{"title":"负担得起的快速嗅觉测量阵列:一种新颖的、基于精油的测试,与UPSIT和主观结果测量密切相关","authors":"Jennifer A. Villwock, Jennifer Li, C. Moore, A. Chiu, Kevin J. Sykes","doi":"10.1177/0003489419870833","DOIUrl":null,"url":null,"abstract":"Background: Olfactory dysfunction is an important facet of numerous disease states ranging from sinonasal disease to neurocognitive disorders. Due to expense and/or logistical barriers, objective olfactory testing is not common. We describe the creation of a novel, essential oil-based smell test, Affordable Rapid Olfaction Measurement Array (AROMA), composed at 14 scents at different concentrations and demonstrate correlation of AROMA with the University of Pennsylvania Smell Identification Test (UPSIT), patient age, Sinonasal Outcomes Test (SNOT-22), and perceived loss of smell. Methods: AROMA was developed for point-of-care olfactory testing and compared to the UPSIT, as well as subjective outcome measures as noted above. About 37 healthy controls were prospectively recruited to assess the reliability of AROMA using a test–retest protocol. An additional cohort of 38 participants with sinonasal disease were prospectively recruited to complete the AROMA and UPSIT, and were compared with a cohort of 30 healthy controls. Spearman correlation correlated AROMA and UPSIT results, patient age, SNOT-22, and perceived loss of smell. Results: AROMA demonstrated good test–retest reliability (r = 0.85, P < .001). Spearman’s rho correlation of AROMA to UPSIT was statistically significant at ρ = 0.75 (P < .001). SNOT-22, age, and perceived sense of smell were all significantly correlated with both AROMA (ρ = −0.548, −0.557, −0.642, respectively) and UPSIT (ρ = −0.367, −0.460, −0.552, respectively). Conclusion: AROMA has a strong correlation with UPSIT and may be more strongly correlated with sinonasal outcomes. Additionally, AROMA is reusable; level of odorant is not static; and AROMA can test both odor detection and identification. Level of evidence: 2b","PeriodicalId":8361,"journal":{"name":"Annals of Otology, Rhinology & Laryngology","volume":"EM-22 1","pages":"39 - 45"},"PeriodicalIF":0.0000,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"Affordable Rapid Olfaction Measurement Array: A Novel, Essential Oil-Based Test Strongly Correlated with UPSIT and Subjective Outcome Measures\",\"authors\":\"Jennifer A. Villwock, Jennifer Li, C. Moore, A. Chiu, Kevin J. Sykes\",\"doi\":\"10.1177/0003489419870833\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Background: Olfactory dysfunction is an important facet of numerous disease states ranging from sinonasal disease to neurocognitive disorders. Due to expense and/or logistical barriers, objective olfactory testing is not common. We describe the creation of a novel, essential oil-based smell test, Affordable Rapid Olfaction Measurement Array (AROMA), composed at 14 scents at different concentrations and demonstrate correlation of AROMA with the University of Pennsylvania Smell Identification Test (UPSIT), patient age, Sinonasal Outcomes Test (SNOT-22), and perceived loss of smell. Methods: AROMA was developed for point-of-care olfactory testing and compared to the UPSIT, as well as subjective outcome measures as noted above. About 37 healthy controls were prospectively recruited to assess the reliability of AROMA using a test–retest protocol. An additional cohort of 38 participants with sinonasal disease were prospectively recruited to complete the AROMA and UPSIT, and were compared with a cohort of 30 healthy controls. Spearman correlation correlated AROMA and UPSIT results, patient age, SNOT-22, and perceived loss of smell. Results: AROMA demonstrated good test–retest reliability (r = 0.85, P < .001). Spearman’s rho correlation of AROMA to UPSIT was statistically significant at ρ = 0.75 (P < .001). SNOT-22, age, and perceived sense of smell were all significantly correlated with both AROMA (ρ = −0.548, −0.557, −0.642, respectively) and UPSIT (ρ = −0.367, −0.460, −0.552, respectively). Conclusion: AROMA has a strong correlation with UPSIT and may be more strongly correlated with sinonasal outcomes. Additionally, AROMA is reusable; level of odorant is not static; and AROMA can test both odor detection and identification. Level of evidence: 2b\",\"PeriodicalId\":8361,\"journal\":{\"name\":\"Annals of Otology, Rhinology & Laryngology\",\"volume\":\"EM-22 1\",\"pages\":\"39 - 45\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2020-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Annals of Otology, Rhinology & Laryngology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/0003489419870833\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Otology, Rhinology & Laryngology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/0003489419870833","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

摘要

背景:从鼻窦疾病到神经认知障碍,嗅觉功能障碍是许多疾病状态的一个重要方面。由于费用和/或后勤障碍,客观嗅觉测试并不常见。我们描述了一种新颖的、基于精油的气味测试,可负担的快速嗅觉测量阵列(AROMA),由14种不同浓度的气味组成,并证明了AROMA与宾夕法尼亚大学气味识别测试(UPSIT)、患者年龄、鼻塞预后测试(SNOT-22)和嗅觉感知损失的相关性。方法:AROMA被开发用于即时嗅觉测试,并与UPSIT进行比较,以及如上所述的主观结果测量。前瞻性招募约37名健康对照,采用重测方案评估AROMA的可靠性。另外一组38名患有鼻窦疾病的参与者被前瞻性地招募来完成AROMA和UPSIT,并与30名健康对照者进行比较。Spearman相关性将AROMA和UPSIT结果、患者年龄、SNOT-22和感知到的嗅觉丧失联系起来。结果:AROMA具有良好的重测信度(r = 0.85, P < .001)。AROMA与UPSIT的Spearman相关ρ = 0.75,有统计学意义(P < 0.001)。SNOT-22、年龄和感知嗅觉与AROMA (ρ分别为- 0.548、- 0.557、- 0.642)和UPSIT (ρ分别为- 0.367、- 0.460、- 0.552)均显著相关。结论:AROMA与UPSIT有较强的相关性,可能与鼻窦预后的相关性更强。此外,AROMA是可重复使用的;气味的水平不是静态的;和AROMA可以同时检测和识别气味。证据等级:2b
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Affordable Rapid Olfaction Measurement Array: A Novel, Essential Oil-Based Test Strongly Correlated with UPSIT and Subjective Outcome Measures
Background: Olfactory dysfunction is an important facet of numerous disease states ranging from sinonasal disease to neurocognitive disorders. Due to expense and/or logistical barriers, objective olfactory testing is not common. We describe the creation of a novel, essential oil-based smell test, Affordable Rapid Olfaction Measurement Array (AROMA), composed at 14 scents at different concentrations and demonstrate correlation of AROMA with the University of Pennsylvania Smell Identification Test (UPSIT), patient age, Sinonasal Outcomes Test (SNOT-22), and perceived loss of smell. Methods: AROMA was developed for point-of-care olfactory testing and compared to the UPSIT, as well as subjective outcome measures as noted above. About 37 healthy controls were prospectively recruited to assess the reliability of AROMA using a test–retest protocol. An additional cohort of 38 participants with sinonasal disease were prospectively recruited to complete the AROMA and UPSIT, and were compared with a cohort of 30 healthy controls. Spearman correlation correlated AROMA and UPSIT results, patient age, SNOT-22, and perceived loss of smell. Results: AROMA demonstrated good test–retest reliability (r = 0.85, P < .001). Spearman’s rho correlation of AROMA to UPSIT was statistically significant at ρ = 0.75 (P < .001). SNOT-22, age, and perceived sense of smell were all significantly correlated with both AROMA (ρ = −0.548, −0.557, −0.642, respectively) and UPSIT (ρ = −0.367, −0.460, −0.552, respectively). Conclusion: AROMA has a strong correlation with UPSIT and may be more strongly correlated with sinonasal outcomes. Additionally, AROMA is reusable; level of odorant is not static; and AROMA can test both odor detection and identification. Level of evidence: 2b
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信