离线SMPS中前端整流器共模瞬变的影响

M. Sudheer, M. Gunasekaran
{"title":"离线SMPS中前端整流器共模瞬变的影响","authors":"M. Sudheer, M. Gunasekaran","doi":"10.1109/ISEMC.2005.1513537","DOIUrl":null,"url":null,"abstract":"This paper presents the effect of common mode (CM) transient on a typical front-end rectifier of offline power electronic equipment like switched mode power supply (SMPS) and near unity power factor (NUPF) converters. They undergo mode conversion to differential mode (DM) transients. The magnitude, rise time and fall time of such DM transients depend on the coupling capacitance to ground, rise time and position of occurrence of CM transients on AC mains voltage. This DM transient may damage sensitive components and may cause malfunctioning of the ICs used in the SMPS/NUPF circuitry. It will also cause interference in their output voltages. Connecting RC snubbers across the diode bridge can mitigate them. Simulation results, mathematical analysis and experimental results presented here are in close conformity.","PeriodicalId":6459,"journal":{"name":"2005 International Symposium on Electromagnetic Compatibility, 2005. EMC 2005.","volume":"16 1","pages":"346-349 Vol. 2"},"PeriodicalIF":0.0000,"publicationDate":"2005-10-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Effect of common mode transients on front end rectifiers in offline SMPS\",\"authors\":\"M. Sudheer, M. Gunasekaran\",\"doi\":\"10.1109/ISEMC.2005.1513537\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents the effect of common mode (CM) transient on a typical front-end rectifier of offline power electronic equipment like switched mode power supply (SMPS) and near unity power factor (NUPF) converters. They undergo mode conversion to differential mode (DM) transients. The magnitude, rise time and fall time of such DM transients depend on the coupling capacitance to ground, rise time and position of occurrence of CM transients on AC mains voltage. This DM transient may damage sensitive components and may cause malfunctioning of the ICs used in the SMPS/NUPF circuitry. It will also cause interference in their output voltages. Connecting RC snubbers across the diode bridge can mitigate them. Simulation results, mathematical analysis and experimental results presented here are in close conformity.\",\"PeriodicalId\":6459,\"journal\":{\"name\":\"2005 International Symposium on Electromagnetic Compatibility, 2005. EMC 2005.\",\"volume\":\"16 1\",\"pages\":\"346-349 Vol. 2\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2005-10-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2005 International Symposium on Electromagnetic Compatibility, 2005. EMC 2005.\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISEMC.2005.1513537\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2005 International Symposium on Electromagnetic Compatibility, 2005. EMC 2005.","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISEMC.2005.1513537","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

本文介绍了共模暂态对开关电源(SMPS)和近单位功率因数(NUPF)变换器等离线电力电子设备的典型前端整流器的影响。它们经历模式转换到差分模式(DM)瞬态。这种DM瞬态的幅度、上升时间和下降时间取决于对地耦合电容、交流市电电压上CM瞬态发生的上升时间和位置。这种DM瞬态可能会损坏敏感元件,并可能导致SMPS/NUPF电路中使用的ic故障。它还会对它们的输出电压造成干扰。通过二极管桥连接RC缓冲器可以减轻它们。本文给出的仿真结果、数学分析结果与实验结果吻合较好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Effect of common mode transients on front end rectifiers in offline SMPS
This paper presents the effect of common mode (CM) transient on a typical front-end rectifier of offline power electronic equipment like switched mode power supply (SMPS) and near unity power factor (NUPF) converters. They undergo mode conversion to differential mode (DM) transients. The magnitude, rise time and fall time of such DM transients depend on the coupling capacitance to ground, rise time and position of occurrence of CM transients on AC mains voltage. This DM transient may damage sensitive components and may cause malfunctioning of the ICs used in the SMPS/NUPF circuitry. It will also cause interference in their output voltages. Connecting RC snubbers across the diode bridge can mitigate them. Simulation results, mathematical analysis and experimental results presented here are in close conformity.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信