采用测量不透明度的阻抗流式细胞术测定颗粒大小

Douwe S de Bruijn, K. F. Jorissen, W. Olthuis, A. van den Berg
{"title":"采用测量不透明度的阻抗流式细胞术测定颗粒大小","authors":"Douwe S de Bruijn, K. F. Jorissen, W. Olthuis, A. van den Berg","doi":"10.1109/Transducers50396.2021.9495740","DOIUrl":null,"url":null,"abstract":"Microfluidic electrical flow cytometry is a popular method to study a wide variety of biological cell properties. Unfortunately, when using coplanar electrodes, this method is sensitive to positional differences of passing particles or cells. In this work we present a novel compensation method to account for the particle position in a coplanar electrode setup using the measured electrical opacity. We demonstrate an accurate size discrimination of 5, 6 and 7 µm polystyrene beads irrespective of their position using the measured electrical opacity making use of the variation of electrical field strength with height in the channel. Thus, only two electrodes are required, which is favorable for microfluidic devices with size limitations.","PeriodicalId":6814,"journal":{"name":"2021 21st International Conference on Solid-State Sensors, Actuators and Microsystems (Transducers)","volume":"1 1","pages":"1036-1039"},"PeriodicalIF":0.0000,"publicationDate":"2021-06-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Particle Size Determination in Impedance Flow Cytometry Using Measured Opacity\",\"authors\":\"Douwe S de Bruijn, K. F. Jorissen, W. Olthuis, A. van den Berg\",\"doi\":\"10.1109/Transducers50396.2021.9495740\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Microfluidic electrical flow cytometry is a popular method to study a wide variety of biological cell properties. Unfortunately, when using coplanar electrodes, this method is sensitive to positional differences of passing particles or cells. In this work we present a novel compensation method to account for the particle position in a coplanar electrode setup using the measured electrical opacity. We demonstrate an accurate size discrimination of 5, 6 and 7 µm polystyrene beads irrespective of their position using the measured electrical opacity making use of the variation of electrical field strength with height in the channel. Thus, only two electrodes are required, which is favorable for microfluidic devices with size limitations.\",\"PeriodicalId\":6814,\"journal\":{\"name\":\"2021 21st International Conference on Solid-State Sensors, Actuators and Microsystems (Transducers)\",\"volume\":\"1 1\",\"pages\":\"1036-1039\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-06-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2021 21st International Conference on Solid-State Sensors, Actuators and Microsystems (Transducers)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/Transducers50396.2021.9495740\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2021 21st International Conference on Solid-State Sensors, Actuators and Microsystems (Transducers)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/Transducers50396.2021.9495740","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

微流控电流式细胞术是研究多种生物细胞特性的常用方法。不幸的是,当使用共面电极时,这种方法对通过的粒子或细胞的位置差异很敏感。在这项工作中,我们提出了一种新的补偿方法,利用测量的电不透明度来解释共面电极设置中的粒子位置。我们利用电场强度随通道高度的变化,利用测量的电不透明度,证明了5,6和7 μ m聚苯乙烯珠的精确尺寸判别,而不管它们的位置如何。因此,只需要两个电极,这有利于具有尺寸限制的微流体装置。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Particle Size Determination in Impedance Flow Cytometry Using Measured Opacity
Microfluidic electrical flow cytometry is a popular method to study a wide variety of biological cell properties. Unfortunately, when using coplanar electrodes, this method is sensitive to positional differences of passing particles or cells. In this work we present a novel compensation method to account for the particle position in a coplanar electrode setup using the measured electrical opacity. We demonstrate an accurate size discrimination of 5, 6 and 7 µm polystyrene beads irrespective of their position using the measured electrical opacity making use of the variation of electrical field strength with height in the channel. Thus, only two electrodes are required, which is favorable for microfluidic devices with size limitations.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信