E. Choi, Jung Woo Lee, C. Joh, J. Kwark, J. Kim, Yoongil Choi
{"title":"超高性能混凝土锚块后张筋局部压缩试验","authors":"E. Choi, Jung Woo Lee, C. Joh, J. Kwark, J. Kim, Yoongil Choi","doi":"10.4028/www.scientific.net/KEM.525-526.561","DOIUrl":null,"url":null,"abstract":"In the application of Ultra High Performance Concrete (UHPC) to PSC girders by using the post-tensioning system, the high strength and ductility of UHPC in tension can be exploited to substitute the confined reinforcing bars which control the rupture around the anchorage device. The exploitation of such properties is expected to simplify the reinforcing details around the anchorage zone. Taking advantage of UHPC can downsize a cross section with the attributes of high compression and tensile strength. This paper reports the local behavior of UHPC anchor block under compression. Test specimens were made based on mix proportion of K-UHPC (KICT-Ultra High Performance Concrete) developed by the Korea Institute of Construction Technology (KICT). The performance of the anchor block was evaluated according to ETAG-013 (European Technical Agreement Guide No.13) of EOTA (European Organization for Technical Approvals). As the results of the experiment, it is found that the details and reinforcement of UHPC anchorage zone can be simplified with the interconnection effect and the high intensity of the matrix itself.","PeriodicalId":17714,"journal":{"name":"Key Engineering Materials","volume":"30 1","pages":"561 - 564"},"PeriodicalIF":0.0000,"publicationDate":"2012-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"A Local Compression Tests of UHPC Anchor Blocks for Post-Tensioning Tendons\",\"authors\":\"E. Choi, Jung Woo Lee, C. Joh, J. Kwark, J. Kim, Yoongil Choi\",\"doi\":\"10.4028/www.scientific.net/KEM.525-526.561\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In the application of Ultra High Performance Concrete (UHPC) to PSC girders by using the post-tensioning system, the high strength and ductility of UHPC in tension can be exploited to substitute the confined reinforcing bars which control the rupture around the anchorage device. The exploitation of such properties is expected to simplify the reinforcing details around the anchorage zone. Taking advantage of UHPC can downsize a cross section with the attributes of high compression and tensile strength. This paper reports the local behavior of UHPC anchor block under compression. Test specimens were made based on mix proportion of K-UHPC (KICT-Ultra High Performance Concrete) developed by the Korea Institute of Construction Technology (KICT). The performance of the anchor block was evaluated according to ETAG-013 (European Technical Agreement Guide No.13) of EOTA (European Organization for Technical Approvals). As the results of the experiment, it is found that the details and reinforcement of UHPC anchorage zone can be simplified with the interconnection effect and the high intensity of the matrix itself.\",\"PeriodicalId\":17714,\"journal\":{\"name\":\"Key Engineering Materials\",\"volume\":\"30 1\",\"pages\":\"561 - 564\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Key Engineering Materials\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4028/www.scientific.net/KEM.525-526.561\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Key Engineering Materials","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4028/www.scientific.net/KEM.525-526.561","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
A Local Compression Tests of UHPC Anchor Blocks for Post-Tensioning Tendons
In the application of Ultra High Performance Concrete (UHPC) to PSC girders by using the post-tensioning system, the high strength and ductility of UHPC in tension can be exploited to substitute the confined reinforcing bars which control the rupture around the anchorage device. The exploitation of such properties is expected to simplify the reinforcing details around the anchorage zone. Taking advantage of UHPC can downsize a cross section with the attributes of high compression and tensile strength. This paper reports the local behavior of UHPC anchor block under compression. Test specimens were made based on mix proportion of K-UHPC (KICT-Ultra High Performance Concrete) developed by the Korea Institute of Construction Technology (KICT). The performance of the anchor block was evaluated according to ETAG-013 (European Technical Agreement Guide No.13) of EOTA (European Organization for Technical Approvals). As the results of the experiment, it is found that the details and reinforcement of UHPC anchorage zone can be simplified with the interconnection effect and the high intensity of the matrix itself.