峰值速率浊度法测定脂蛋白溶血干扰的研究(a)

Fabrice Lefèvre, Philippe Gillery
{"title":"峰值速率浊度法测定脂蛋白溶血干扰的研究(a)","authors":"Fabrice Lefèvre,&nbsp;Philippe Gillery","doi":"10.1002/(SICI)1098-2728(2000)12:1<23::AID-LRA4>3.0.CO;2-8","DOIUrl":null,"url":null,"abstract":"<p>Lipoprotein(a) [Lp(a)] is considered an independent risk factor in atherosclerosis and thrombosis. Its measurement in clinical laboratories necessitates the use of reliable methods and a strict control of preanalytical conditions. We studied here the potential interference of hemolysis on a peak rate nephelometric method. Serum samples were spiked with up to 500 μmol/L hemoglobin (Hb), and Lp(a) was measured with a Beckman Array 360 analyzer. Hb supplementation induced a significant decrease of Lp(a) values: −15% and −25% (p &lt; 0.01) for Hb concentrations 200 and 500 μmol/L, respectively. Similar results were obtained when Hb addition was done before and after the manual step of sample predilution (1/5, v/v) in PEG-containing buffer. No significant difference of Hb interference was noticed according to apo(a) phenotypes. Our results indicate that hemolysis may significantly alter Lp(a) values obtained with this method, probably because of the low-dilution rate of samples. Even if this interference is of limited extent, it should be taken into account when interpretating results close to decisional values used for risk assessment. © 2000 John Wiley &amp; Sons, Inc. Lab Robotics and Automation 12:23–26, 2000</p>","PeriodicalId":100863,"journal":{"name":"Laboratory Robotics and Automation","volume":"12 1","pages":"23-26"},"PeriodicalIF":0.0000,"publicationDate":"2000-02-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/(SICI)1098-2728(2000)12:1<23::AID-LRA4>3.0.CO;2-8","citationCount":"0","resultStr":"{\"title\":\"Study of hemolysis interference with a peak rate nephelometric assay of lipoprotein(a)\",\"authors\":\"Fabrice Lefèvre,&nbsp;Philippe Gillery\",\"doi\":\"10.1002/(SICI)1098-2728(2000)12:1<23::AID-LRA4>3.0.CO;2-8\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Lipoprotein(a) [Lp(a)] is considered an independent risk factor in atherosclerosis and thrombosis. Its measurement in clinical laboratories necessitates the use of reliable methods and a strict control of preanalytical conditions. We studied here the potential interference of hemolysis on a peak rate nephelometric method. Serum samples were spiked with up to 500 μmol/L hemoglobin (Hb), and Lp(a) was measured with a Beckman Array 360 analyzer. Hb supplementation induced a significant decrease of Lp(a) values: −15% and −25% (p &lt; 0.01) for Hb concentrations 200 and 500 μmol/L, respectively. Similar results were obtained when Hb addition was done before and after the manual step of sample predilution (1/5, v/v) in PEG-containing buffer. No significant difference of Hb interference was noticed according to apo(a) phenotypes. Our results indicate that hemolysis may significantly alter Lp(a) values obtained with this method, probably because of the low-dilution rate of samples. Even if this interference is of limited extent, it should be taken into account when interpretating results close to decisional values used for risk assessment. © 2000 John Wiley &amp; Sons, Inc. Lab Robotics and Automation 12:23–26, 2000</p>\",\"PeriodicalId\":100863,\"journal\":{\"name\":\"Laboratory Robotics and Automation\",\"volume\":\"12 1\",\"pages\":\"23-26\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2000-02-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1002/(SICI)1098-2728(2000)12:1<23::AID-LRA4>3.0.CO;2-8\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Laboratory Robotics and Automation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/%28SICI%291098-2728%282000%2912%3A1%3C23%3A%3AAID-LRA4%3E3.0.CO%3B2-8\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Laboratory Robotics and Automation","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/%28SICI%291098-2728%282000%2912%3A1%3C23%3A%3AAID-LRA4%3E3.0.CO%3B2-8","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

脂蛋白(a) [Lp(a)]被认为是动脉粥样硬化和血栓形成的独立危险因素。在临床实验室中,它的测量需要使用可靠的方法和严格控制分析前条件。本文研究了溶血对峰速率浊度法的潜在干扰。血清样品加入高达500 μmol/L的血红蛋白(Hb),用Beckman Array 360分析仪测定Lp(a)。补充Hb导致Lp(a)值显著降低:- 15%和- 25% (p <Hb浓度分别为200和500 μmol/L, p < 0.01)。在含peg缓冲液中样品预稀释(1/5,v/v)的手动步骤之前和之后分别添加Hb,得到类似的结果。根据载脂蛋白(a)表型,Hb干扰无显著差异。我们的结果表明,溶血可能会显著改变用这种方法获得的Lp(a)值,可能是因为样品的稀释率低。即使这种干扰程度有限,在解释接近用于风险评估的决策值的结果时也应考虑到这种干扰。©2000 John Wiley &儿子,Inc。实验室机器人与自动化,2000
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Study of hemolysis interference with a peak rate nephelometric assay of lipoprotein(a)

Lipoprotein(a) [Lp(a)] is considered an independent risk factor in atherosclerosis and thrombosis. Its measurement in clinical laboratories necessitates the use of reliable methods and a strict control of preanalytical conditions. We studied here the potential interference of hemolysis on a peak rate nephelometric method. Serum samples were spiked with up to 500 μmol/L hemoglobin (Hb), and Lp(a) was measured with a Beckman Array 360 analyzer. Hb supplementation induced a significant decrease of Lp(a) values: −15% and −25% (p < 0.01) for Hb concentrations 200 and 500 μmol/L, respectively. Similar results were obtained when Hb addition was done before and after the manual step of sample predilution (1/5, v/v) in PEG-containing buffer. No significant difference of Hb interference was noticed according to apo(a) phenotypes. Our results indicate that hemolysis may significantly alter Lp(a) values obtained with this method, probably because of the low-dilution rate of samples. Even if this interference is of limited extent, it should be taken into account when interpretating results close to decisional values used for risk assessment. © 2000 John Wiley & Sons, Inc. Lab Robotics and Automation 12:23–26, 2000

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信