同步注射有效混合流分析(SIEMA):发展与应用

N. Ratanawimarnwong, N. Teshima, T. Sakai, D. Nacapricha, S. Motomizu
{"title":"同步注射有效混合流分析(SIEMA):发展与应用","authors":"N. Ratanawimarnwong, N. Teshima, T. Sakai, D. Nacapricha, S. Motomizu","doi":"10.24688/JFIA.31.1_15","DOIUrl":null,"url":null,"abstract":"The development and application of a new simultaneous injection- effective mixing flow analysis (SIEMA) is described. The manifold is based on one syringe pump with a two-way solenoid valve, a set of holding coils and three-way solenoid valves, two multiport connectors, a mixing coil and a detector. The system is compact and is controlled by a laptop computer. Some analytical features of SIEMA are compared with other flow-based systems in terms of mixing efficiency, reagent consumption and sample throughput. Applications of the SIEMA system are demonstrated for environmental and clinical analysis.","PeriodicalId":15808,"journal":{"name":"Journal of flow injection analysis","volume":"95 1","pages":"15-17"},"PeriodicalIF":0.0000,"publicationDate":"2014-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Simultaneous Injection Effective Mixing Flow Analysis (SIEMA): Its Development and Application\",\"authors\":\"N. Ratanawimarnwong, N. Teshima, T. Sakai, D. Nacapricha, S. Motomizu\",\"doi\":\"10.24688/JFIA.31.1_15\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The development and application of a new simultaneous injection- effective mixing flow analysis (SIEMA) is described. The manifold is based on one syringe pump with a two-way solenoid valve, a set of holding coils and three-way solenoid valves, two multiport connectors, a mixing coil and a detector. The system is compact and is controlled by a laptop computer. Some analytical features of SIEMA are compared with other flow-based systems in terms of mixing efficiency, reagent consumption and sample throughput. Applications of the SIEMA system are demonstrated for environmental and clinical analysis.\",\"PeriodicalId\":15808,\"journal\":{\"name\":\"Journal of flow injection analysis\",\"volume\":\"95 1\",\"pages\":\"15-17\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of flow injection analysis\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.24688/JFIA.31.1_15\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of flow injection analysis","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.24688/JFIA.31.1_15","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

介绍了一种新型的同步注射-有效混合流分析(SIEMA)的发展和应用。歧管是基于一个注射泵与一个双向电磁阀,一组保持线圈和三通电磁阀,两个多端口连接器,一个混合线圈和一个检测器。该系统结构紧凑,由一台笔记本电脑控制。在混合效率、试剂消耗和样品吞吐量方面,比较了SIEMA的一些分析特性。该系统在环境和临床分析中的应用得到了演示。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Simultaneous Injection Effective Mixing Flow Analysis (SIEMA): Its Development and Application
The development and application of a new simultaneous injection- effective mixing flow analysis (SIEMA) is described. The manifold is based on one syringe pump with a two-way solenoid valve, a set of holding coils and three-way solenoid valves, two multiport connectors, a mixing coil and a detector. The system is compact and is controlled by a laptop computer. Some analytical features of SIEMA are compared with other flow-based systems in terms of mixing efficiency, reagent consumption and sample throughput. Applications of the SIEMA system are demonstrated for environmental and clinical analysis.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信