这是一种可靠的检测S. aureus的手段

Ludwig Essers , Klaus Radebold
{"title":"这是一种可靠的检测S. aureus的手段","authors":"Ludwig Essers ,&nbsp;Klaus Radebold","doi":"10.1016/S0172-5599(80)80003-4","DOIUrl":null,"url":null,"abstract":"<div><p>369 staphylococcal strains isolated from clinical material were examined for tubeagglutination with sensitized sheep red cells in a standarized assay to study its reliability for routine identification of <em>S. aureus</em>. Colonies isolated from blood agar plates correlated in 99.5% with the (optimized) coagulase reaction. The test is easily to perform and results can be read after 2 hours, whereas the reference methods coagulase, hyaluronidase and deoxyribonuclease took as much as 24 h. The reliability of these tests is discussed.</p></div>","PeriodicalId":101293,"journal":{"name":"Zentralblatt für Bakteriologie. 1. Abt. Originale A, Medizinische Mikrobiologie, Infektionskrankheiten und Parasitologie","volume":"247 2","pages":"Pages 170-176"},"PeriodicalIF":0.0000,"publicationDate":"1980-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0172-5599(80)80003-4","citationCount":"1","resultStr":"{\"title\":\"Protein-A-Hämagglutinationstest, eine zuverlässige Methode zur schnellen Identifizierung von S. aureus\",\"authors\":\"Ludwig Essers ,&nbsp;Klaus Radebold\",\"doi\":\"10.1016/S0172-5599(80)80003-4\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>369 staphylococcal strains isolated from clinical material were examined for tubeagglutination with sensitized sheep red cells in a standarized assay to study its reliability for routine identification of <em>S. aureus</em>. Colonies isolated from blood agar plates correlated in 99.5% with the (optimized) coagulase reaction. The test is easily to perform and results can be read after 2 hours, whereas the reference methods coagulase, hyaluronidase and deoxyribonuclease took as much as 24 h. The reliability of these tests is discussed.</p></div>\",\"PeriodicalId\":101293,\"journal\":{\"name\":\"Zentralblatt für Bakteriologie. 1. Abt. Originale A, Medizinische Mikrobiologie, Infektionskrankheiten und Parasitologie\",\"volume\":\"247 2\",\"pages\":\"Pages 170-176\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1980-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/S0172-5599(80)80003-4\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Zentralblatt für Bakteriologie. 1. Abt. Originale A, Medizinische Mikrobiologie, Infektionskrankheiten und Parasitologie\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0172559980800034\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Zentralblatt für Bakteriologie. 1. Abt. Originale A, Medizinische Mikrobiologie, Infektionskrankheiten und Parasitologie","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0172559980800034","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

采用标准化试验方法,对从临床材料中分离的369株葡萄球菌进行致敏羊红细胞的管凝集试验,以研究其在常规金黄色葡萄球菌鉴定中的可靠性。从血琼脂平板上分离的菌落与(优化后的)凝固酶反应的相关性为99.5%。该试验易于操作,2小时后即可读取结果,而参考方法凝固酶、透明质酸酶和脱氧核糖核酸酶需要长达24小时。讨论了这些试验的可靠性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Protein-A-Hämagglutinationstest, eine zuverlässige Methode zur schnellen Identifizierung von S. aureus

369 staphylococcal strains isolated from clinical material were examined for tubeagglutination with sensitized sheep red cells in a standarized assay to study its reliability for routine identification of S. aureus. Colonies isolated from blood agar plates correlated in 99.5% with the (optimized) coagulase reaction. The test is easily to perform and results can be read after 2 hours, whereas the reference methods coagulase, hyaluronidase and deoxyribonuclease took as much as 24 h. The reliability of these tests is discussed.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信