{"title":"液-液萃取法","authors":"Sanjiv V. Save,&nbsp;Vishwas G. Pangarkar,&nbsp;S.Vasant Kumar","doi":"10.1016/0956-9618(94)80011-1","DOIUrl":null,"url":null,"abstract":"<div><p>The performance of continuous countercurrent predispersed solvent extraction (PDSE) using liquid aphrons (LA) and colloidal gas aphrons (CGA) has been studied for extraction of copper from aqueous acidic solution in LIX 622/kerosene and extraction of aqueous acetic acid in Alamine 336/2-ethyl hexanol. The effect of LA dilution at various levels along with the effect of relevant variables like LA, CGA and continuous-phase flow rates, type of LA etc. on extraction efficiency has been studied. The results indicate that the twofold dilution LA type gives the best efficiency vs. fivefold and no dilution LA type, and that the mass-transfer performance of PDSE is significantly better than conventional spray column. These results further indicate the potential for use of PDSE for other extraction applications.</p></div>","PeriodicalId":101160,"journal":{"name":"Separations Technology","volume":"4 2","pages":"Pages 104-111"},"PeriodicalIF":0.0000,"publicationDate":"1994-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0956-9618(94)80011-1","citationCount":"17","resultStr":"{\"title\":\"Liquid-liquid extraction using aphrons\",\"authors\":\"Sanjiv V. Save,&nbsp;Vishwas G. Pangarkar,&nbsp;S.Vasant Kumar\",\"doi\":\"10.1016/0956-9618(94)80011-1\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The performance of continuous countercurrent predispersed solvent extraction (PDSE) using liquid aphrons (LA) and colloidal gas aphrons (CGA) has been studied for extraction of copper from aqueous acidic solution in LIX 622/kerosene and extraction of aqueous acetic acid in Alamine 336/2-ethyl hexanol. The effect of LA dilution at various levels along with the effect of relevant variables like LA, CGA and continuous-phase flow rates, type of LA etc. on extraction efficiency has been studied. The results indicate that the twofold dilution LA type gives the best efficiency vs. fivefold and no dilution LA type, and that the mass-transfer performance of PDSE is significantly better than conventional spray column. These results further indicate the potential for use of PDSE for other extraction applications.</p></div>\",\"PeriodicalId\":101160,\"journal\":{\"name\":\"Separations Technology\",\"volume\":\"4 2\",\"pages\":\"Pages 104-111\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1994-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/0956-9618(94)80011-1\",\"citationCount\":\"17\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Separations Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/0956961894800111\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Separations Technology","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/0956961894800111","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 17

摘要

研究了液体阿芙龙(LA)和胶体气体阿芙龙(CGA)连续逆流预分散溶剂萃取(PDSE)在LIX 622/煤油酸性水溶液中萃取铜和Alamine 336/2-乙基己醇乙酸中的萃取性能。研究了不同浓度的LA稀释对萃取效率的影响,以及LA、CGA、连续相流速率、LA类型等相关变量对萃取效率的影响。结果表明,两倍稀释LA型比五倍和不稀释LA型效率最高,PDSE的传质性能明显优于常规喷雾柱。这些结果进一步表明了PDSE在其他提取应用中的潜力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Liquid-liquid extraction using aphrons

The performance of continuous countercurrent predispersed solvent extraction (PDSE) using liquid aphrons (LA) and colloidal gas aphrons (CGA) has been studied for extraction of copper from aqueous acidic solution in LIX 622/kerosene and extraction of aqueous acetic acid in Alamine 336/2-ethyl hexanol. The effect of LA dilution at various levels along with the effect of relevant variables like LA, CGA and continuous-phase flow rates, type of LA etc. on extraction efficiency has been studied. The results indicate that the twofold dilution LA type gives the best efficiency vs. fivefold and no dilution LA type, and that the mass-transfer performance of PDSE is significantly better than conventional spray column. These results further indicate the potential for use of PDSE for other extraction applications.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信