{"title":"基于自适应神经模糊推理系统的输电线路聚合物绝缘子污染程度预测","authors":"C. Muniraj, S. Chandrasekar","doi":"10.1155/2011/431357","DOIUrl":null,"url":null,"abstract":"This paper presents the prediction of pollution severity of the polymeric insulators used in power transmission lines using adaptive neurofuzzy inference system (ANFIS) model. In this work, laboratory-based pollution performance tests were carried out on 11 kV silicone rubber polymeric insulator under AC voltage at different pollution levels with sodium chloride as a contaminant. Leakage current was measured during the laboratory tests. Time domain and frequency domain characteristics of leakage current, such as mean value, maximum value, standard deviation, and total harmonics distortion (THD), have been extracted, which jointly describe the pollution severity of the polymeric insulator surface. Leakage current characteristics are used as the inputs of ANFIS model. The pollution severity index \"equivalent salt deposit density\" (ESDD) is used as the output of the proposed model. Results of the research can give sufficient prewarning time before pollution flashover and help in the condition based maintenance (CBM) chart preparation.","PeriodicalId":7288,"journal":{"name":"Adv. Artif. Neural Syst.","volume":"2011 1","pages":"431357:1-431357:9"},"PeriodicalIF":0.0000,"publicationDate":"2011-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"7","resultStr":"{\"title\":\"Adaptive Neurofuzzy Inference System-Based Pollution Severity Prediction of Polymeric Insulators in Power Transmission Lines\",\"authors\":\"C. Muniraj, S. Chandrasekar\",\"doi\":\"10.1155/2011/431357\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents the prediction of pollution severity of the polymeric insulators used in power transmission lines using adaptive neurofuzzy inference system (ANFIS) model. In this work, laboratory-based pollution performance tests were carried out on 11 kV silicone rubber polymeric insulator under AC voltage at different pollution levels with sodium chloride as a contaminant. Leakage current was measured during the laboratory tests. Time domain and frequency domain characteristics of leakage current, such as mean value, maximum value, standard deviation, and total harmonics distortion (THD), have been extracted, which jointly describe the pollution severity of the polymeric insulator surface. Leakage current characteristics are used as the inputs of ANFIS model. The pollution severity index \\\"equivalent salt deposit density\\\" (ESDD) is used as the output of the proposed model. Results of the research can give sufficient prewarning time before pollution flashover and help in the condition based maintenance (CBM) chart preparation.\",\"PeriodicalId\":7288,\"journal\":{\"name\":\"Adv. Artif. Neural Syst.\",\"volume\":\"2011 1\",\"pages\":\"431357:1-431357:9\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Adv. Artif. Neural Syst.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1155/2011/431357\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Adv. Artif. Neural Syst.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2011/431357","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Adaptive Neurofuzzy Inference System-Based Pollution Severity Prediction of Polymeric Insulators in Power Transmission Lines
This paper presents the prediction of pollution severity of the polymeric insulators used in power transmission lines using adaptive neurofuzzy inference system (ANFIS) model. In this work, laboratory-based pollution performance tests were carried out on 11 kV silicone rubber polymeric insulator under AC voltage at different pollution levels with sodium chloride as a contaminant. Leakage current was measured during the laboratory tests. Time domain and frequency domain characteristics of leakage current, such as mean value, maximum value, standard deviation, and total harmonics distortion (THD), have been extracted, which jointly describe the pollution severity of the polymeric insulator surface. Leakage current characteristics are used as the inputs of ANFIS model. The pollution severity index "equivalent salt deposit density" (ESDD) is used as the output of the proposed model. Results of the research can give sufficient prewarning time before pollution flashover and help in the condition based maintenance (CBM) chart preparation.