高计数率的伽马光谱与大体积锗探测器

Nello Taccetti
{"title":"高计数率的伽马光谱与大体积锗探测器","authors":"Nello Taccetti","doi":"10.1016/0167-5087(84)91346-2","DOIUrl":null,"url":null,"abstract":"<div><p>The energy resolution and the throughput rate of a quasi-trapezoidal filter, based on a modified version of the DL-RC circuit, have been studied as a function of the counting rate up to ∼10<sup>5</sup> counts per second.</p><p>The performance of the modified DL-RC circuit is compared with that of a semi-Gaussian active filter and that of a quasi-trapezoidal gated integrator.</p></div>","PeriodicalId":100972,"journal":{"name":"Nuclear Instruments and Methods in Physics Research","volume":"225 1","pages":"Pages 118-121"},"PeriodicalIF":0.0000,"publicationDate":"1984-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0167-5087(84)91346-2","citationCount":"3","resultStr":"{\"title\":\"Gamma spectroscopy at high counting rates with large volume germanium detectors\",\"authors\":\"Nello Taccetti\",\"doi\":\"10.1016/0167-5087(84)91346-2\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The energy resolution and the throughput rate of a quasi-trapezoidal filter, based on a modified version of the DL-RC circuit, have been studied as a function of the counting rate up to ∼10<sup>5</sup> counts per second.</p><p>The performance of the modified DL-RC circuit is compared with that of a semi-Gaussian active filter and that of a quasi-trapezoidal gated integrator.</p></div>\",\"PeriodicalId\":100972,\"journal\":{\"name\":\"Nuclear Instruments and Methods in Physics Research\",\"volume\":\"225 1\",\"pages\":\"Pages 118-121\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1984-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/0167-5087(84)91346-2\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Nuclear Instruments and Methods in Physics Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/0167508784913462\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Nuclear Instruments and Methods in Physics Research","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/0167508784913462","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3

摘要

基于DL-RC电路的改进版本的准梯形滤波器的能量分辨率和吞吐量已被研究为高达每秒105个计数率的函数。将改进DL-RC电路的性能与半高斯有源滤波器和准梯形门控积分器的性能进行了比较。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Gamma spectroscopy at high counting rates with large volume germanium detectors

The energy resolution and the throughput rate of a quasi-trapezoidal filter, based on a modified version of the DL-RC circuit, have been studied as a function of the counting rate up to ∼105 counts per second.

The performance of the modified DL-RC circuit is compared with that of a semi-Gaussian active filter and that of a quasi-trapezoidal gated integrator.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信