用cr39驻极体进行剂量测定的可能性

L. Makovická, B. Guille, A. Moliton, J. Teyssier
{"title":"用cr39驻极体进行剂量测定的可能性","authors":"L. Makovická, B. Guille, A. Moliton, J. Teyssier","doi":"10.1109/ISE.1985.7341558","DOIUrl":null,"url":null,"abstract":"A preliminary study enabled us, following a comparison with other electrets classically recognized as such (PE, PTFE, etc.), to show the interesting behaviour of the CR 39 (which is an allyl diglycol carbonate principally utilised as a solid state track detector) as an electret. Charged by Corona method and placed in a Faraday cage, conservation of the charges situates CR 39 between the classical electrets teflon and mylar. We studied the response (in charge terms) of the CR 39 submitted to an X radiation of average energy (77 keV) for dose between O and 8 rads. The discharge curves obtained are very significant and they enable us to prove the possibility of using the CR 39 in electret dosimetry.","PeriodicalId":6451,"journal":{"name":"1985 5th International Symposium on Electrets (ISE 5)","volume":"15 1","pages":"690-695"},"PeriodicalIF":0.0000,"publicationDate":"1985-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Possibility of using CR 39 electret in dosimetry\",\"authors\":\"L. Makovická, B. Guille, A. Moliton, J. Teyssier\",\"doi\":\"10.1109/ISE.1985.7341558\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"A preliminary study enabled us, following a comparison with other electrets classically recognized as such (PE, PTFE, etc.), to show the interesting behaviour of the CR 39 (which is an allyl diglycol carbonate principally utilised as a solid state track detector) as an electret. Charged by Corona method and placed in a Faraday cage, conservation of the charges situates CR 39 between the classical electrets teflon and mylar. We studied the response (in charge terms) of the CR 39 submitted to an X radiation of average energy (77 keV) for dose between O and 8 rads. The discharge curves obtained are very significant and they enable us to prove the possibility of using the CR 39 in electret dosimetry.\",\"PeriodicalId\":6451,\"journal\":{\"name\":\"1985 5th International Symposium on Electrets (ISE 5)\",\"volume\":\"15 1\",\"pages\":\"690-695\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1985-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"1985 5th International Symposium on Electrets (ISE 5)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ISE.1985.7341558\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"1985 5th International Symposium on Electrets (ISE 5)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ISE.1985.7341558","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

一项初步研究使我们能够与其他经典公认的驻极体(PE, PTFE等)进行比较,以显示CR 39(主要用作固态轨迹探测器的烯丙基碳酸二甘醇)作为驻极体的有趣行为。通过电晕法充电并放置在法拉第笼中,电荷守恒将cr39置于经典驻极体特氟龙和聚酯薄膜之间。我们研究了CR 39在0至8拉德的平均能量(77 keV) X辐射下的响应(电荷项)。所得的放电曲线非常显著,证明了在驻极体剂量学中使用cr39的可能性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Possibility of using CR 39 electret in dosimetry
A preliminary study enabled us, following a comparison with other electrets classically recognized as such (PE, PTFE, etc.), to show the interesting behaviour of the CR 39 (which is an allyl diglycol carbonate principally utilised as a solid state track detector) as an electret. Charged by Corona method and placed in a Faraday cage, conservation of the charges situates CR 39 between the classical electrets teflon and mylar. We studied the response (in charge terms) of the CR 39 submitted to an X radiation of average energy (77 keV) for dose between O and 8 rads. The discharge curves obtained are very significant and they enable us to prove the possibility of using the CR 39 in electret dosimetry.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信