{"title":"AHP法在不同工况下SSSC装置优化选址中的应用","authors":"K. Padma, K. Vaisakh","doi":"10.1109/ICICPI.2016.7859704","DOIUrl":null,"url":null,"abstract":"FACTS devices can enable a line to carry its flow close to rating capacity and consequently can improve the power system security even in contingency and over loaded network. An opposition-based modified differential evolution algorithm is proposed to solve the OPF problem under different operating conditions for enhancement of power system performance with a SSSC device. The best location of SSSC device is determined based on AHP method. The effectiveness of the proposed method is demonstrated on IEEE 30-bus test system.","PeriodicalId":6501,"journal":{"name":"2016 International Conference on Intelligent Control Power and Instrumentation (ICICPI)","volume":"529 1","pages":"210-214"},"PeriodicalIF":0.0000,"publicationDate":"2016-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Application of AHP method for optimal location of SSSC device under different operating conditions\",\"authors\":\"K. Padma, K. Vaisakh\",\"doi\":\"10.1109/ICICPI.2016.7859704\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"FACTS devices can enable a line to carry its flow close to rating capacity and consequently can improve the power system security even in contingency and over loaded network. An opposition-based modified differential evolution algorithm is proposed to solve the OPF problem under different operating conditions for enhancement of power system performance with a SSSC device. The best location of SSSC device is determined based on AHP method. The effectiveness of the proposed method is demonstrated on IEEE 30-bus test system.\",\"PeriodicalId\":6501,\"journal\":{\"name\":\"2016 International Conference on Intelligent Control Power and Instrumentation (ICICPI)\",\"volume\":\"529 1\",\"pages\":\"210-214\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 International Conference on Intelligent Control Power and Instrumentation (ICICPI)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/ICICPI.2016.7859704\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 International Conference on Intelligent Control Power and Instrumentation (ICICPI)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICICPI.2016.7859704","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Application of AHP method for optimal location of SSSC device under different operating conditions
FACTS devices can enable a line to carry its flow close to rating capacity and consequently can improve the power system security even in contingency and over loaded network. An opposition-based modified differential evolution algorithm is proposed to solve the OPF problem under different operating conditions for enhancement of power system performance with a SSSC device. The best location of SSSC device is determined based on AHP method. The effectiveness of the proposed method is demonstrated on IEEE 30-bus test system.