定量冠状动脉造影:图像变焦和参考物体尺寸对直径测量的影响

T. Linderer, W. Wunderlich, F. Fischer, R. Schroder
{"title":"定量冠状动脉造影:图像变焦和参考物体尺寸对直径测量的影响","authors":"T. Linderer, W. Wunderlich, F. Fischer, R. Schroder","doi":"10.1109/CIC.1993.378336","DOIUrl":null,"url":null,"abstract":"The authors studied the effect various catheter sizes and floating image zoom on catheter calibrated vessel diameters. The pixel sizes of vessel phantoms (0.3-4.5 mm o) were obtained by optimum weighted edge detection. The 2.0 mm and the 3.0 mm phantom served as scaling device for catheter calibration. Image zoom varied from 1 to 6 fold. The authors found, that reference object calibration causes a rotation of measured native pixel diameter curves, whereby the amount of rotation depends on the size of the scaling catheter and affects especially diameters in the normal range of coronaries. It is concluded that using different catheter sizes and varying image zoom should be discouraged in long-term studies of coronary artery disease, since they feign non-existent lesion changes.<<ETX>>","PeriodicalId":20445,"journal":{"name":"Proceedings of Computers in Cardiology Conference","volume":"121 1","pages":"579-582"},"PeriodicalIF":0.0000,"publicationDate":"1993-09-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Quantitative coronary arteriography: the impact of image zoom and reference object size on diameter measurements\",\"authors\":\"T. Linderer, W. Wunderlich, F. Fischer, R. Schroder\",\"doi\":\"10.1109/CIC.1993.378336\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The authors studied the effect various catheter sizes and floating image zoom on catheter calibrated vessel diameters. The pixel sizes of vessel phantoms (0.3-4.5 mm o) were obtained by optimum weighted edge detection. The 2.0 mm and the 3.0 mm phantom served as scaling device for catheter calibration. Image zoom varied from 1 to 6 fold. The authors found, that reference object calibration causes a rotation of measured native pixel diameter curves, whereby the amount of rotation depends on the size of the scaling catheter and affects especially diameters in the normal range of coronaries. It is concluded that using different catheter sizes and varying image zoom should be discouraged in long-term studies of coronary artery disease, since they feign non-existent lesion changes.<<ETX>>\",\"PeriodicalId\":20445,\"journal\":{\"name\":\"Proceedings of Computers in Cardiology Conference\",\"volume\":\"121 1\",\"pages\":\"579-582\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1993-09-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Proceedings of Computers in Cardiology Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/CIC.1993.378336\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of Computers in Cardiology Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/CIC.1993.378336","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

研究了不同导管尺寸和浮动图像变焦对导管标定血管直径的影响。通过最优加权边缘检测,获得了血管影的像素大小(0.3 ~ 4.5 mm o)。2.0 mm和3.0 mm幻影作为导管校准的刻度装置。图像变焦从1到6倍不等。作者发现,参考对象校准引起测量的原生像素直径曲线的旋转,其中旋转的量取决于缩放导管的大小,特别是影响冠状动脉正常范围内的直径。因此,在冠状动脉疾病的长期研究中,不建议使用不同尺寸的导管和不同的图像变焦,因为它们会伪造不存在的病变改变
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Quantitative coronary arteriography: the impact of image zoom and reference object size on diameter measurements
The authors studied the effect various catheter sizes and floating image zoom on catheter calibrated vessel diameters. The pixel sizes of vessel phantoms (0.3-4.5 mm o) were obtained by optimum weighted edge detection. The 2.0 mm and the 3.0 mm phantom served as scaling device for catheter calibration. Image zoom varied from 1 to 6 fold. The authors found, that reference object calibration causes a rotation of measured native pixel diameter curves, whereby the amount of rotation depends on the size of the scaling catheter and affects especially diameters in the normal range of coronaries. It is concluded that using different catheter sizes and varying image zoom should be discouraged in long-term studies of coronary artery disease, since they feign non-existent lesion changes.<>
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信