疏水油水界面的电阻抗:非接触测量

Magdi H Saad, A. Bashal
{"title":"疏水油水界面的电阻抗:非接触测量","authors":"Magdi H Saad, A. Bashal","doi":"10.56293/ijasr.2022.5512","DOIUrl":null,"url":null,"abstract":"We have performed systematic contactless measurements aiming at the determination of the electrical impedance of an oil-water interface. The oil-water interface was formed within an insulin syringe tube due to the oil hydrophobicity. The measurement AC signal (0.1-300 kHz at 0.1 V) was capacitively coupled to the oil-water system through the syringe wall. The interface resistivity was estimated at ~2109m(assuming the interface as a slip layer with width ~ 10 nm) and was associated with hydroxide (OH–) ions, agreeing with existing reports. The resistivity was found to be independent on the signal frequency, which may indicate the nonpolarized nature of the hydrophobic interface. The present impedance spectroscopy is important for hydrophobic systems and may give an insight into the future nondestructive (contactless) investigation of the electrical properties of the lipid layer in the living cell membrane.","PeriodicalId":13763,"journal":{"name":"International Journal of Applied Science and Engineering Research","volume":"8 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Electrical impedance of the hydrophobic oil-water interface: contactless measurement\",\"authors\":\"Magdi H Saad, A. Bashal\",\"doi\":\"10.56293/ijasr.2022.5512\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We have performed systematic contactless measurements aiming at the determination of the electrical impedance of an oil-water interface. The oil-water interface was formed within an insulin syringe tube due to the oil hydrophobicity. The measurement AC signal (0.1-300 kHz at 0.1 V) was capacitively coupled to the oil-water system through the syringe wall. The interface resistivity was estimated at ~2109m(assuming the interface as a slip layer with width ~ 10 nm) and was associated with hydroxide (OH–) ions, agreeing with existing reports. The resistivity was found to be independent on the signal frequency, which may indicate the nonpolarized nature of the hydrophobic interface. The present impedance spectroscopy is important for hydrophobic systems and may give an insight into the future nondestructive (contactless) investigation of the electrical properties of the lipid layer in the living cell membrane.\",\"PeriodicalId\":13763,\"journal\":{\"name\":\"International Journal of Applied Science and Engineering Research\",\"volume\":\"8 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Applied Science and Engineering Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.56293/ijasr.2022.5512\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Applied Science and Engineering Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.56293/ijasr.2022.5512","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

为了确定油水界面的电阻抗,我们进行了系统的非接触测量。由于油的疏水性,在胰岛素注射管内形成油水界面。测量交流信号(0.1- 300khz, 0.1 V)通过注射器壁电容耦合到油水系统。界面电阻率估计为~2109 m(假设界面为宽度为~ 10 nm的滑移层),并与氢氧根(OH -)离子相关,与已有报道一致。发现电阻率与信号频率无关,这可能表明疏水界面的非极化性质。目前的阻抗谱对于疏水系统是重要的,并可能为未来对活细胞膜中脂质层电学性质的无损(非接触)研究提供见解。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Electrical impedance of the hydrophobic oil-water interface: contactless measurement
We have performed systematic contactless measurements aiming at the determination of the electrical impedance of an oil-water interface. The oil-water interface was formed within an insulin syringe tube due to the oil hydrophobicity. The measurement AC signal (0.1-300 kHz at 0.1 V) was capacitively coupled to the oil-water system through the syringe wall. The interface resistivity was estimated at ~2109m(assuming the interface as a slip layer with width ~ 10 nm) and was associated with hydroxide (OH–) ions, agreeing with existing reports. The resistivity was found to be independent on the signal frequency, which may indicate the nonpolarized nature of the hydrophobic interface. The present impedance spectroscopy is important for hydrophobic systems and may give an insight into the future nondestructive (contactless) investigation of the electrical properties of the lipid layer in the living cell membrane.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信