尼日利亚西南部拉各斯Oniru Lekki拟建广场建筑的地下完整性评估,使用土工和岩土工程方法进行调查

Adegbite Joseph Taye, Adeoti Lukumon, Johnson Temitayo Olatilewa, Anukwu Geraldine Chibuzo, Adeleke Taofik
{"title":"尼日利亚西南部拉各斯Oniru Lekki拟建广场建筑的地下完整性评估,使用土工和岩土工程方法进行调查","authors":"Adegbite Joseph Taye, Adeoti Lukumon, Johnson Temitayo Olatilewa, Anukwu Geraldine Chibuzo, Adeleke Taofik","doi":"10.53848/ssstj.v10i1.425","DOIUrl":null,"url":null,"abstract":"Subsurface integrity assessment for building foundation using geophysical and geotechnical methods was carried out at Oniru, Eti- Osa, Lagos State. A total of twenty-five Vertical Electrical Sounding (VES), five 2-D Resistivity Imaging Survey traverses and two borings with Standard Penetration Test (SPT) were carried out at the study site. The acquired data were processed quantitatively using partial curve matching and computer iteration technique to generate the geoelectric sections, the 2-D model and the SPT logs. The VES results revealed five to six geologic units corresponding to topsoil, clayey sand, sandy clay, clay/peat, and sand while the 2-D resistivity structure corresponds with the VES result. The borehole log reveals sand layers having an N-value of 22-30 which is indicative of medium-dense, brown (medium to fine) sand with occasional gravels from depth 1.50 - 7.50m. The borehole log information correlates well with the VES/2-D result. For the sand layer which connotes dense, grey (medium to fine) sand with occasional gravels from a depth 7.50 – 15.75m with N-value ranging from 26–30m. The study analysis shows that the proposed building could be placed on the dense sand at depth 7.50 – 15.75m, this, however, should depend on the proposed load, length, and breadth of the proposed building. This study has provided useful information about the subsurface condition for engineering structure and zone suitable for the proposed foundation.","PeriodicalId":31349,"journal":{"name":"Suan Sunandha Rajabhat University Journal of Science and Technology","volume":"51 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-01-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Subsurface Integrity Assessments of a Proposed Plaza Building at Oniru Lekki, Lagos, South-western Nigeria, Using Geoelectrical and Geotechnical Methods of Investigations\",\"authors\":\"Adegbite Joseph Taye, Adeoti Lukumon, Johnson Temitayo Olatilewa, Anukwu Geraldine Chibuzo, Adeleke Taofik\",\"doi\":\"10.53848/ssstj.v10i1.425\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Subsurface integrity assessment for building foundation using geophysical and geotechnical methods was carried out at Oniru, Eti- Osa, Lagos State. A total of twenty-five Vertical Electrical Sounding (VES), five 2-D Resistivity Imaging Survey traverses and two borings with Standard Penetration Test (SPT) were carried out at the study site. The acquired data were processed quantitatively using partial curve matching and computer iteration technique to generate the geoelectric sections, the 2-D model and the SPT logs. The VES results revealed five to six geologic units corresponding to topsoil, clayey sand, sandy clay, clay/peat, and sand while the 2-D resistivity structure corresponds with the VES result. The borehole log reveals sand layers having an N-value of 22-30 which is indicative of medium-dense, brown (medium to fine) sand with occasional gravels from depth 1.50 - 7.50m. The borehole log information correlates well with the VES/2-D result. For the sand layer which connotes dense, grey (medium to fine) sand with occasional gravels from a depth 7.50 – 15.75m with N-value ranging from 26–30m. The study analysis shows that the proposed building could be placed on the dense sand at depth 7.50 – 15.75m, this, however, should depend on the proposed load, length, and breadth of the proposed building. This study has provided useful information about the subsurface condition for engineering structure and zone suitable for the proposed foundation.\",\"PeriodicalId\":31349,\"journal\":{\"name\":\"Suan Sunandha Rajabhat University Journal of Science and Technology\",\"volume\":\"51 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-01-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Suan Sunandha Rajabhat University Journal of Science and Technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.53848/ssstj.v10i1.425\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Suan Sunandha Rajabhat University Journal of Science and Technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.53848/ssstj.v10i1.425","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

利用地球物理和岩土工程方法对拉各斯州Eti- Osa的Oniru建筑基础进行了地下完整性评估。在研究地点共进行了25次垂直电测深(VES)、5次二维电阻率成像测量穿越和2次标准穿透试验(SPT)钻孔。利用局部曲线拟合和计算机迭代技术对获取的数据进行定量处理,生成地电剖面、二维模型和SPT测井曲线。探测结果显示了表土、粘砂、砂质粘土、粘土/泥炭、砂土等5 ~ 6个地质单元,二维电阻率结构与探测结果相对应。井眼测井显示砂层的n值为22-30,表明砂层为中等密度的棕色(中至细)砂,深度为1.50 - 7.5 m,偶有砾石。井眼测井信息与VES/ 2d结果吻合良好。砂层为致密的灰色(中细)砂,偶尔有砾石,深度为7.50 - 15.75m, n值为26-30m。研究分析表明,拟建建筑可建在深度为7.50 ~ 15.75m的密砂上,但这取决于拟建建筑的荷载、长度和宽度。该研究为工程结构的地下条件和拟建基础的适宜区域提供了有益的信息。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Subsurface Integrity Assessments of a Proposed Plaza Building at Oniru Lekki, Lagos, South-western Nigeria, Using Geoelectrical and Geotechnical Methods of Investigations
Subsurface integrity assessment for building foundation using geophysical and geotechnical methods was carried out at Oniru, Eti- Osa, Lagos State. A total of twenty-five Vertical Electrical Sounding (VES), five 2-D Resistivity Imaging Survey traverses and two borings with Standard Penetration Test (SPT) were carried out at the study site. The acquired data were processed quantitatively using partial curve matching and computer iteration technique to generate the geoelectric sections, the 2-D model and the SPT logs. The VES results revealed five to six geologic units corresponding to topsoil, clayey sand, sandy clay, clay/peat, and sand while the 2-D resistivity structure corresponds with the VES result. The borehole log reveals sand layers having an N-value of 22-30 which is indicative of medium-dense, brown (medium to fine) sand with occasional gravels from depth 1.50 - 7.50m. The borehole log information correlates well with the VES/2-D result. For the sand layer which connotes dense, grey (medium to fine) sand with occasional gravels from a depth 7.50 – 15.75m with N-value ranging from 26–30m. The study analysis shows that the proposed building could be placed on the dense sand at depth 7.50 – 15.75m, this, however, should depend on the proposed load, length, and breadth of the proposed building. This study has provided useful information about the subsurface condition for engineering structure and zone suitable for the proposed foundation.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
审稿时长
8 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信