两种数字密度计调整方法兼容性的计量评价

Eugênio Benevides dos Santos, E. C. Oliveira
{"title":"两种数字密度计调整方法兼容性的计量评价","authors":"Eugênio Benevides dos Santos, E. C. Oliveira","doi":"10.3390/metrology3020008","DOIUrl":null,"url":null,"abstract":"Brazilian regulation requires the test methods for analysing the shrinkage factor, and the solubility ratio in crude oils must be estimated under the measurement conditions for appropriation. Since these physicochemical parameters depend upon the density, a Brazilian oil company proposed an adapted and more user-friendly methodology for adjusting the digital density meter under high pressure and temperature conditions. This study aimed to evaluate the metrological compatibility of this proposal by comparing it with the fit model presented by a manufacturer of a digital densimeter and with the tabulated reference values of fluid density. Since the density data behaviour presented non-normal distributions, the Wilcoxon signed-rank test showed metrological compatibility between the approaches studied in the pressure range from 0 psi to 1200 psi (8.273709 MPa) and the temperature range from 5 °C to 70 °C.","PeriodicalId":100666,"journal":{"name":"Industrial Metrology","volume":"29 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-04-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Metrological Evaluation of the Compatibility of Two Different Digital Density Meter Adjustment Methods\",\"authors\":\"Eugênio Benevides dos Santos, E. C. Oliveira\",\"doi\":\"10.3390/metrology3020008\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Brazilian regulation requires the test methods for analysing the shrinkage factor, and the solubility ratio in crude oils must be estimated under the measurement conditions for appropriation. Since these physicochemical parameters depend upon the density, a Brazilian oil company proposed an adapted and more user-friendly methodology for adjusting the digital density meter under high pressure and temperature conditions. This study aimed to evaluate the metrological compatibility of this proposal by comparing it with the fit model presented by a manufacturer of a digital densimeter and with the tabulated reference values of fluid density. Since the density data behaviour presented non-normal distributions, the Wilcoxon signed-rank test showed metrological compatibility between the approaches studied in the pressure range from 0 psi to 1200 psi (8.273709 MPa) and the temperature range from 5 °C to 70 °C.\",\"PeriodicalId\":100666,\"journal\":{\"name\":\"Industrial Metrology\",\"volume\":\"29 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-04-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Industrial Metrology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3390/metrology3020008\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Industrial Metrology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/metrology3020008","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

巴西法规要求分析收缩系数的测试方法,并且必须在专用的测量条件下估计原油中的溶解度比。由于这些物理化学参数取决于密度,一家巴西石油公司提出了一种在高压和高温条件下调整数字密度计的适应性和更用户友好的方法。本研究旨在通过将该建议与数字密度计制造商提供的拟合模型以及流体密度的表列参考值进行比较,来评估该建议的计量兼容性。由于密度数据表现为非正态分布,因此Wilcoxon符号秩检验表明,在0 psi至1200 psi (8.273709 MPa)的压力范围和5°C至70°C的温度范围内,所研究的方法具有计量兼容性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Metrological Evaluation of the Compatibility of Two Different Digital Density Meter Adjustment Methods
Brazilian regulation requires the test methods for analysing the shrinkage factor, and the solubility ratio in crude oils must be estimated under the measurement conditions for appropriation. Since these physicochemical parameters depend upon the density, a Brazilian oil company proposed an adapted and more user-friendly methodology for adjusting the digital density meter under high pressure and temperature conditions. This study aimed to evaluate the metrological compatibility of this proposal by comparing it with the fit model presented by a manufacturer of a digital densimeter and with the tabulated reference values of fluid density. Since the density data behaviour presented non-normal distributions, the Wilcoxon signed-rank test showed metrological compatibility between the approaches studied in the pressure range from 0 psi to 1200 psi (8.273709 MPa) and the temperature range from 5 °C to 70 °C.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信