LC-MS/MS同时定量少量肝脏鞘脂。

Q3 Physics and Astronomy
D. Saigusa, Michiyo Okudaira, Jiao Wang, K. Kano, M. Kurano, B. Uranbileg, H. Ikeda, Y. Yatomi, H. Motohashi, J. Aoki
{"title":"LC-MS/MS同时定量少量肝脏鞘脂。","authors":"D. Saigusa, Michiyo Okudaira, Jiao Wang, K. Kano, M. Kurano, B. Uranbileg, H. Ikeda, Y. Yatomi, H. Motohashi, J. Aoki","doi":"10.5702/massspectrometry.S0046","DOIUrl":null,"url":null,"abstract":"Sph, S1P, and Cer, derived from the membrane sphingolipids, act as intracellular and intercellular mediators, involved in various (path) physiological functions. Accordingly, determining the distributions and concentrations of these sphingolipid mediators in body tissues is an important task. Consequently, a method for determination of sphingolipids in small quantities of tissue is required. Sphingolipids analysis has been dependent on improvements in mass spectrometry (MS) technology. Additionally, decomposition of sphingosine-1-phosphate (S1P) in the tissue samples before preparation for MS has hindered analysis. In the present study, a method for stabilization of liver samples before MS preparation was developed using a heat stabilizer (Stabilizor™ T1). Then, a LC-MS/MS method using a triple-quadrupole mass spectrometer with a C8 column was developed for simultaneous determination of sphingolipids in small quantities of liver specimens. This method showed good separation and validation results. Separation was performed with a gradient elution of solvent A (5 mmol L(-1) ammonium formate in water, pH 4.0) and solvent B (5 mmol L(-1) ammonium formate in 95% acetonitrile, pH 4.0) at 300 μL min(-1). The lower limit of quantification was less than 132 pmol L(-1), and this method was accurate (∼13.5%) and precise (∼7.13%) for S1P analysis. The method can be used to show the tissue distribution of sphingolipids.","PeriodicalId":18243,"journal":{"name":"Mass spectrometry","volume":"37 1","pages":"S0046"},"PeriodicalIF":0.0000,"publicationDate":"2014-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"17","resultStr":"{\"title\":\"Simultaneous Quantification of Sphingolipids in Small Quantities of Liver by LC-MS/MS.\",\"authors\":\"D. Saigusa, Michiyo Okudaira, Jiao Wang, K. Kano, M. Kurano, B. Uranbileg, H. Ikeda, Y. Yatomi, H. Motohashi, J. Aoki\",\"doi\":\"10.5702/massspectrometry.S0046\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Sph, S1P, and Cer, derived from the membrane sphingolipids, act as intracellular and intercellular mediators, involved in various (path) physiological functions. Accordingly, determining the distributions and concentrations of these sphingolipid mediators in body tissues is an important task. Consequently, a method for determination of sphingolipids in small quantities of tissue is required. Sphingolipids analysis has been dependent on improvements in mass spectrometry (MS) technology. Additionally, decomposition of sphingosine-1-phosphate (S1P) in the tissue samples before preparation for MS has hindered analysis. In the present study, a method for stabilization of liver samples before MS preparation was developed using a heat stabilizer (Stabilizor™ T1). Then, a LC-MS/MS method using a triple-quadrupole mass spectrometer with a C8 column was developed for simultaneous determination of sphingolipids in small quantities of liver specimens. This method showed good separation and validation results. Separation was performed with a gradient elution of solvent A (5 mmol L(-1) ammonium formate in water, pH 4.0) and solvent B (5 mmol L(-1) ammonium formate in 95% acetonitrile, pH 4.0) at 300 μL min(-1). The lower limit of quantification was less than 132 pmol L(-1), and this method was accurate (∼13.5%) and precise (∼7.13%) for S1P analysis. The method can be used to show the tissue distribution of sphingolipids.\",\"PeriodicalId\":18243,\"journal\":{\"name\":\"Mass spectrometry\",\"volume\":\"37 1\",\"pages\":\"S0046\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2014-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"17\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Mass spectrometry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5702/massspectrometry.S0046\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Physics and Astronomy\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Mass spectrometry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5702/massspectrometry.S0046","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Physics and Astronomy","Score":null,"Total":0}
引用次数: 17

摘要

Sph, S1P和Cer来源于鞘膜脂,作为细胞内和细胞间介质,参与多种(途径)生理功能。因此,确定这些鞘脂介质在机体组织中的分布和浓度是一项重要的任务。因此,需要一种测定少量组织中鞘脂的方法。鞘脂分析一直依赖于质谱(MS)技术的改进。此外,MS前组织样品中鞘氨醇-1-磷酸(S1P)的分解也阻碍了分析。在本研究中,开发了一种在质谱制备前使用热稳定剂(Stabilizor™T1)稳定肝脏样品的方法。然后,建立了采用C8柱三重四极杆质谱仪的LC-MS/MS同时测定少量肝脏标本鞘脂的方法。该方法具有良好的分离效果和验证效果。溶剂a (5 mmol L(-1)甲酸铵在水中,pH为4.0)和溶剂B (5 mmol L(-1)甲酸铵在95%乙腈中,pH为4.0)以300 μL min(-1)梯度洗脱进行分离。定量下限小于132 pmol L(-1),该方法对S1P分析具有准确度(~ 13.5%)和精密度(~ 7.13%)。该方法可显示鞘脂的组织分布。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Simultaneous Quantification of Sphingolipids in Small Quantities of Liver by LC-MS/MS.
Sph, S1P, and Cer, derived from the membrane sphingolipids, act as intracellular and intercellular mediators, involved in various (path) physiological functions. Accordingly, determining the distributions and concentrations of these sphingolipid mediators in body tissues is an important task. Consequently, a method for determination of sphingolipids in small quantities of tissue is required. Sphingolipids analysis has been dependent on improvements in mass spectrometry (MS) technology. Additionally, decomposition of sphingosine-1-phosphate (S1P) in the tissue samples before preparation for MS has hindered analysis. In the present study, a method for stabilization of liver samples before MS preparation was developed using a heat stabilizer (Stabilizor™ T1). Then, a LC-MS/MS method using a triple-quadrupole mass spectrometer with a C8 column was developed for simultaneous determination of sphingolipids in small quantities of liver specimens. This method showed good separation and validation results. Separation was performed with a gradient elution of solvent A (5 mmol L(-1) ammonium formate in water, pH 4.0) and solvent B (5 mmol L(-1) ammonium formate in 95% acetonitrile, pH 4.0) at 300 μL min(-1). The lower limit of quantification was less than 132 pmol L(-1), and this method was accurate (∼13.5%) and precise (∼7.13%) for S1P analysis. The method can be used to show the tissue distribution of sphingolipids.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Mass spectrometry
Mass spectrometry Physics and Astronomy-Instrumentation
CiteScore
1.90
自引率
0.00%
发文量
3
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信