一个简单的穿透仪

C. E. Bassey, J. J. Fletcher
{"title":"一个简单的穿透仪","authors":"C. E. Bassey, J. J. Fletcher","doi":"10.1088/0022-3735/22/10/016","DOIUrl":null,"url":null,"abstract":"A penetrameter, which is a device for checking the kVp calibration of an X-ray generator, has been designed and constructed in the University of Ilorin using locally available materials. The device consists of a 2 mm thick sheet of aluminium used as a beam hardener, stacks of various numbers of aluminium discs for beam attenuation, Perspex for support and an X-ray film cassette for detection. The identification of dots of equal optical density is made using a densitometer also made by one of the authors. The device has been tested in the Radiology department of the University of Ilorin Teaching Hospital on a diagnostic range X-ray machine and found to be satisfactory. It is simpler and less expensive than imported penetrameter cassettes.","PeriodicalId":16791,"journal":{"name":"Journal of Physics E: Scientific Instruments","volume":"30 1","pages":"882-883"},"PeriodicalIF":0.0000,"publicationDate":"1989-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"A simple penetrameter\",\"authors\":\"C. E. Bassey, J. J. Fletcher\",\"doi\":\"10.1088/0022-3735/22/10/016\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A penetrameter, which is a device for checking the kVp calibration of an X-ray generator, has been designed and constructed in the University of Ilorin using locally available materials. The device consists of a 2 mm thick sheet of aluminium used as a beam hardener, stacks of various numbers of aluminium discs for beam attenuation, Perspex for support and an X-ray film cassette for detection. The identification of dots of equal optical density is made using a densitometer also made by one of the authors. The device has been tested in the Radiology department of the University of Ilorin Teaching Hospital on a diagnostic range X-ray machine and found to be satisfactory. It is simpler and less expensive than imported penetrameter cassettes.\",\"PeriodicalId\":16791,\"journal\":{\"name\":\"Journal of Physics E: Scientific Instruments\",\"volume\":\"30 1\",\"pages\":\"882-883\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1989-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Physics E: Scientific Instruments\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1088/0022-3735/22/10/016\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Physics E: Scientific Instruments","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1088/0022-3735/22/10/016","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

在伊洛林大学使用当地可用的材料设计和制造了一种穿透仪,这是一种检查x射线发生器kVp校准的装置。该装置由2毫米厚的铝片组成,用作光束硬化剂,堆叠不同数量的铝盘用于光束衰减,有机玻璃作为支撑,以及用于检测的x射线胶片盒。用密度计对光密度相等的点进行了识别,密度计也是作者之一制作的。该装置已在伊洛林大学教学医院放射科的一台诊断范围x光机上进行了测试,结果令人满意。它比进口的穿透式磁带更简单,更便宜。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A simple penetrameter
A penetrameter, which is a device for checking the kVp calibration of an X-ray generator, has been designed and constructed in the University of Ilorin using locally available materials. The device consists of a 2 mm thick sheet of aluminium used as a beam hardener, stacks of various numbers of aluminium discs for beam attenuation, Perspex for support and an X-ray film cassette for detection. The identification of dots of equal optical density is made using a densitometer also made by one of the authors. The device has been tested in the Radiology department of the University of Ilorin Teaching Hospital on a diagnostic range X-ray machine and found to be satisfactory. It is simpler and less expensive than imported penetrameter cassettes.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信