)、F (25 m2) 6个放射诊断中心的x线室尺寸。设备A、B、C、D的放射诊断室墙壁均铺有2 mm当量铅,而设备E、F则没有。经检验的铅围裙中,不良品7件(38.8%),无不良品11件(61.1%)。结论:B设施的设计存在一定的缺陷,经检查的铅围裙大部分功能效果良好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
"A Survey of Diagnostic X-ray room design and shielding Integrity of Lead Aprons in a State in North-Eastern Nigeria."
Background: X-ray facility design and shielding integrity is meant to optimize radiation safety of patients, staff and the general public. Objectives: To determine the conformity to x-ray room design standards and the functional efficacy of lead aprons in the surveyed facilities. Materials and Method: The survey was conducted in six radio diagnostic centres in Gombe State Nigeria, labelled A to F for anonymity. The building layout of the radiology departments was sketched to show the dimensions (L x B x H) and adjoining structures. Datasheets were also used to record information about the radio-diagnostic facility. Lead aprons were inspected for defects by physical observation and by x-ray exposure. Results: The x-ray room dimension of the six radio diagnostic centres with A (24 m2), B (14.8 m2), C (30 m2), D (36 m2), E (21.2 m2) and F (25 m2). All the walls of the radio-diagnostic room of facility A, B, C and D were lined with 2 mm lead equivalent, whereas E and F were not. About 7 (38.8%) of lead aprons inspected were defective, while 11 (61.1%) were not defective. Conclusion: There are compromises noted in the design of facility B and the majority of the lead aprons inspected showed good functional efficacy.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信