{"title":"光伏微发电对农村低压电网电压质量的影响——谐波和不平衡","authors":"Semih Hurmeydan, A. Rosin, T. Vinnal","doi":"10.1109/PQ.2016.7724096","DOIUrl":null,"url":null,"abstract":"The growing demand for utilization of solar energy and thus increasing number of photovoltaic (PV) systems installed in low voltage (LV) distribution networks has given rise to the studies focusing on the effects of these systems on power quality (PQ) and supply reliability. The aim of this study is to analyze the effects of small-scale PV-system power (P(PV)) generation on voltage quality in a rural LV distribution network in Estonia. In the analysis, which is based on real field measurements, the numerical and graphical methods were used. The correlations between P(PV) generation and the following voltage quality parameters are shown: voltage total harmonic distortion (THDU) and individual odd harmonic components up to order 19 and voltage unbalance.","PeriodicalId":6470,"journal":{"name":"2016 Electric Power Quality and Supply Reliability (PQ)","volume":"73 1","pages":"97-100"},"PeriodicalIF":0.0000,"publicationDate":"2016-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"8","resultStr":"{\"title\":\"Effects of PV microgeneration on rural LV network voltage quality - harmonics and unbalance\",\"authors\":\"Semih Hurmeydan, A. Rosin, T. Vinnal\",\"doi\":\"10.1109/PQ.2016.7724096\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The growing demand for utilization of solar energy and thus increasing number of photovoltaic (PV) systems installed in low voltage (LV) distribution networks has given rise to the studies focusing on the effects of these systems on power quality (PQ) and supply reliability. The aim of this study is to analyze the effects of small-scale PV-system power (P(PV)) generation on voltage quality in a rural LV distribution network in Estonia. In the analysis, which is based on real field measurements, the numerical and graphical methods were used. The correlations between P(PV) generation and the following voltage quality parameters are shown: voltage total harmonic distortion (THDU) and individual odd harmonic components up to order 19 and voltage unbalance.\",\"PeriodicalId\":6470,\"journal\":{\"name\":\"2016 Electric Power Quality and Supply Reliability (PQ)\",\"volume\":\"73 1\",\"pages\":\"97-100\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2016-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"8\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"2016 Electric Power Quality and Supply Reliability (PQ)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/PQ.2016.7724096\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 Electric Power Quality and Supply Reliability (PQ)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/PQ.2016.7724096","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

摘要

随着太阳能利用需求的不断增长,在低压配电网中安装的光伏系统数量不断增加,人们开始关注这些系统对电能质量和供电可靠性的影响。本研究的目的是分析爱沙尼亚农村低压配电网中小型光伏发电对电压质量的影响。在以现场实测数据为基础的分析中,采用了数值法和图解法。P(PV)发电与以下电压质量参数之间的相关性显示:电压总谐波失真(THDU)和个别奇谐波分量高达19阶和电压不平衡。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Effects of PV microgeneration on rural LV network voltage quality - harmonics and unbalance
The growing demand for utilization of solar energy and thus increasing number of photovoltaic (PV) systems installed in low voltage (LV) distribution networks has given rise to the studies focusing on the effects of these systems on power quality (PQ) and supply reliability. The aim of this study is to analyze the effects of small-scale PV-system power (P(PV)) generation on voltage quality in a rural LV distribution network in Estonia. In the analysis, which is based on real field measurements, the numerical and graphical methods were used. The correlations between P(PV) generation and the following voltage quality parameters are shown: voltage total harmonic distortion (THDU) and individual odd harmonic components up to order 19 and voltage unbalance.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信