{"title":"三聚氰胺检测用纸微流体装置","authors":"Wu Rg, Zhong Zw, Ankit, Chee Jy, C. Wang, Funk Kf","doi":"10.15761/HPC.1000199","DOIUrl":null,"url":null,"abstract":"A study of the paper-based microfluidic devices was carried out for melamine detection. Paper-based microfluidic detection was chosen for the experiments, as it could be the most cost effective, compared to other detection techniques, which would require expensive instruments. Experimental results revealed a very good depletion of bovine serum albumin from the target analyte (melamine). UV-vis absorbance value curves of the mixture solution and extraction solution showed the extraction of the small molecule (melamine) by the developed paper microfluidic device. It is concluded that the H-filter can be used for determination of adulterated melamine in dairy products.","PeriodicalId":48703,"journal":{"name":"Primary Health Care Research and Development","volume":"58 1","pages":""},"PeriodicalIF":1.6000,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Melamine detection using a paper microfluidic device\",\"authors\":\"Wu Rg, Zhong Zw, Ankit, Chee Jy, C. Wang, Funk Kf\",\"doi\":\"10.15761/HPC.1000199\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A study of the paper-based microfluidic devices was carried out for melamine detection. Paper-based microfluidic detection was chosen for the experiments, as it could be the most cost effective, compared to other detection techniques, which would require expensive instruments. Experimental results revealed a very good depletion of bovine serum albumin from the target analyte (melamine). UV-vis absorbance value curves of the mixture solution and extraction solution showed the extraction of the small molecule (melamine) by the developed paper microfluidic device. It is concluded that the H-filter can be used for determination of adulterated melamine in dairy products.\",\"PeriodicalId\":48703,\"journal\":{\"name\":\"Primary Health Care Research and Development\",\"volume\":\"58 1\",\"pages\":\"\"},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2020-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Primary Health Care Research and Development\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.15761/HPC.1000199\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"PRIMARY HEALTH CARE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Primary Health Care Research and Development","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.15761/HPC.1000199","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"PRIMARY HEALTH CARE","Score":null,"Total":0}
引用次数: 1

摘要

对纸基微流控装置进行了三聚氰胺检测研究。实验选择基于纸张的微流体检测,因为与需要昂贵仪器的其他检测技术相比,它可能是最具成本效益的。实验结果显示牛血清白蛋白从目标分析物(三聚氰胺)中损耗非常好。混合液和萃取液的紫外可见吸光度曲线显示了所研制的纸微流控装置对小分子(三聚氰胺)的提取效果。结果表明,h型过滤器可用于乳制品中掺假三聚氰胺的检测。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Melamine detection using a paper microfluidic device
A study of the paper-based microfluidic devices was carried out for melamine detection. Paper-based microfluidic detection was chosen for the experiments, as it could be the most cost effective, compared to other detection techniques, which would require expensive instruments. Experimental results revealed a very good depletion of bovine serum albumin from the target analyte (melamine). UV-vis absorbance value curves of the mixture solution and extraction solution showed the extraction of the small molecule (melamine) by the developed paper microfluidic device. It is concluded that the H-filter can be used for determination of adulterated melamine in dairy products.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.60
自引率
6.20%
发文量
119
审稿时长
33 weeks
期刊介绍: Primary Health Care Research & Development is aimed specifically at both researchers and practitioners in primary health care, bridging the gap between the two areas. It provides a forum for the publication of international, interdisciplinary research and development in primary health care. It is essential reading for all involved in primary care: nurse practitioners, GPs and health service managers; professional and local groups in community health; researchers and academics; purchasers of primary health care services; allied health practitioners in secondary services and health-related consumer groups.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信