地空激光时间传递中地面系统偏差的识别与标定

I. Procházka, J. Blažej, J. Kodet
{"title":"地空激光时间传递中地面系统偏差的识别与标定","authors":"I. Procházka, J. Blažej, J. Kodet","doi":"10.1109/FCS.2015.7138963","DOIUrl":null,"url":null,"abstract":"Laser time transfer is and attractive technique to transfer time ground to space with picosecond precision and systematic errors on the level of tens of picoseconds. Recently the European Laser Timing experiment is under construction in the frame of the European Space Agency mission Atomic Clock Ensemble in Space. The objective of this laser time transfer is synchronization of the ground based clocks and the clock on board the International Space Station with picosecond precision and the accuracy better than 50 picoseconds We are reporting on a progress in identification and calibration of the biases associated to both ground and space segment. To characterize the delays of a ground segment the Calibration Device has been developed and tested. It enables to calibrate the ground based laser systems for their systematic timing biases. As a result the ground to ground time transfer in an ELT experiment should be accomplished with systematic errors not higher than 25 picoseconds. To determine the delays of a space segment the new calibration procedure has been designed and tested as well. The calibration test results will be presented.","PeriodicalId":57667,"journal":{"name":"时间频率公报","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2015-04-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Identification and calibration of ground system biases in ground to space laser time transfer\",\"authors\":\"I. Procházka, J. Blažej, J. Kodet\",\"doi\":\"10.1109/FCS.2015.7138963\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Laser time transfer is and attractive technique to transfer time ground to space with picosecond precision and systematic errors on the level of tens of picoseconds. Recently the European Laser Timing experiment is under construction in the frame of the European Space Agency mission Atomic Clock Ensemble in Space. The objective of this laser time transfer is synchronization of the ground based clocks and the clock on board the International Space Station with picosecond precision and the accuracy better than 50 picoseconds We are reporting on a progress in identification and calibration of the biases associated to both ground and space segment. To characterize the delays of a ground segment the Calibration Device has been developed and tested. It enables to calibrate the ground based laser systems for their systematic timing biases. As a result the ground to ground time transfer in an ELT experiment should be accomplished with systematic errors not higher than 25 picoseconds. To determine the delays of a space segment the new calibration procedure has been designed and tested as well. The calibration test results will be presented.\",\"PeriodicalId\":57667,\"journal\":{\"name\":\"时间频率公报\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-04-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"时间频率公报\",\"FirstCategoryId\":\"1089\",\"ListUrlMain\":\"https://doi.org/10.1109/FCS.2015.7138963\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"时间频率公报","FirstCategoryId":"1089","ListUrlMain":"https://doi.org/10.1109/FCS.2015.7138963","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

激光时间传递是一种具有皮秒精度和几十皮秒级系统误差的极具吸引力的地面时间到空间时间传递技术。最近,欧洲激光计时实验正在欧洲航天局太空原子钟集合任务的框架内进行建设。这种激光时间转移的目标是使地面时钟与国际空间站上的时钟同步,具有皮秒精度和精度优于50皮秒。我们正在报告在识别和校准与地面和空间段相关的偏差方面取得的进展。为了表征地面段的延迟,已开发并测试了校准装置。它能够校准地面激光系统的系统定时偏差。因此,在ELT实验中,地对地时间传递的系统误差应不高于25皮秒。为了确定空间段的延迟,设计并测试了新的校准程序。校正测试结果将会公布。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Identification and calibration of ground system biases in ground to space laser time transfer
Laser time transfer is and attractive technique to transfer time ground to space with picosecond precision and systematic errors on the level of tens of picoseconds. Recently the European Laser Timing experiment is under construction in the frame of the European Space Agency mission Atomic Clock Ensemble in Space. The objective of this laser time transfer is synchronization of the ground based clocks and the clock on board the International Space Station with picosecond precision and the accuracy better than 50 picoseconds We are reporting on a progress in identification and calibration of the biases associated to both ground and space segment. To characterize the delays of a ground segment the Calibration Device has been developed and tested. It enables to calibrate the ground based laser systems for their systematic timing biases. As a result the ground to ground time transfer in an ELT experiment should be accomplished with systematic errors not higher than 25 picoseconds. To determine the delays of a space segment the new calibration procedure has been designed and tested as well. The calibration test results will be presented.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
1135
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信