V. Alekseev, I. S. Kolodkin, N. Korovkin, Yuri E. Adamyan, S. Krivosheev
{"title":"雷电冲击下接地参数对瞬态电阻最大值的影响","authors":"V. Alekseev, I. S. Kolodkin, N. Korovkin, Yuri E. Adamyan, S. Krivosheev","doi":"10.1109/EICONRUS.2019.8657075","DOIUrl":null,"url":null,"abstract":"The article discusses the influence of environmental parameters on pulse response of grounding devices. When lightning current flows down, complex physicochemical processes occur in grounds, which result in change in grounding impedance compared to that measured at a frequency of 50 Hz. Change of pulse impedance of grounding devices affects the magnitude of overvoltages arising on protective devices. Based on the results of experimental research and computer modeling, the transient characteristics of grounding devices were determined and the degree of influence of ground parameters on them was analyzed.","PeriodicalId":6748,"journal":{"name":"2019 IEEE Conference of Russian Young Researchers in Electrical and Electronic Engineering (EIConRus)","volume":"46 1","pages":"924-927"},"PeriodicalIF":0.0000,"publicationDate":"2019-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":"{\"title\":\"The Influence of Ground Parameters on the Maximum Value of Transient Resistance Under Lightning Impact\",\"authors\":\"V. Alekseev, I. S. Kolodkin, N. Korovkin, Yuri E. Adamyan, S. Krivosheev\",\"doi\":\"10.1109/EICONRUS.2019.8657075\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The article discusses the influence of environmental parameters on pulse response of grounding devices. When lightning current flows down, complex physicochemical processes occur in grounds, which result in change in grounding impedance compared to that measured at a frequency of 50 Hz. Change of pulse impedance of grounding devices affects the magnitude of overvoltages arising on protective devices. Based on the results of experimental research and computer modeling, the transient characteristics of grounding devices were determined and the degree of influence of ground parameters on them was analyzed.\",\"PeriodicalId\":6748,\"journal\":{\"name\":\"2019 IEEE Conference of Russian Young Researchers in Electrical and Electronic Engineering (EIConRus)\",\"volume\":\"46 1\",\"pages\":\"924-927\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2019 IEEE Conference of Russian Young Researchers in Electrical and Electronic Engineering (EIConRus)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/EICONRUS.2019.8657075\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2019 IEEE Conference of Russian Young Researchers in Electrical and Electronic Engineering (EIConRus)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/EICONRUS.2019.8657075","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
The Influence of Ground Parameters on the Maximum Value of Transient Resistance Under Lightning Impact
The article discusses the influence of environmental parameters on pulse response of grounding devices. When lightning current flows down, complex physicochemical processes occur in grounds, which result in change in grounding impedance compared to that measured at a frequency of 50 Hz. Change of pulse impedance of grounding devices affects the magnitude of overvoltages arising on protective devices. Based on the results of experimental research and computer modeling, the transient characteristics of grounding devices were determined and the degree of influence of ground parameters on them was analyzed.