{"title":"灌层常规水冷却温度的计算","authors":"N. Usmonov, S. Sanayev, Z. Yusupov","doi":"10.51346/tstu-01.19.3.-77-0036","DOIUrl":null,"url":null,"abstract":"The article describes the developed mathematical model, algorithm and program for calculating the process of cooling the water leaving the evaporative cooler and the final temperature of humid air. The compilation of a mathematical model is based on the analysis of literature data. Practically at all industrial enterprises, technological equipment is cooled by means of circulating water supply systems equipped with evaporative coolers. The article made a choice of a cooling system for air conditioning systems of residential premises. The developed basic design scheme of the evaporative water and air cooler with the irrigated layer is presented, as well as the estimated thermal and material balance. One of the main elements of these devices is a heat-mass transfer nozzle - sprinkler. This article presents the results of mathematical modeling of processes occurring in the volume of the sprinkler evaporator chamber, Raschig rings composed of vertical polymeric materials. Expressions are obtained for determining the values of air temperature based on the calculation of thermal modeling of the process of cooling circulating water in evaporative coolers of the type in question.","PeriodicalId":22199,"journal":{"name":"Technical science and innovation","volume":"62 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"CALCULATION OF TEMPERATURE OF ROUTINE WATER COOLED IN IRRIGATED LAYERS\",\"authors\":\"N. Usmonov, S. Sanayev, Z. Yusupov\",\"doi\":\"10.51346/tstu-01.19.3.-77-0036\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The article describes the developed mathematical model, algorithm and program for calculating the process of cooling the water leaving the evaporative cooler and the final temperature of humid air. The compilation of a mathematical model is based on the analysis of literature data. Practically at all industrial enterprises, technological equipment is cooled by means of circulating water supply systems equipped with evaporative coolers. The article made a choice of a cooling system for air conditioning systems of residential premises. The developed basic design scheme of the evaporative water and air cooler with the irrigated layer is presented, as well as the estimated thermal and material balance. One of the main elements of these devices is a heat-mass transfer nozzle - sprinkler. This article presents the results of mathematical modeling of processes occurring in the volume of the sprinkler evaporator chamber, Raschig rings composed of vertical polymeric materials. Expressions are obtained for determining the values of air temperature based on the calculation of thermal modeling of the process of cooling circulating water in evaporative coolers of the type in question.\",\"PeriodicalId\":22199,\"journal\":{\"name\":\"Technical science and innovation\",\"volume\":\"62 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Technical science and innovation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.51346/tstu-01.19.3.-77-0036\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Technical science and innovation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.51346/tstu-01.19.3.-77-0036","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
CALCULATION OF TEMPERATURE OF ROUTINE WATER COOLED IN IRRIGATED LAYERS
The article describes the developed mathematical model, algorithm and program for calculating the process of cooling the water leaving the evaporative cooler and the final temperature of humid air. The compilation of a mathematical model is based on the analysis of literature data. Practically at all industrial enterprises, technological equipment is cooled by means of circulating water supply systems equipped with evaporative coolers. The article made a choice of a cooling system for air conditioning systems of residential premises. The developed basic design scheme of the evaporative water and air cooler with the irrigated layer is presented, as well as the estimated thermal and material balance. One of the main elements of these devices is a heat-mass transfer nozzle - sprinkler. This article presents the results of mathematical modeling of processes occurring in the volume of the sprinkler evaporator chamber, Raschig rings composed of vertical polymeric materials. Expressions are obtained for determining the values of air temperature based on the calculation of thermal modeling of the process of cooling circulating water in evaporative coolers of the type in question.