A. Ramkumar, X. Chen, D. Paduch, P.N. Schlegel, A. Lai
{"title":"微解剖双探针睾丸小管试验","authors":"A. Ramkumar, X. Chen, D. Paduch, P.N. Schlegel, A. Lai","doi":"10.1109/SENSOR.2007.4300544","DOIUrl":null,"url":null,"abstract":"We report on a microfabricated silicon probe integrated with an ultrasonic actuator and polysilicon strain gauges for Microdissection TEsticular Sperm Extraction (TESE) surgery. Insertion experiment was performed on rat testis tissue and by sensing the strain we were able to ascertain the size of the sperm-carrying microtubules in the sample. This information is important in Microdissection TESE to distinguish tubules with and without fertile sperm, eliminating large incision currently required for optical spermatazoa localization. Experimental data on tissue rigidity measurements indicate that the micromechanical assay can also be used for minimally-invasive testicular cancer detection.","PeriodicalId":23295,"journal":{"name":"TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2007-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Micro-Dissecting Dual-Probe Testicular Tubule Assay\",\"authors\":\"A. Ramkumar, X. Chen, D. Paduch, P.N. Schlegel, A. Lai\",\"doi\":\"10.1109/SENSOR.2007.4300544\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We report on a microfabricated silicon probe integrated with an ultrasonic actuator and polysilicon strain gauges for Microdissection TEsticular Sperm Extraction (TESE) surgery. Insertion experiment was performed on rat testis tissue and by sensing the strain we were able to ascertain the size of the sperm-carrying microtubules in the sample. This information is important in Microdissection TESE to distinguish tubules with and without fertile sperm, eliminating large incision currently required for optical spermatazoa localization. Experimental data on tissue rigidity measurements indicate that the micromechanical assay can also be used for minimally-invasive testicular cancer detection.\",\"PeriodicalId\":23295,\"journal\":{\"name\":\"TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-06-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/SENSOR.2007.4300544\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"TRANSDUCERS 2007 - 2007 International Solid-State Sensors, Actuators and Microsystems Conference","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SENSOR.2007.4300544","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

我们报道了一种集成了超声致动器和多晶硅应变片的微加工硅探针,用于显微解剖睾丸精子提取(TESE)手术。在大鼠睾丸组织上进行了插入实验,通过检测菌株,我们能够确定样品中携带精子的微管的大小。该信息在显微解剖TESE中很重要,可以区分有和没有可育精子的小管,消除了目前光学精子定位所需的大切口。组织刚度测量的实验数据表明,微力学分析也可用于微创睾丸癌检测。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Micro-Dissecting Dual-Probe Testicular Tubule Assay
We report on a microfabricated silicon probe integrated with an ultrasonic actuator and polysilicon strain gauges for Microdissection TEsticular Sperm Extraction (TESE) surgery. Insertion experiment was performed on rat testis tissue and by sensing the strain we were able to ascertain the size of the sperm-carrying microtubules in the sample. This information is important in Microdissection TESE to distinguish tubules with and without fertile sperm, eliminating large incision currently required for optical spermatazoa localization. Experimental data on tissue rigidity measurements indicate that the micromechanical assay can also be used for minimally-invasive testicular cancer detection.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信