基于dbscan -投影法的锂离子电池连接故障检测

Xiaopeng Tang, K. Yao, Boyang Liu, F. Gao
{"title":"基于dbscan -投影法的锂离子电池连接故障检测","authors":"Xiaopeng Tang, K. Yao, Boyang Liu, F. Gao","doi":"10.12783/dteees/iceee2019/31808","DOIUrl":null,"url":null,"abstract":"This paper presents a connection failure detection for a Lithium-ion battery pack when no external vibrations exist. First, the gradient correction method is employed to identify the overall ohmic resistance, which is the summation of the internal and external (contact) resistance. Second, the battery state of health (SOH) is estimated with incremental capacity analysis (ICA) - based method. Third, Density-Based Spatial Clustering of Applications with Noise (DBSCAN) method is applied to diagnose the connection failure by matching the calculated resistance with the estimated SOH. Finally, a linear projection is applied to reduce the method sensitivity to the testing conditions such as different state of charge (SOC). Experiments show that the proposed method can identify the location of the connection failure well in real time.","PeriodicalId":11324,"journal":{"name":"DEStech Transactions on Environment, Energy and Earth Sciences","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2019-10-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Connection Failure Detection for Lithium-ion Batteries Based on DBSCAN-Projection Method\",\"authors\":\"Xiaopeng Tang, K. Yao, Boyang Liu, F. Gao\",\"doi\":\"10.12783/dteees/iceee2019/31808\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a connection failure detection for a Lithium-ion battery pack when no external vibrations exist. First, the gradient correction method is employed to identify the overall ohmic resistance, which is the summation of the internal and external (contact) resistance. Second, the battery state of health (SOH) is estimated with incremental capacity analysis (ICA) - based method. Third, Density-Based Spatial Clustering of Applications with Noise (DBSCAN) method is applied to diagnose the connection failure by matching the calculated resistance with the estimated SOH. Finally, a linear projection is applied to reduce the method sensitivity to the testing conditions such as different state of charge (SOC). Experiments show that the proposed method can identify the location of the connection failure well in real time.\",\"PeriodicalId\":11324,\"journal\":{\"name\":\"DEStech Transactions on Environment, Energy and Earth Sciences\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-10-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"DEStech Transactions on Environment, Energy and Earth Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.12783/dteees/iceee2019/31808\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"DEStech Transactions on Environment, Energy and Earth Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.12783/dteees/iceee2019/31808","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

提出了一种无外部振动情况下锂离子电池组连接故障检测方法。首先,采用梯度校正法识别整体欧姆电阻,即内外(接触)电阻之和。其次,采用基于增量容量分析(ICA)的方法估计电池的健康状态(SOH)。第三,采用基于密度的带噪声应用空间聚类(DBSCAN)方法,将计算的电阻与估计的SOH进行匹配,诊断连接故障。最后,采用线性投影法降低了该方法对不同荷电状态等测试条件的灵敏度。实验表明,该方法能较好地实时识别连接故障位置。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Connection Failure Detection for Lithium-ion Batteries Based on DBSCAN-Projection Method
This paper presents a connection failure detection for a Lithium-ion battery pack when no external vibrations exist. First, the gradient correction method is employed to identify the overall ohmic resistance, which is the summation of the internal and external (contact) resistance. Second, the battery state of health (SOH) is estimated with incremental capacity analysis (ICA) - based method. Third, Density-Based Spatial Clustering of Applications with Noise (DBSCAN) method is applied to diagnose the connection failure by matching the calculated resistance with the estimated SOH. Finally, a linear projection is applied to reduce the method sensitivity to the testing conditions such as different state of charge (SOC). Experiments show that the proposed method can identify the location of the connection failure well in real time.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信