Yanfang Zhao, Caifang Chu, Qinfu Zhang, Xiaojun Cheng, Yongxing Li, Xiaofang Luo, Bingchen Dong
{"title":"河南省被检查人群CT剂量调查与分析","authors":"Yanfang Zhao, Caifang Chu, Qinfu Zhang, Xiaojun Cheng, Yongxing Li, Xiaofang Luo, Bingchen Dong","doi":"10.3760/CMA.J.ISSN.0254-5098.2020.03.012","DOIUrl":null,"url":null,"abstract":"Objective \nTo study the level of doses which children and adults received from CT examinations in Henan province, and to explore the influencing factors, so as to provide basic data for the development of diagnostic reference (guidance) level for CT examination in China and related regions. \n \n \nMethods \nA total of 1 113 subjects, which have received examinations by 31 CT scanners separately in 7 cities of the province, were selected using stratified quota sampling method to carry out the dose survey, including basic information on subjects, equipment, scanning parameters, and dosimetry, etc. Typical effective dose was estimated by using dose conversion coefficient. \n \n \nResults \nIn the conventional CT scanning of head. The 75% of CTDIw for children aged 0-1, >1-5, >5-10 and >10-15 years were 32.2, 37.2, 43.0 and 46.7 mGy; 75% of DLP were 478.0, 572.0, 715.6 and 743.9 mGy·cm and effective doses were 5.26, 3.83, 2.86 and 2.38 mSv, respectively. In the routine chest scanning, 75% of CTDIw for children aged 0-1, >1-5, >5-10 and >10-15 years were all 9.3 mGy. The 75% of DLP were 141.7, 178.8, 224.0 and 238.7 mGy·cm; and effective doses were 5.53, 4.64 4.03 and 3.10 mSv, respectively. 75% of CTDIw for head, chest and abdomen of the adult subjects from CT examinations were 57.4, 16.2 and 19.4 mGy, respectively. The 75% of DLP were 818.3, 504.7 and 571.1 mGy·cm, respectively, and effective doses were 1.72, 7.07 and 8.57 mSv, respectively. \n \n \nConclusions \nAs the update of CT equipment, increasing progress in examination technology and rapid increase in CT application frequency, medical institutions should choose the scanning parameters with respect to various types of CT scanner to optimize the image quality and the radiation doses. The diagnostic reference level for CT examination should be improved, especially for children. \n \n \nKey words: \nCT; CT dose index; Dose length product; Effective dose; Diagnostic reference level","PeriodicalId":36403,"journal":{"name":"中华放射医学与防护杂志","volume":"12 1","pages":"227-232"},"PeriodicalIF":0.0000,"publicationDate":"2020-03-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Investigation and analysis of CT doses to examined individuals in Henan province\",\"authors\":\"Yanfang Zhao, Caifang Chu, Qinfu Zhang, Xiaojun Cheng, Yongxing Li, Xiaofang Luo, Bingchen Dong\",\"doi\":\"10.3760/CMA.J.ISSN.0254-5098.2020.03.012\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Objective \\nTo study the level of doses which children and adults received from CT examinations in Henan province, and to explore the influencing factors, so as to provide basic data for the development of diagnostic reference (guidance) level for CT examination in China and related regions. \\n \\n \\nMethods \\nA total of 1 113 subjects, which have received examinations by 31 CT scanners separately in 7 cities of the province, were selected using stratified quota sampling method to carry out the dose survey, including basic information on subjects, equipment, scanning parameters, and dosimetry, etc. Typical effective dose was estimated by using dose conversion coefficient. \\n \\n \\nResults \\nIn the conventional CT scanning of head. The 75% of CTDIw for children aged 0-1, >1-5, >5-10 and >10-15 years were 32.2, 37.2, 43.0 and 46.7 mGy; 75% of DLP were 478.0, 572.0, 715.6 and 743.9 mGy·cm and effective doses were 5.26, 3.83, 2.86 and 2.38 mSv, respectively. In the routine chest scanning, 75% of CTDIw for children aged 0-1, >1-5, >5-10 and >10-15 years were all 9.3 mGy. The 75% of DLP were 141.7, 178.8, 224.0 and 238.7 mGy·cm; and effective doses were 5.53, 4.64 4.03 and 3.10 mSv, respectively. 75% of CTDIw for head, chest and abdomen of the adult subjects from CT examinations were 57.4, 16.2 and 19.4 mGy, respectively. The 75% of DLP were 818.3, 504.7 and 571.1 mGy·cm, respectively, and effective doses were 1.72, 7.07 and 8.57 mSv, respectively. \\n \\n \\nConclusions \\nAs the update of CT equipment, increasing progress in examination technology and rapid increase in CT application frequency, medical institutions should choose the scanning parameters with respect to various types of CT scanner to optimize the image quality and the radiation doses. The diagnostic reference level for CT examination should be improved, especially for children. \\n \\n \\nKey words: \\nCT; CT dose index; Dose length product; Effective dose; Diagnostic reference level\",\"PeriodicalId\":36403,\"journal\":{\"name\":\"中华放射医学与防护杂志\",\"volume\":\"12 1\",\"pages\":\"227-232\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-03-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"中华放射医学与防护杂志\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3760/CMA.J.ISSN.0254-5098.2020.03.012\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"中华放射医学与防护杂志","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3760/CMA.J.ISSN.0254-5098.2020.03.012","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

目的了解河南省儿童和成人CT检查的剂量水平,并探讨影响因素,为制定中国及相关地区CT检查诊断参考(指导)水平提供基础数据。方法采用分层定额抽样的方法,在全省7个城市共选取1 113名接受过31台CT扫描仪单独检查的受试者进行剂量调查,调查内容包括受试者基本情况、设备、扫描参数、剂量学等。采用剂量转换系数估算典型有效剂量。结果头颅常规CT扫描。0-1岁、>1-5岁、>5-10岁和>10-15岁儿童CTDIw的75%分别为32.2、37.2、43.0和46.7 mGy;75%的DLP分别为478.0、572.0、715.6和743.9 mGy·cm,有效剂量分别为5.26、3.83、2.86和2.38 mSv。在常规胸部扫描中,0-1岁、>1-5岁、>5-10岁、>10-15岁儿童CTDIw的75%均为9.3 mGy。75%的DLP分别为141.7、178.8、224.0和238.7 mGy·cm;有效剂量分别为5.53、4.64、4.03和3.10毫西弗。成人头部、胸部和腹部CT检查CTDIw的75%分别为57.4、16.2和19.4 mGy。75%的DLP分别为818.3、504.7和571.1 mGy·cm,有效剂量分别为1.72、7.07和8.57 mSv。结论随着CT设备的更新、检查技术的不断进步和CT应用频率的快速增加,医疗机构应针对不同类型的CT扫描仪选择扫描参数,以优化图像质量和辐射剂量。应提高CT检查的诊断参考水平,尤其是儿童。关键词:CT;CT剂量指数;剂量长度积;有效剂量;诊断参考水平
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Investigation and analysis of CT doses to examined individuals in Henan province
Objective To study the level of doses which children and adults received from CT examinations in Henan province, and to explore the influencing factors, so as to provide basic data for the development of diagnostic reference (guidance) level for CT examination in China and related regions. Methods A total of 1 113 subjects, which have received examinations by 31 CT scanners separately in 7 cities of the province, were selected using stratified quota sampling method to carry out the dose survey, including basic information on subjects, equipment, scanning parameters, and dosimetry, etc. Typical effective dose was estimated by using dose conversion coefficient. Results In the conventional CT scanning of head. The 75% of CTDIw for children aged 0-1, >1-5, >5-10 and >10-15 years were 32.2, 37.2, 43.0 and 46.7 mGy; 75% of DLP were 478.0, 572.0, 715.6 and 743.9 mGy·cm and effective doses were 5.26, 3.83, 2.86 and 2.38 mSv, respectively. In the routine chest scanning, 75% of CTDIw for children aged 0-1, >1-5, >5-10 and >10-15 years were all 9.3 mGy. The 75% of DLP were 141.7, 178.8, 224.0 and 238.7 mGy·cm; and effective doses were 5.53, 4.64 4.03 and 3.10 mSv, respectively. 75% of CTDIw for head, chest and abdomen of the adult subjects from CT examinations were 57.4, 16.2 and 19.4 mGy, respectively. The 75% of DLP were 818.3, 504.7 and 571.1 mGy·cm, respectively, and effective doses were 1.72, 7.07 and 8.57 mSv, respectively. Conclusions As the update of CT equipment, increasing progress in examination technology and rapid increase in CT application frequency, medical institutions should choose the scanning parameters with respect to various types of CT scanner to optimize the image quality and the radiation doses. The diagnostic reference level for CT examination should be improved, especially for children. Key words: CT; CT dose index; Dose length product; Effective dose; Diagnostic reference level
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
中华放射医学与防护杂志
中华放射医学与防护杂志 Medicine-Radiology, Nuclear Medicine and Imaging
CiteScore
0.60
自引率
0.00%
发文量
6377
期刊介绍:
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信